T.I.P. 30168

T.I.P. Extrema 400/11 CX Submersible Water Pump Instruction Manual

മോഡൽ: 30168

1. ആമുഖം

The T.I.P. Extrema 400/11 CX is a professional-grade submersible water pump designed for demanding applications. This robust pump is constructed from high-quality stainless steel and cast iron, ensuring durability and reliable performance. It is capable of handling both clean and dirty water, including liquids with solid particles up to 40 mm in size, and can operate with water temperatures up to 90°C for short durations.

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your T.I.P. Extrema 400/11 CX pump. Please read all instructions carefully before use.

T.I.P. Extrema 400/11 CX Submersible Water Pump

Image of the T.I.P. Extrema 400/11 CX submersible water pump, showcasing its stainless steel casing and robust design.

2. സുരക്ഷാ നിർദ്ദേശങ്ങൾ

Always observe the following safety precautions to prevent injury and damage to the pump:

  • ഇലക്ട്രിക്കൽ സുരക്ഷ: Ensure the power supply matches the pump's specifications (230V AC). Always connect the pump to a grounded outlet protected by a residual current device (RCD). Never operate the pump with a damaged power cord or plug. Do not pull the pump by its power cable.
  • ജലത്തിൻ്റെ താപനില: The pump is designed for continuous operation with liquids up to 50°C. For short periods (approx. 4 minutes), it can handle temperatures up to 90°C. Exceeding these limits can damage the pump and void the warranty.
  • നിമജ്ജന ആഴം: Do not exceed the maximum immersion depth of 7 meters.
  • കൈകാര്യം ചെയ്യൽ: Always use the designated handle for lifting and lowering the pump. Never lift or carry the pump by the power cable or discharge hose.
  • കുട്ടികളും വളർത്തുമൃഗങ്ങളും: Keep children and pets away from the operating pump and the area where it is installed.
  • പരിപാലനം: Disconnect the pump from the power supply before performing any maintenance, cleaning, or inspection.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview ഫീച്ചറുകളും

The T.I.P. Extrema 400/11 CX pump is engineered for high performance and durability. Key features include:

  • ഉയർന്ന ഒഴുക്ക് നിരക്ക്: Delivers up to 24,000 liters per hour with a maximum delivery head of 11 meters, ideal for challenging drainage tasks.
  • നീണ്ടുനിൽക്കുന്ന നിർമ്മാണം: Features a high-quality stainless steel and cast iron housing, ensuring maximum durability and reliability even under intensive use.
  • ബഹുമുഖ പ്രയോഗങ്ങൾ: Perfectly suited for construction sites, sewage pits, garden ponds, basement drainage in case of floods, and sewage systems in rural areas.
  • താപനില പ്രതിരോധം: Safely operates with liquids up to 95°C for short periods (approx. 4 minutes), maintaining performance in harsh conditions. Continuous operation up to 50°C.
  • Robust Impeller System: Equipped with a solid vortex impeller system, effective against pump clogging, and capable of handling dirt particles up to 40 mm.
  • യാന്ത്രിക പ്രവർത്തനം: Includes an integrated float switch for automatic on/off control based on water levels.
  • താപ ഓവർലോഡ് സംരക്ഷണം: Features a maintenance-free capacitor motor with thermal overload protection to prevent damage from overheating.
  • ഉയർന്ന നിലവാരമുള്ള ഘടകങ്ങൾ: Hydraulic unit, solid cast iron vortex impeller, motor shaft, cover, and pump base made of stainless steel, along with self-lubricating precision ball bearings.

4. സജ്ജീകരണം

Follow these steps for proper pump setup:

  1. പ്ലേസ്മെൻ്റ്: Position the pump on a stable, level surface in the area to be drained. Ensure it is fully submerged during operation. The maximum immersion depth is 7 meters.
  2. ഡിസ്ചാർജ് ഹോസ് കണക്ഷൻ: Connect a suitable discharge hose to the pump's vertical outlet. The pump includes reducers for various hose diameters:
    • Reducer I: AG 59.61 mm (2 inch) / AG 47.80 mm (1.5 inch) / Hose diameter 51 & 38 mm
    • Reducer II: IG 45.48 mm (1.5 inch) / AG 41.91 mm (1.25 inch)
    • Reducer III: IG 39.59 mm (1.25 inch) / AG 33.25 mm (1 inch) / Hose diameter 32 mm
    എല്ലാ കണക്ഷനുകളും സുരക്ഷിതവും ചോർച്ച രഹിതവുമാണെന്ന് ഉറപ്പാക്കുക.
  3. ഫ്ലോട്ട് സ്വിച്ച് ക്രമീകരണം: Adjust the float switch cable length to set the desired on/off levels for automatic operation. Ensure the float switch can move freely without obstruction.
  4. പവർ കണക്ഷൻ: Plug the 10-meter H07RN-F connection cable into a grounded 230V AC outlet protected by an RCD.
  5. പ്രാരംഭ പരിശോധന: Before starting, ensure the pump is fully submerged and the discharge hose is clear and directed to a suitable drainage point.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The T.I.P. Extrema 400/11 CX operates automatically via its float switch:

  • യാന്ത്രിക മോഡ്: Once connected to power and the float switch is adjusted, the pump will automatically start when the water level rises and lifts the float switch. It will stop when the water level drops and the float switch falls.
  • Manual Operation (if applicable): Some models may allow for manual override by securing the float switch in an 'up' position. Refer to specific product documentation if this feature is desired.
  • ദ്രാവക തരം: The pump is suitable for pumping clear water or dirty water containing heavy impurities up to 40 mm in size.
  • താപനില പരിധി: The maximum continuous liquid temperature is 50°C. For short periods (approximately 4 minutes), the pump can handle liquids up to 90°C. Avoid prolonged operation at higher temperatures.

6. പരിപാലനം

പതിവ് അറ്റകുറ്റപ്പണികൾ നിങ്ങളുടെ പമ്പിന്റെ ദീർഘായുസ്സും ഒപ്റ്റിമൽ പ്രകടനവും ഉറപ്പാക്കുന്നു:

  • വൃത്തിയാക്കൽ: Periodically clean the pump housing and the intake area to remove any debris or blockages. Ensure the float switch is free from obstructions.
  • പരിശോധന: Regularly inspect the power cable for any signs of damage (cuts, abrasions). Check the discharge hose for kinks or blockages.
  • മോട്ടോർ: The capacitor motor is maintenance-free and equipped with thermal overload protection. No user servicing is required for the motor.
  • ബിയറിംഗ്സ്: The precision ball bearings are self-lubricating and do not require additional lubrication.
  • ശൈത്യകാല സംഭരണം: If the pump is not used during freezing temperatures, remove it from the water, clean it thoroughly, and store it in a frost-free environment.

7. പ്രശ്‌നപരിഹാരം

If you encounter issues with your pump, refer to the following troubleshooting guide:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പമ്പ് ആരംഭിക്കുന്നില്ലNo power supply; Float switch not activated; Thermal overload protection triggered; Impeller blocked.Check power connection and RCD; Ensure float switch can move freely and is in 'on' position; Allow pump to cool down; Disconnect power and clear any blockages from the impeller.
കുറഞ്ഞ ഒഴുക്ക് നിരക്ക്Discharge hose kinked or blocked; Intake screen blocked; Pump partially blocked.Check and clear discharge hose; Clean intake screen; Disconnect power and clear internal blockages.
പമ്പ് തുടർച്ചയായി പ്രവർത്തിക്കുന്നുFloat switch stuck in 'on' position; Float switch incorrectly adjusted; Leak in discharge system.Check float switch for free movement; Re-adjust float switch levels; Inspect discharge hose and connections for leaks.
പമ്പ് അസാധാരണമായ ശബ്ദം ഉണ്ടാക്കുന്നുDebris in pump; Worn bearings (unlikely for new pump).Disconnect power and inspect for debris; If noise persists, contact customer support.

If problems persist after following these steps, please contact T.I.P. customer support.

8 സ്പെസിഫിക്കേഷനുകൾ

സ്പെസിഫിക്കേഷൻമൂല്യം
നിർമ്മാതാവ്T.I.P.
മോഡൽ നമ്പർ30168
ഇനത്തിൻ്റെ ഭാരം13.8 കിലോഗ്രാം
ഉൽപ്പന്ന അളവുകൾ (L x W x H)46 x 27 x 20 സെ.മീ
നിറംസ്റ്റെയിൻലെസ്സ് സ്റ്റീൽ
ശൈലിമുങ്ങിപ്പോകാവുന്ന
മെറ്റീരിയൽസ്റ്റെയിൻലെസ്സ് സ്റ്റീൽ
പവർ സോഴ്സ് തരംഎസി/ഡിസി
വാല്യംtage230 വോൾട്ട് (എസി)
വാട്ട്tage1500 വാട്ട്സ്
പരമാവധി ഒഴുക്ക് നിരക്ക്24000 Liters per Hour
Maximum Delivery Head11 മീറ്റർ
പരമാവധി മർദ്ദം1.1 ബാർ
Maximum Immersion Depth7 മീറ്റർ
പരമാവധി കണികാ വലിപ്പം40 മി.മീ
പമ്പ് സിasingസ്റ്റെയിൻലെസ് സ്റ്റീൽ / കാസ്റ്റ് ഇരുമ്പ്
പരമാവധി ദ്രാവക താപനില50°C continuous, 90°C short term (approx. 4 min)
Pressure Connection DiameterIG 87.29 mm (2 inch)
കണക്ഷൻ കേബിൾ10 meters / H07RN-F
ഉൾപ്പെടുത്തിയ ഘടകങ്ങൾExtrema 400/11 CX pump

9. വാറൻ്റിയും പിന്തുണയും

T.I.P. offers a 10-year spare parts guarantee for the Extrema 400/11 CX pump. For convenient spare parts service, please visit the official T.I.P. website or contact their customer support. Ensure you have your model number (30168) and purchase details available when seeking support or ordering parts.

For further assistance or technical inquiries, please refer to the contact information provided on the official T.I.P. webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ ഉൽപ്പന്ന പാക്കേജിംഗ്.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.