This manual provides comprehensive instructions for the installation, operation, and maintenance of your First Alert BRK 7020BSL Hardwired Smoke Detector with LED Strobe Light. This device is designed to provide both audible and visual warnings in the event of smoke or fire, making it particularly beneficial for individuals with hearing impairments. Please read this manual thoroughly before installation and keep it for future reference.
ഉൽപ്പന്ന സവിശേഷതകൾ
- Hardwired with 10-Year Sealed Battery Backup: Ensures continuous operation even during power outages.
- Powerful 177 Candela LED Strobe Light: Provides a bright visual warning, ideal for the hearing impaired.
- Smart Strobe Technology: Distinguishes between smoke/heat and carbon monoxide (CO) dangers with different flash patterns.
- സ്ട്രോബ് സിഗ്നൽ സിൻക്രൊണൈസേഷൻ: When multiple compatible units are installed, all strobes flash in unison for enhanced alert.
- ഫോട്ടോഇലക്ട്രിക് സെൻസർ: Designed to detect smoke from smoldering fires, which typically produce more smoke.
- പരസ്പരം ബന്ധിപ്പിക്കാവുന്നത്: Compatible with other First Alert and BRK smoke, CO, and combination alarms (up to 18 devices, 12 of which can be smoke alarms).
- എളുപ്പമുള്ള ഇൻസ്റ്റാളേഷൻ: Designed for quick and straightforward installation into a standard junction box.
പാക്കേജ് ഉള്ളടക്കം
Your First Alert BRK 7020BSL package should contain the following items:
- First Alert BRK 7020BSL Hardwired Smoke Detector with LED Strobe Light
- മൌണ്ടിംഗ് ബ്രാക്കറ്റ്
- വയറിംഗ് ഹാർനെസ്
- ഇൻസ്റ്റലേഷൻ സ്ക്രൂകളും ആങ്കറുകളും
- നിർദ്ദേശ മാനുവൽ (ഈ പ്രമാണം)
- 1 Lithium Metal Battery (sealed, included)

Image: First Alert BRK 7020BSL smoke detector with its wiring harness, showing the main unit and the separate wiring component.
പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ
Please read and understand all instructions before installing and operating this smoke detector. Failure to follow these instructions may result in property damage, injury, or death.
- മുന്നറിയിപ്പ്: ഇൻസ്റ്റാളേഷൻ ഒരു യോഗ്യതയുള്ള ഇലക്ട്രീഷ്യൻ അല്ലെങ്കിൽ പ്രാദേശിക ഇലക്ട്രിക്കൽ കോഡുകൾക്കനുസൃതമായി നടത്തണം.
- അപായം: Turn off power at the circuit breaker before beginning installation or maintenance.
- Do not paint the smoke detector. Paint can clog the sensing chambers and prevent the unit from operating correctly.
- Test the smoke detector weekly to ensure proper function.
- Replace the unit every 10 years from the date of manufacture, regardless of battery status or apparent functionality.
- This smoke detector is designed for residential use only.
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Follow these steps to properly install your First Alert BRK 7020BSL smoke detector:
- പവർ ഓഫ്: Before starting, ensure the power to the circuit where you will install the alarm is turned off at the main electrical panel.
- Remove Old Alarm (if applicable): Carefully disconnect and remove any existing smoke alarm from the junction box.
- മൗണ്ടിംഗ് ബ്രാക്കറ്റ് ഇൻസ്റ്റലേഷൻ:
- Attach the mounting bracket to the electrical junction box using the provided screws. Ensure it is securely fastened.
- If no junction box is present, use the provided screws and anchors to mount the bracket directly to the ceiling or wall.

ചിത്രം: സൈഡ് പ്രോfile of the First Alert BRK 7020BSL smoke detector, showing its compact design.
- വയറിംഗ് കണക്ഷനുകൾ:
- Connect the white wire from the alarm's wiring harness to the neutral (white) wire from your household wiring using a wire nut.
- Connect the black wire from the alarm's wiring harness to the hot (black) wire from your household wiring using a wire nut.
- If interconnecting multiple alarms, connect the orange wire from the alarm's wiring harness to the interconnect (orange or red) wire from your household wiring. If not interconnecting, cap the orange wire with a wire nut.
- Connect the ground wire from the household wiring to the ground screw on the mounting bracket or junction box.
- ബ്രാക്കറ്റിൽ അലാറം ഘടിപ്പിക്കുക: Plug the wiring harness into the back of the smoke detector. Align the alarm with the mounting bracket and twist clockwise until it locks securely into place.
- പവർ ഓൺ: Restore power to the circuit at the main electrical panel.
- Test Unit: Press and hold the Test/Silence button on the front of the alarm until the alarm sounds and the strobe light flashes. This confirms proper operation.
Video: Official First Alert video demonstrating the installation process for hardwired smoke alarms. This video provides a visual guide to connecting the wiring and mounting the alarm.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed and powered, your First Alert BRK 7020BSL smoke detector operates automatically. Familiarize yourself with its indicators and functions:
- സാധാരണ പ്രവർത്തനം: The green LED indicator will glow continuously, indicating that the unit is receiving AC power. The red LED will flash approximately once every 60 seconds, indicating normal operation and that the battery backup is functioning.
- Alarm Condition (Smoke/Heat): If smoke or heat is detected, the alarm will sound a loud, continuous horn pattern (three beeps, pause, three beeps) and the LED strobe light will flash rapidly.
- Alarm Condition (Carbon Monoxide - if interconnected with CO alarm): If interconnected with a compatible CO alarm and CO is detected, the alarm will sound a distinct horn pattern (four quick beeps, pause, four quick beeps) and the LED strobe light will flash in a specific pattern to indicate CO.
- ടെസ്റ്റ്/സൈലൻസ് ബട്ടൺ:
- Press and hold to test the alarm's functionality.
- Press briefly to silence nuisance alarms for approximately 10 minutes. The strobe light will continue to flash during the silence period.
- കുറഞ്ഞ ബാറ്ററി മുന്നറിയിപ്പ്: The unit will chirp approximately once every minute, and the red LED will flash, indicating that the sealed 10-year battery is nearing the end of its life. The entire unit must be replaced.

ചിത്രം: മുൻഭാഗം view of the First Alert BRK 7020BSL smoke detector, highlighting the test/silence button and the LED strobe light.
മെയിൻ്റനൻസ്
Regular maintenance ensures your smoke detector remains in optimal working condition.
- പ്രതിവാര പരിശോധന: Press and hold the Test/Silence button until the alarm sounds and the strobe flashes. This verifies the electronic circuitry, horn, and battery are working.
- പ്രതിമാസ വൃത്തിയാക്കൽ: Vacuum the cover of the smoke detector with a soft brush attachment to remove dust and debris. Do not use water or cleaning solvents.
- ബാറ്ററി: The unit features a sealed 10-year lithium metal battery. This battery is not replaceable. When the low battery warning sounds (chirping every minute), the entire unit must be replaced.
- യൂണിറ്റ് മാറ്റിസ്ഥാപിക്കൽ: Replace the entire smoke detector unit every 10 years from the date of manufacture. The manufacture date is printed on the back of the unit.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Alarm sounds frequently without apparent smoke. | Nuisance alarm due to cooking fumes, steam, or dust. | Press the Test/Silence button to temporarily silence. Clean the alarm monthly. Relocate if nuisance alarms persist. |
| Alarm chirps once every minute. | കുറഞ്ഞ ബാറ്ററി മുന്നറിയിപ്പ്. | The sealed 10-year battery is at the end of its life. Replace the entire smoke detector unit. |
| പരിശോധനയ്ക്കിടെ അലാറം മുഴങ്ങുന്നില്ല. | No power, faulty unit, or dead battery. | Ensure AC power is on. Check wiring connections. If chirping, replace the unit. If no power or chirping, replace the unit. |
| Strobe light does not flash during alarm. | Faulty strobe light or unit. | Replace the entire smoke detector unit. |
| Alarm is past its 10-year lifespan. | End-of-life for the unit. | Replace the entire smoke detector unit immediately. |
സ്പെസിഫിക്കേഷനുകൾ
| മോഡൽ നമ്പർ | BRK 7020BSL |
| പവർ ഉറവിടം | 120V AC Hardwired with Sealed 10-Year Lithium Metal Battery Backup |
| സെൻസർ തരം | ഫോട്ടോഇലക്ട്രിക് |
| Strobe Light Output | 177 Candela (LED) |
| അലാറം ഉച്ചത്തിലുള്ള ശബ്ദം | 85 അടിയിൽ 10 ഡി.ബി |
| പ്രവർത്തന താപനില | 40°F (4.4°C) മുതൽ 100°F (37.8°C) |
| പ്രവർത്തന ഹ്യുമിഡിറ്റി | 10% മുതൽ 95% വരെ ആപേക്ഷിക ആർദ്രത (കണ്ടൻസിങ് അല്ലാത്തത്) |
| അളവുകൾ | 5.2" Diameter x 2.3" Depth |
| ഭാരം | ഏകദേശം 13.8 ഔൺസ് |
| പരസ്പരം ബന്ധിപ്പിക്കുന്നതിനുള്ള കഴിവ് | Up to 18 compatible devices (12 smoke alarms) |
വാറൻ്റിയും പിന്തുണയും
വാറൻ്റി വിവരങ്ങൾ: First Alert warrants this product to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase. This warranty extends to the original retail purchaser only. Proof of original sales receipt is required for warranty claims. This warranty does not cover damage resulting from accident, misuse, abuse, lack of reasonable care of the product, or any other use not in accordance with the instructions. For full warranty details, please refer to the documentation included with your product or visit the official First Alert webസൈറ്റ്.
ഉപഭോക്തൃ പിന്തുണ: For technical assistance, troubleshooting, or general inquiries, please contact First Alert customer support. Contact information can typically be found on the product packaging or the official First Alert website. Please have your model number (BRK 7020BSL) and date of purchase available when contacting support.