This manual provides comprehensive instructions for the installation, operation, and maintenance of the Airflow Icon 15S Low Voltage Extractor Fan. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

The Airflow Icon 15S is a low voltage (12V DC) axial extractor fan designed for effective ventilation in domestic environments, including bathrooms and cloakrooms. It features a 100mm (4 inch) outlet and an iris shutter mechanism that opens when the fan is active and closes when off, preventing back draughts. The fan can be mounted either on a surface or recessed into a wall or ceiling and operates via a 12V DC transformer. Various optional control modules are available to enhance its functionality.

2 സുരക്ഷാ വിവരങ്ങൾ

WARNING: Electrical installation should only be performed by a qualified electrician in accordance with local wiring regulations.

  • Always disconnect the power supply before installation, maintenance, or servicing.
  • Ensure the fan is correctly earthed if required by local regulations.
  • Do not install the fan where it may be exposed to direct water spray or excessive humidity beyond its IPX4 rating.
  • ഇൻസ്റ്റലേഷൻ ഏരിയയിൽ നിന്ന് കുട്ടികളെയും അനധികൃത വ്യക്തികളെയും അകറ്റി നിർത്തുക.
  • എല്ലാ വയറിംഗ് കണക്ഷനുകളും സുരക്ഷിതവും ശരിയായി ഇൻസുലേറ്റ് ചെയ്തതുമാണെന്ന് ഉറപ്പാക്കുക.
  • Do not obstruct the fan's airflow during operation.
  • ഈ ഉപകരണം, അവരുടെ സുരക്ഷയ്ക്ക് ഉത്തരവാദിയായ ഒരു വ്യക്തി ഉപകരണത്തിൻ്റെ ഉപയോഗത്തെ സംബന്ധിച്ച മേൽനോട്ടമോ നിർദ്ദേശമോ നൽകിയിട്ടില്ലെങ്കിൽ, ശാരീരികമോ ഇന്ദ്രിയപരമോ മാനസികമോ ആയ കഴിവുകൾ കുറഞ്ഞതോ അനുഭവത്തിൻ്റെയും അറിവിൻ്റെയും അഭാവം ഉള്ള വ്യക്തികൾക്ക് (കുട്ടികൾ ഉൾപ്പെടെ) ഉപയോഗിക്കാൻ ഉദ്ദേശിച്ചുള്ളതല്ല.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Airflow Icon 15S features a sleek design with an integrated iris shutter. The fan is designed for discreet integration into various room decors.

Airflow Icon 15S Extractor Fan with Iris Shutter Closed

ചിത്രം 3.1: ഫ്രണ്ട് view of the Airflow Icon 15S fan with the iris shutter closed, showing the smooth, unobtrusive design and the 'AIRFLOW iCON' logo.

Airflow Icon 15S Extractor Fan with Iris Shutter Open

ചിത്രം 3.2: ഫ്രണ്ട് view of the Airflow Icon 15S fan with the iris shutter open, revealing the internal fan blades and grille for ventilation.

Airflow Icon 15S Extractor Fan Side Profile

ചിത്രം 3.3: സൈഡ് പ്രോfile view of the Airflow Icon 15S fan, illustrating its compact depth and the duct connection point.

4 സ്പെസിഫിക്കേഷനുകൾ

Detailed technical specifications for the Airflow Icon 15S fan are provided below. For a visual representation of dimensions and other data, refer to Figure 4.1.

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്എയർ ഫ്ലോ
മോഡലിൻ്റെ പേര്iCON 15S
ഇലക്ട്രിക് ഫാൻ ഡിസൈൻഎക്‌സ്‌ഹോസ്റ്റ് ഫാൻ
പവർ ഉറവിടംCorded Electric (12V DC Transformer)
മുറിയുടെ തരംBathroom, Cloakroom
പ്രത്യേക സവിശേഷതകൾRemote Controlled (with optional module), Water Resistant (IPX4), Timer (with optional module), Silent Operation
ശുപാർശ ചെയ്യുന്ന ഉപയോഗങ്ങൾവായുസഞ്ചാരം
ശബ്ദ നില32.4 ഡെസിബെൽ
വാട്ട്tage6.1 watts (Fan only), 7.5 watts (Total consumption)
എയർ ഫ്ലോ കപ്പാസിറ്റി79 Cubic Meters Per Hour (21.9 Liters Per Second)
വാല്യംtage12 വോൾട്ട് (DC)
ഇനത്തിൻ്റെ ഭാരം1.13 കിലോഗ്രാം (2.48 പൗണ്ട്)
ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾCord (for transformer connection)
ഇൻഡോർ/ഔട്ട്ഡോർ ഉപയോഗംഇൻഡോർ
സ്പെസിഫിക്കേഷൻ മെറ്റ്CE
ഇൻസ്റ്റലേഷൻ തരംWall Mount, Ceiling Mount (Surface or Recessed)
ഉൽപ്പന്ന അളവുകൾ4.27 x 7.76 x 7.76 ഇഞ്ച് (108.5 x 197 x 197 മിമി)
പ്രവേശന സംരക്ഷണ റേറ്റിംഗ്IPX4
പരമാവധി ആംബിയന്റ് താപനില40 °C
Airflow Icon 15S Technical Data, Dimensions, Covers, and Performance Graph

ചിത്രം 4.1: Consolidated technical data for the Airflow Icon 15S, including specifications, available cover colors, detailed dimensions (in mm), and a static pressure vs. airflow performance graph.

5. ഇൻസ്റ്റലേഷൻ

Installation should be carried out by a qualified professional. Ensure the power supply is disconnected before commencing work.

Airflow Icon 15S Wall and Ceiling Installation Diagrams

ചിത്രം 5.1: Diagrams illustrating various installation methods for the Airflow Icon 15S, including recessed and surface mounting on walls and ceilings, along with best practice recommendations for flexible ducting.

5.1 മതിൽ ഇൻസ്റ്റാളേഷൻ

റീസെസ്ഡ് വാൾ മൗണ്ടിംഗ്

  • The iCON 15S requires a 110mm diameter hole through the wall.
  • The hole should be lined with a 100mm internal diameter duct.
  • Secure the fan within the prepared opening using appropriate fixings.

ഉപരിതല മതിൽ മൗണ്ടിംഗ്

  • When surface mounting, use the supplied mounting skirt.
  • The iCON 15S requires a 100mm internal diameter duct for connection.
  • Ensure all vapor barriers are properly restored after installation.

5.2 സീലിംഗ് ഇൻസ്റ്റാളേഷൻ

റീസെസ്ഡ് സീലിംഗ് മൗണ്ടിംഗ്

  • iCON 15S-ന് സീലിംഗിലൂടെ 110mm വ്യാസമുള്ള ഒരു ദ്വാരം ആവശ്യമാണ്.
  • The fan should be fitted into the hole and fixed with screws provided into the support structure.

ഉപരിതല സീലിംഗ് മൗണ്ടിംഗ്

  • When surface mounting, use the supplied mounting skirt.
  • The fan is then fitted into the skirt and secured.
  • For recessed or surface mounting in a ceiling, a plywood support (min. 18mm thick) must be mounted between the ceiling joists. Any fixing screws should be fitted through the plasterboard into the support.

5.3 Ducting Recommendations

  • Where flexible ducting is used, the diameter must be maintained.
  • It is good ventilation practice that the ducting is extended to a minimum of 90% its possible length in order to maintain the best possible airflow.
  • Ensure that flexible duct connections are not overtightened to the spigots.
  • To maximize airflow, rigid ducting should be used where possible.
  • Fan and ducting installation must comply with the requirements of the Domestic Ventilation Compliance Guide and relevant Building Regulations.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The basic Airflow Icon 15S fan operates when power is supplied to its 12V DC transformer, typically controlled by a remote switch (e.g., a light switch). For advanced functionalities, optional plug-in modules are required.

6.1 അടിസ്ഥാന പ്രവർത്തനം

  • When the fan receives power, the iris shutter will open, and the fan will begin to extract air.
  • When power is removed, the fan will stop, and the iris shutter will close, preventing back draughts.

6.2 Operation with Optional Modules

Refer to Section 8, "Optional Modules," for details on specific module functionalities such as pull cord, timer, humidity sensor, and PIR motion detection.

7. പരിപാലനം

Regular cleaning and maintenance will ensure the longevity and efficient operation of your Airflow Icon 15S fan. Always disconnect the power supply before performing any maintenance.

  • പുറം വൃത്തിയാക്കൽ: പുറംഭാഗം തുടയ്ക്കുക casinഗ്രാം വിത്ത് എ സോഫ്റ്റ്, ഡിamp തുണി. ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
  • Cleaning the Iris Shutter and Blades: Carefully open the iris shutter (if possible, or remove the cover as per installation instructions) and gently clean any dust or debris from the shutter mechanism and fan blades using a soft brush or cloth. Ensure no foreign objects obstruct the shutter's movement.
  • പരിശോധന: Periodically check for any signs of damage to the casing, wiring, or fan components. If any damage is found, consult a qualified technician.
  • Do not lubricate any part of the fan.

8 ഓപ്ഷണൽ മൊഡ്യൂളുകൾ

The Airflow Icon 15S fan can be enhanced with various plug-in modules to provide additional control features. These modules are sold separately and are quick and easy to install.

Airflow Icon 15S Optional Modules and Cover Colors

ചിത്രം 8.1: Table detailing available optional modules for the iCON SELV 12V series, including their part numbers and descriptions, as well as optional cover colors for iCON 15S and iCON 30S models.

Available iCON SELV 12V Optional Modules:

ഭാഗം നമ്പർ.മോഡൽവിവരണം
72573603പി.സി.എസ്ചരട് വലിക്കുക (മാനുവൽ ഓൺ/ഓഫ്)
72574204പിസിടിഎസ്വലിക്കുക കോർഡ് ടൈമർ (ടൈമറിൽ 1-30 മിനിറ്റ് പ്രവർത്തിപ്പിക്കുക)
72682307ഡി.ടി.എസ്വൈകിയ ടൈമർ (2 മിനിറ്റ് കാലതാമസം, ടൈമർ 2-45 മിനിറ്റ് പ്രവർത്തിപ്പിക്കുക, ചരട് വലിക്കുക)
72574202എച്ച്.ടി.എസ്ഹ്യുമിഡിറ്റി ടൈമർ (40-90% RH, ടൈമർ 2-45 മിനിറ്റ് പ്രവർത്തിപ്പിക്കുക, ചരട് വലിക്കുക)
72574203പി.ആർ.ടി.എസ്PIR ടൈമർ (മോഷൻ സെൻസർ, ടൈമർ 2-45 മിനിറ്റ് പ്രവർത്തിപ്പിക്കുക)
72574201PRHTSPIR with humidity timer (Motion sensor, 40-90% RH, Run on timer)

9. പ്രശ്‌നപരിഹാരം

If you encounter issues with your Airflow Icon 15S fan, refer to the table below for common problems and their potential solutions. Always disconnect power before inspecting the unit.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ഫാൻ പ്രവർത്തിക്കുന്നില്ലNo power supply; Faulty wiring; Faulty transformer; Faulty module (if installed).Check power supply at the switch; Verify wiring connections; Test transformer output; Replace module if necessary. Consult a qualified electrician.
Iris shutter does not open/close properlyObstruction by dust/debris; Mechanical fault in shutter mechanism.Disconnect power and carefully clean the shutter and surrounding area; If problem persists, contact support.
Reduced airflow/poor extractionObstructed ducting; Dirty fan blades; Incorrect ducting installation.Check ducting for blockages or kinks; Clean fan blades; Ensure ducting meets installation guidelines (e.g., correct diameter, minimal bends).
ഓപ്പറേഷൻ സമയത്ത് അമിതമായ ശബ്ദംLoose mounting; Obstruction in fan blades; Motor issue.Ensure fan is securely mounted; Disconnect power and check for debris in blades; If motor noise, contact support.

10. വാറൻ്റി വിവരങ്ങൾ

The Airflow Icon 15S Low Voltage Extractor Fan is typically supplied with a 3 വർഷത്തെ വാറൻ്റി from the date of purchase, covering manufacturing defects. This warranty does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or normal wear and tear.

Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided at the time of purchase or contact Airflow customer support.

11. ഉപഭോക്തൃ പിന്തുണ

For technical assistance, spare parts, or warranty inquiries, please contact Airflow customer support. Ensure you have your product model (iCON 15S) and proof of purchase available when contacting support.

Airflow Contact Information:
Please refer to the official Airflow webഏറ്റവും പുതിയ കോൺടാക്റ്റ് വിശദാംശങ്ങൾക്ക് സൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ ഉൽപ്പന്ന പാക്കേജിംഗ്.

© 2023 Airflow. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.