This manual provides essential information for the safe and effective use of your ELKRON SAFT LSH 20 Lithium Batteries. These primary lithium-thionyl chloride batteries, rated at 3.6V and 13Ah, are specifically designed for compatibility with various ELKRON wireless alarm systems, including models such as WL31, HP30WL, UWL31 central units, and UPH30WL outdoor sirens. Please read this manual thoroughly before installation and operation.

2 സുരക്ഷാ വിവരങ്ങൾ

Observe the following safety precautions to prevent injury or damage to your equipment:

  • റീചാർജ് ചെയ്യരുത്: These are primary (non-rechargeable) batteries. Attempting to recharge them may cause leakage, fire, or explosion.
  • ശരിയായ ധ്രുവീകരണം: Always install batteries with the correct polarity (+ and -) as indicated on the battery and the device. Incorrect installation can damage the device.
  • ഷോർട്ട് സർക്യൂട്ടുകൾ ഒഴിവാക്കുക: Do not short-circuit the battery terminals. This can lead to excessive heat, fire, or explosion.
  • താപനില എക്സ്പോഷർ: Do not expose batteries to extreme temperatures (high or low), direct sunlight, or fire.
  • നീക്കം ചെയ്യൽ: Dispose of used batteries according to local regulations. Do not dispose of batteries in household waste or fire. The crossed-out wheeled bin symbol indicates separate collection for electrical and electronic equipment.
  • കുട്ടികൾക്ക് ലഭ്യമാകാതെ സൂക്ഷിക്കുക: Batteries can be a choking hazard and contain hazardous materials.
  • ഡിസ്അസംബ്ലിംഗ് ചെയ്യരുത്: Do not attempt to open, puncture, or modify the battery.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The ELKRON SAFT LSH 20 battery is a high-performance lithium-thionyl chloride cell designed for long-term power in critical applications such as alarm systems. It offers a stable voltage output and high energy density.

ELKRON SAFT LSH 20 Lithium Battery with connector

This image displays the ELKRON SAFT LSH 20 lithium battery, highlighting its cylindrical shape and the attached two-pin connector, which is used for connecting to compatible alarm systems.

പ്രധാന സവിശേഷതകൾ:

  • വാല്യംtage: 3.6 വോൾട്ട്
  • ശേഷി: 13 Ampമുൻ മണിക്കൂറുകൾ (ആഹ്)
  • രസതന്ത്രം: Primary Lithium-Thionyl Chloride
  • അളവുകൾ: Approximately 61mm (height) x 33mm (diameter)
  • അനുയോജ്യത: Designed for ELKRON wireless alarm systems (e.g., UWL31 central unit, UPH30WL outdoor siren) and Silentron systems (e.g., WL31, HP30WL).

4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Follow these steps to install the batteries in your compatible ELKRON alarm system:

  1. പവർ ഓഫ് സിസ്റ്റം: Before beginning, ensure your ELKRON alarm system or device is completely powered off and disconnected from any external power sources.
  2. ബാറ്ററി കമ്പാർട്ട്മെന്റ് കണ്ടെത്തുക: Refer to your ELKRON device's specific manual to locate and open the battery compartment.
  3. Remove Old Batteries (if applicable): If replacing existing batteries, carefully remove them. Note their orientation for correct installation of the new batteries. Dispose of old batteries responsibly.
  4. പുതിയ ബാറ്ററികൾ ചേർക്കുക: Insert the new ELKRON SAFT LSH 20 batteries, paying close attention to the polarity markings (+ and -) inside the compartment. Ensure the connector (if present) is properly seated.
  5. Quantity Requirement: Note that ELKRON wireless central units and outdoor sirens typically require the installation of a pair of these batteries for proper operation.
  6. സുരക്ഷിത കമ്പാർട്ട്മെന്റ്: ബാറ്ററി കമ്പാർട്ട്മെന്റ് കവർ അടച്ച് സുരക്ഷിതമാക്കുക.
  7. പവർ ഓണും ടെസ്റ്റും: Reconnect your alarm system to its power source and power it on. Perform a system test as per your alarm system's instructions to ensure proper functionality.
ELKRON SAFT LSH 20 Lithium Battery with connecting wires

A view of the ELKRON SAFT LSH 20 lithium battery, showing the red and black connecting wires extending from its terminal, ready for installation into a device.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Once correctly installed, the ELKRON SAFT LSH 20 batteries will provide power to your compatible alarm system. These batteries are designed for long-term, reliable performance. There are no specific operating steps for the batteries themselves beyond proper installation.

  • The batteries will continuously power the device until their charge is depleted.
  • Monitor your alarm system's display or indicators for any low battery warnings.
  • When a low battery warning appears, replace the batteries promptly to ensure uninterrupted security.

6. പരിപാലനം

Minimal maintenance is required for these batteries:

  • പതിവ് പരിശോധനകൾ: Periodically check your alarm system for low battery indicators.
  • മാറ്റിസ്ഥാപിക്കൽ: Replace batteries as a pair when the system indicates low power. Always use new, compatible ELKRON SAFT LSH 20 batteries.
  • കോൺടാക്റ്റുകൾ വൃത്തിയാക്കുക: Ensure battery contacts within the device are clean and free from corrosion. If necessary, gently clean them with a dry cloth.
  • സംഭരണം: ഉപയോഗിക്കാത്ത ബാറ്ററികൾ അവയുടെ യഥാർത്ഥ പാക്കേജിംഗിൽ തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് സൂക്ഷിക്കുക, നേരിട്ടുള്ള സൂര്യപ്രകാശവും ഉയർന്ന താപനിലയും ഏൽക്കുന്നതിൽ നിന്ന് അകറ്റി നിർത്തുക.

7. പ്രശ്‌നപരിഹാരം

If you encounter issues after installing your batteries, consider the following:

  • സിസ്റ്റം ഓണാക്കുന്നില്ല:
    • Verify that the batteries are inserted with the correct polarity.
    • ബാറ്ററി കമ്പാർട്ട്മെൻ്റ് സുരക്ഷിതമായി അടച്ചിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക.
    • Confirm that the alarm system's main power switch is in the 'ON' position.
    • Check if the batteries are new and not depleted.
  • ഹ്രസ്വ ബാറ്ററി ലൈഫ്:
    • Ensure you are using genuine ELKRON SAFT LSH 20 batteries.
    • Consult your alarm system's manual for potential system faults that might cause excessive power drain.
    • Verify that the batteries were stored correctly before use.
  • ഇടയ്ക്കിടെയുള്ള പ്രവർത്തനം:
    • Check for loose connections within the battery compartment.
    • Ensure battery contacts are clean and free from debris.

If problems persist, refer to your ELKRON alarm system's specific troubleshooting guide or contact ELKRON customer support.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്എൽക്രോൺ
നിർമ്മാതാവ്സഫ്ത്
മോഡലിൻ്റെ പേര്LSH 20
ബാറ്ററി തരംPrimary Lithium-Thionyl Chloride
വാല്യംtage3.6 വോൾട്ട്
ശേഷി13 Ampമുൻ മണിക്കൂറുകൾ (ആഹ്)
അളവുകൾ (ഏകദേശം)61mm (ഉയരം) x 33mm (വ്യാസം)
Number of Batteries (in pack)2
പുനരുപയോഗംറീചാർജ് ചെയ്യാനാകില്ല
സർട്ടിഫിക്കേഷനുകൾCE Mark, Crossed-out Wheeled Bin Symbol

9. വാറൻ്റിയും പിന്തുണയും

For warranty information or technical support regarding your ELKRON SAFT LSH 20 batteries, please refer to the documentation provided with your ELKRON alarm system or contact the retailer from whom you purchased the product. You may also visit the official ELKRON webഉപഭോക്തൃ സേവന കോൺടാക്റ്റ് വിശദാംശങ്ങൾക്കായുള്ള സൈറ്റ്.

© 2024 ELKRON. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.