Lithonia Lighting SB 232 120 GESB

Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

Model: SB 232 120 GESB

1. ആമുഖം

This manual provides instructions for the safe installation, operation, and maintenance of the Lithonia Lighting SB 232 120 GESB Wraparound 2-head Narrow Body T8 Fluorescent Ceiling Fixture. This fixture is designed for general illumination in various indoor settings such as storage rooms, offices, or retail applications. Key features include a hinged design for easy cleaning, an instant-on electronic ballast to eliminate flickering and humming, and a prismatic diffuser for controlled light distribution.

Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

Image 1.1: Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture.

2 സുരക്ഷാ വിവരങ്ങൾ

മുന്നറിയിപ്പ്: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. Improper wiring can result in electric shock or fire.

  • Always turn off the main power supply before attempting any installation, maintenance, or bulb replacement.
  • നിങ്ങൾക്ക് ഇലക്ട്രിക്കൽ വയറിംഗിൽ പരിചയമില്ലെങ്കിൽ യോഗ്യതയുള്ള ഒരു ഇലക്ട്രീഷ്യനെ സമീപിക്കുക.
  • എല്ലാ വയറിംഗ് കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും പ്രാദേശിക ഇലക്ട്രിക്കൽ കോഡുകൾ പാലിക്കുന്നുണ്ടെന്നും ഉറപ്പാക്കുക.
  • ഇൻസ്റ്റാളേഷൻ സമയത്ത് സുരക്ഷാ ഗ്ലാസുകൾ, കയ്യുറകൾ പോലുള്ള ഉചിതമായ വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ ധരിക്കുക.
  • Handle the fixture carefully to avoid sharp edges.
  • ഈ ഉപകരണം ഇൻഡോർ ഉപയോഗത്തിനായി മാത്രം രൂപകൽപ്പന ചെയ്തിട്ടുള്ളതാണ്.

3. പാക്കേജ് ഉള്ളടക്കം

ഇൻസ്റ്റാളേഷൻ ആരംഭിക്കുന്നതിന് മുമ്പ് എല്ലാ ഘടകങ്ങളും നിലവിലുണ്ടെന്ന് ഉറപ്പാക്കുക:

  • 1 x Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture

കുറിപ്പ്: Fluorescent T8 bulbs, mounting hardware (screws/anchors), and wire nuts are NOT included and must be purchased separately.

4 സ്പെസിഫിക്കേഷനുകൾ

ബ്രാൻഡ്ലിത്തോണിയ ലൈറ്റിംഗ്
മോഡൽ നമ്പർSB 232 120 GESB
വാല്യംtage120 വോൾട്ട്
വാട്ട്tage32 Watts (per lamp)
L ൻ്റെ എണ്ണംamps2 (T8 Fluorescent)
ബാലസ്റ്റ് തരംResidential Electronic Ballast
മെറ്റീരിയൽSteel (housing), Acrylic (diffuser)
പൂർത്തിയാക്കുകWhite Enamel
അളവുകൾ (L x W x H)48 ഇഞ്ച് x, 8.5 ഇഞ്ച് x, 2 ഇഞ്ച്
മൗണ്ടിംഗ് തരംSurface Mount, Stem Mount
സർട്ടിഫിക്കേഷനുകൾcUL ലിസ്‌റ്റ് ചെയ്‌തു
Dimensions of Lithonia Lighting SB 232 120 GESB fixture: 48 inches long, 8.5 inches wide, 2 inches high

Image 4.1: Product dimensions of the SB 232 120 GESB fixture.

5. ഇൻസ്റ്റലേഷൻ

Follow these steps for proper installation. Ensure power is disconnected before proceeding.

5.1. തയ്യാറാക്കൽ

  • സർക്യൂട്ട് ബ്രേക്കറിലോ ഫ്യൂസ് ബോക്സിലോ പവർ ഓഫ് ചെയ്യുക.
  • Gather necessary tools: screwdrivers, wire strippers, drill, appropriate mounting hardware (screws/anchors), and wire nuts (all not included).
  • ഫിക്സ്ചർ അൺപാക്ക് ചെയ്ത് എന്തെങ്കിലും കേടുപാടുകൾ ഉണ്ടോ എന്ന് പരിശോധിക്കുക.

5.2. ഫിക്സ്ചർ മൌണ്ട് ചെയ്യുന്നു

  • Determine the desired mounting location on the ceiling for surface mounting or identify points for stem mounting.
  • For surface mounting, align the fixture and mark the drilling points for securing it to the ceiling joists or using appropriate anchors.
  • For stem mounting, the fixture requires a minimum of two single stem hangers (not included).
  • Secure the fixture firmly to the mounting surface using the appropriate hardware. Note that the wire entry tabs are located on the top of the fixture, requiring access from above for wiring.
Diagram showing surface or stem mounting options for the fixture, indicating two lamps and broad light distribution

Image 5.1: Mounting options and features of the fixture.

5.3. വയറിംഗ്

  • Route the electrical supply wires into the fixture's wiring compartment.
  • Connect the supply wires to the fixture's pre-wired connections using wire nuts (not included). Ensure proper polarity (live to live, neutral to neutral, ground to ground).
  • The fixture may feature push-lok connectors for simplified wiring. Ensure wires are fully inserted and secure.
  • Carefully tuck all wires into the wiring compartment and secure any covers.

5.4. Bulb Installation

  • Install two T8 fluorescent bulbs (not included) into the lamp holders by aligning the pins with the sockets and twisting gently until secure.

5.5. ഡിഫ്യൂസർ ഇൻസ്റ്റാളേഷൻ

  • Attach the prismatic acrylic diffuser to the fixture. The hinged design allows it to snap into place or be secured with latches.

6. ഓപ്പറേഷൻ

Once installation is complete and verified, restore power to the circuit. The fixture will illuminate immediately upon activation of the wall switch, thanks to its instant-on electronic ballast, which prevents flickering and humming.

7. പരിപാലനം

Regular maintenance ensures optimal performance and longevity of your fixture.

7.1. വൃത്തിയാക്കൽ

  • വൃത്തിയാക്കുന്നതിന് മുമ്പ് എല്ലായ്പ്പോഴും വൈദ്യുതി വിച്ഛേദിക്കുക.
  • The hinged design of the diffuser allows for easy access. Open the diffuser carefully.
  • Clean the diffuser and the exterior surfaces of the fixture with a soft, damp തുണി.
  • Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or acrylic diffuser.
  • Ensure all parts are dry before restoring power.

7.2. ബൾബ് മാറ്റിസ്ഥാപിക്കൽ

  • Always disconnect power before replacing bulbs.
  • Open the hinged diffuser to access the bulbs.
  • Carefully remove the old T8 fluorescent bulbs by twisting them to disengage from the sockets.
  • Insert new T8 fluorescent bulbs, ensuring the pins are properly aligned with the sockets, and twist gently until secure.
  • Close the diffuser securely.
  • ഫിക്‌ചറിലേക്ക് പവർ പുനഃസ്ഥാപിക്കുക.

8. പ്രശ്‌നപരിഹാരം

If you encounter issues with your fixture, refer to the following troubleshooting guide:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ലൈറ്റ് ഓണാക്കുന്നില്ലവൈദ്യുതി വിതരണം ഇല്ല
തെറ്റായ ബൾബുകൾ
അയഞ്ഞ വയറിംഗ് കണക്ഷൻ
സർക്യൂട്ട് ബ്രേക്കർ/ഫ്യൂസ് പരിശോധിക്കുക
Replace bulbs with known good ones
Inspect and secure all wiring connections (with power off)
Light flickers or humsBulbs not fully seated
Faulty ballast (rare for instant-on)
അയഞ്ഞ വയറിംഗ്
Ensure bulbs are firmly in sockets
If flickering/humming persists, consult an electrician to check ballast
Verify wiring connections are secure (with power off)
അസമമായ പ്രകാശ വിതരണംDiffuser improperly seated
തെറ്റായ ബൾബ് തരം/വാട്ട്tage
Ensure diffuser is correctly installed
Verify T8 bulbs of correct wattagഇ ഉപയോഗിക്കുന്നു

9. വാറൻ്റിയും പിന്തുണയും

This Lithonia Lighting SB 232 120 GESB Wraparound Fluorescent Fixture is backed by a 1 വർഷത്തെ പരിമിതമായ നിർമ്മാതാവിന്റെ വാറന്റി വാങ്ങിയ തീയതി മുതൽ.

This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, accident, misuse, abuse, or unauthorized modifications.

For technical support, warranty claims, or further assistance, please contact Lithonia Lighting customer service. Refer to the official Lithonia Lighting webനിലവിലെ ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾക്കായി സൈറ്റ്.

© 2024 Lithonia Lighting. All rights reserved.

അനുബന്ധ രേഖകൾ - SB 232 120 GESB

പ്രീview Lithonia Lighting OALS10 65F 120 P LP BZ Outdoor Area Light Installation and Safety Manual
Comprehensive installation guide and safety instructions for the Lithonia Lighting OALS10 65F 120 P LP BZ outdoor area light, featuring multilingual support and troubleshooting tips.
പ്രീview Lithonia Lighting Fluorescent UC8 Installation Instructions
This document provides detailed installation instructions for the Lithonia Lighting Fluorescent UC8 fixture. It includes safety warnings, a packing list, step-by-step installation procedures, and troubleshooting guidance.
പ്രീview ലിത്തോണിയ ലൈറ്റിംഗ് എൽഇഡി സുരക്ഷാ ഫ്ലഡ്‌ലൈറ്റ് ഇൻസ്റ്റാളേഷൻ നിർദ്ദേശങ്ങൾ
ലിത്തോണിയ ലൈറ്റിംഗ് LED സെക്യൂരിറ്റി ഫ്ലഡ്‌ലൈറ്റുകൾക്കായുള്ള (OLF സീരീസ്) വിശദമായ ഇൻസ്റ്റാളേഷൻ നിർദ്ദേശങ്ങൾ, സുരക്ഷാ മുൻകരുതലുകൾ, പാക്കിംഗ് ലിസ്റ്റ്, ട്രബിൾഷൂട്ടിംഗ് ഗൈഡ്. OLF 2SH, OLF 2RH, OLF 3RH എന്നീ മോഡൽ നമ്പറുകൾ ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview ലിത്തോണിയ ലൈറ്റിംഗ് എൽഇഡി സുരക്ഷാ ഫ്ലഡ്‌ലൈറ്റ് ഇൻസ്റ്റാളേഷൻ നിർദ്ദേശങ്ങൾ
Installation and troubleshooting guide for Lithonia Lighting LED Security Floodlights, including models OLF 2RH, OLF 2SH, and OLF 3RH series.
പ്രീview Lithonia Lighting L / LA Standard Industrial Fixture Installation Instructions
Installation and safety instructions for Lithonia Lighting L / LA Standard Industrial fixtures. Includes component verification, socket, end plate, and reflector installation steps.
പ്രീview Lithonia Lighting Fluorescent UC8 Installation Instructions and Safety Guide
Detailed installation instructions, safety warnings, parts list, and troubleshooting guide for the Lithonia Lighting Fluorescent UC8 model. Includes essential information for proper setup and operation.