1. ഉൽപ്പന്നം കഴിഞ്ഞുview
The GATEXPERT AT1350 Automatic Sliding Gate Opener Kit is designed for reliable and secure operation of sliding gates. This system includes a powerful 110V AC motor capable of handling gates up to 1350lb in weight and 40ft in length. It features remote control operation, an infrared safety sensor, and adjustable automatic close functions to enhance convenience and security.


2 സുരക്ഷാ വിവരങ്ങൾ
Please read and understand all safety warnings and instructions before installation and operation. Failure to follow these instructions may result in serious injury or property damage.
- Ensure the motor is disconnected from power before performing any maintenance or installation.
- പ്രവർത്തന സമയത്ത് കുട്ടികളെയും വളർത്തുമൃഗങ്ങളെയും ഗേറ്റ് ഏരിയയിൽ നിന്ന് അകറ്റി നിർത്തുക.
- The infrared sensor is crucial for safety; ensure it is correctly installed and functioning to prevent the gate from closing on obstructions.
- If the motor operates continuously for more than 15 minutes and reaches 120℃, it will automatically stop for safety.
3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Proper installation is critical for the safe and efficient operation of your gate opener. It is recommended to watch the official installation video for a comprehensive guide.
3.1. അൺബോക്സിംഗും ഘടക പരിശോധനയും
Carefully unbox all components and verify that all parts listed in the user manual are present and undamaged. Refer to the package contents image for verification.

Video 3.1: GATEXPERT AT1350/AT1800 Sliding Gate Opener Installation Guide. This video provides a step-by-step visual walkthrough of the installation process, from unboxing to final setup.
3.2. Mounting Base Assembly and Installation
Assemble the mounting base components as shown. The 4 foundation bolts need to be pre-buried in concrete for a secure installation. Ensure the base is level and stable before mounting the main unit.


3.3. ചെയിൻ ഇൻസ്റ്റലേഷൻ
Attach the chain to the gate and the opener's sprocket. Ensure the chain is taut but not overly tight, allowing for smooth movement. If the provided 20ft chain is not long enough, additional chain can be purchased.
- Choose the suitable chain connecting plate and screws (round/square) based on your gate's design.
- Connect the chain to the tie rod.
- Adjust the length and fix the tie rod securely.
- Unlock the gate opener using the manual release key to allow free movement of the gate during chain adjustment.
- Push the gate by hand to test if it moves smoothly along the track.
- Install the sprocket cover after chain installation.
3.4. Magnet Installation
The magnetic limit switches control the gate's open and close positions. Proper placement is crucial for correct operation.
- Choose the suitable magnetic limit switch block according to your gate structure.
- For the close limit magnet position, the height between the magnet and the chain should be approximately 42mm (1.65 inches).
- For the open limit magnet position, the height between the magnet and the chain should be approximately 104mm (4.09 inches).
3.5. Power Line Installation
Connect the power line to the control board. The power line needs to be prepared by the customer according to local electrical codes and safety standards.

3.6. Infrared Sensor Connection
The infrared sensor provides an essential safety feature, preventing the gate from closing if an obstruction is detected. The wires for the infrared sensor need to be prepared by the customer.
- Connect the infrared sensor wires to the designated terminals on the control board.
- Remove any short wire jumpers from the infrared sensor terminals on the control board if present.
- Ensure the sensors are aligned correctly across the gate's path.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
4.1. വിദൂര നിയന്ത്രണ പ്രവർത്തനം
The gate opener comes with pre-learned remote controls. Up to 25 remote controls can be learned by the system.
- Pressing a single button on the remote control will cyclically control the main engine: OPEN/STOP/CLOSE/STOP.
- To learn a new remote control:
- Press the learning button AN1 on the control board; the indicator light LED2 will turn on.
- Press the same button on the remote control twice. The LED2 light will flash repeatedly and then turn off, indicating successful learning.
- To delete all learned remote controls:
- Press the learning button AN1 (the LED light will be on).
- Hold the button until the light turns off. All remote controls are now deleted.
Video 4.1: GATEXPERT Remote Control Learning/Deleting. This video demonstrates how to program and erase remote controls for the gate opener.
4.2. Automatic Close Function
The system allows for setting an automatic close time after the gate opens. Available settings are 12s, 24s, 36s, or no automatic close function.
- Refer to the control board's specific settings for adjusting the automatic close timer.
5. പരിപാലനം
Regular maintenance ensures the longevity and optimal performance of your GATEXPERT gate opener.
- പ്രതിമാസ: Inspect the gate and opener for any loose fasteners, worn parts, or obstructions. Clean the chain and apply a suitable lubricant to ensure smooth operation.
- ത്രൈമാസിക: Check the alignment of the infrared safety sensors. Test the safety reversal mechanism by placing an object in the gate's path during closing to ensure it reverses.
- വാർഷികം: ഇലക്ട്രിക്കൽ കണക്ഷനുകളും മോട്ടോർ പ്രകടനവും ഉൾപ്പെടെ മുഴുവൻ സിസ്റ്റവും പരിശോധിക്കാൻ ഒരു യോഗ്യതയുള്ള ടെക്നീഷ്യനെ ഏൽപ്പിക്കുക.
6. പ്രശ്നപരിഹാരം
This section provides solutions to common issues you might encounter with your gate opener.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ഗേറ്റ് റിമോട്ടിനോട് പ്രതികരിക്കുന്നില്ല. | Remote battery low/dead; remote not programmed; power issue. | Replace remote battery; re-program remote (refer to Section 4.1); check power supply to opener. |
| ഗേറ്റ് അപ്രതീക്ഷിതമായി നിൽക്കുകയോ പിന്നോട്ട് മാറുകയോ ചെയ്യുന്നു. | Infrared sensor obstructed/misaligned; excessive friction on gate. | Clear obstruction from sensor path; realign sensors; lubricate gate rollers/track. |
| മോട്ടോർ ഓടുന്നു, പക്ഷേ ഗേറ്റ് അനങ്ങുന്നില്ല. | Manual release engaged; chain disconnected/broken. | Disengage manual release; inspect and reattach/replace chain. |
| Gate does not fully open or close. | Limit switch magnets incorrectly positioned. | Adjust the position of the open/close limit magnets (refer to Section 3.4). |
If you encounter problems not listed here or if the suggested solutions do not resolve the issue, please contact GATEXPERT customer support for assistance.
7 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| നിർമ്മാതാവ് | ഗേറ്റ് എക്സ്പർട്ട് |
| ഇനത്തിൻ്റെ ഭാരം | 35.1 പൗണ്ട് |
| ഉൽപ്പന്ന അളവുകൾ | 11.81 x 8.74 x 19.68 ഇഞ്ച് |
| മാതൃരാജ്യം | ചൈന |
| ഇനം മോഡൽ നമ്പർ | AT1350 |
| വലിപ്പം | AT1350 |
| നിറം | നീല |
| ശൈലി | AT1350 Sliding Gate Opener |
| മെറ്റീരിയൽ | എബിഎസ് |
| പവർ ഉറവിടം | AC |
| വാല്യംtage | 110 വോൾട്ട് |
| ഇൻസ്റ്റലേഷൻ രീതി | According to the instructions |
| ഇനത്തിൻ്റെ പാക്കേജ് അളവ് | 1 |
| താപനില പരിധി | -4°F~+158°F Degrees Fahrenheit |
| ശബ്ദ നില | 56 ഡി.ബി |
| സ്റ്റൈൽ സ്വിച്ചുചെയ്യുക | ബട്ടൺ അമർത്തുക |
| പ്രത്യേക സവിശേഷതകൾ | ഇൻസ്റ്റാൾ ചെയ്യാൻ എളുപ്പമാണ് |
8. വാറൻ്റിയും പിന്തുണയും
GATEXPERT provides a standard warranty for its products. For specific warranty details, please refer to the warranty card included in your product packaging or visit the official GATEXPERT webസൈറ്റ്.
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact GATEXPERT customer service:
- ഇമെയിൽ: support@gatexpert.com (exampലെ)
- ഫോൺ: 1-800-XXX-XXXX (ഉദാ.ampലെ)
- Webസൈറ്റ്: ആമസോണിലെ GATEXPERT സ്റ്റോർ സന്ദർശിക്കുക
When contacting support, please have your product model number (AT1350) and purchase date available.