1. ആമുഖം
The OWON SDS1104 is a 4-channel digital storage oscilloscope designed for high accuracy and performance in various electrical testing and measurement applications. It features a 100MHz bandwidth and a 1GS/s sample rate, making it suitable for detailed waveform analysis.
This manual provides essential information for the proper setup, operation, and maintenance of your SDS1104 oscilloscope. Please read it thoroughly before using the device.

ചിത്രം 1.1: മുൻഭാഗം view of the OWON SDS1104 Digital Oscilloscope.
2 പ്രധാന സവിശേഷതകൾ
- ബാൻഡ്വിഡ്ത്ത്: 100MHz with 4 independent channels.
- Sample നിരക്ക്: Up to 1GS/s real-time sample നിരക്ക്.
- റെക്കോർഡ് ദൈർഘ്യം: 40M record length for detailed signal capture.
- വേവ്ഫോം പുതുക്കൽ നിരക്ക്: 45,000 wfms/s for quick observation of signal changes.
- ഡിസ്പ്ലേ: 8-inch 800x600 high-resolution LCD for clear waveform display.
- കണക്റ്റിവിറ്റി: SCPI and LabVIEW supported for remote control and data analysis.
- Trigger Functions: Multi-trigger options including Edge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, RS232, CAN (optional).
- യാന്ത്രിക അളവുകൾ: Built-in functions for 39 types of automatic measurements.

ചിത്രം 2.1: ഓവർview of key features for the SDS1000 series, including 100MHz bandwidth, 4 channels, 1GS/s sample rate, ultra-thin body, 7-inch high resolution LCD, and SCPI/LabVIEW പിന്തുണ.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview നിയന്ത്രണങ്ങളും
3.1 ഫ്രണ്ട് പാനൽ
The front panel of the SDS1104 features the display, control knobs, function buttons, and input channels. Understanding the layout is crucial for efficient operation.

Figure 3.1: Labeled front panel of the SDS1104, showing the 7-inch high resolution LCD, menu selection buttons, multipurpose knob, common function shortcut keys, horizontal control system, trigger system, copy key, vertical control system, signal input channels (CH1-CH4), USB Host port, and power on/off button.
- ഡിസ്പ്ലേ: 7-inch high resolution LCD (800x480 pixels) for waveform visualization.
- Menu Selection Buttons: Navigate through on-screen menus.
- മൾട്ടിപർപ്പസ് നോബ്: Adjust various parameters and settings.
- Common Function Shortcut Keys: Quick access to frequently used functions.
- Horizontal Control System: Adjust time base and horizontal position.
- ട്രിഗർ സിസ്റ്റം: Control trigger level, mode, and type.
- Copy Key: Quickly save or copy screen content.
- Vertical Control System: Adjust vertical scale (Volts/Div) and position for each channel.
- Signal Input Channels (CH1-CH4): BNC connectors for probe input.
- USB ഹോസ്റ്റ് പോർട്ട്: USB സംഭരണ ഉപകരണങ്ങൾ ബന്ധിപ്പിക്കുന്നതിന്.
- പവർ ഓൺ/ഓഫ്: പ്രധാന പവർ സ്വിച്ച്.
3.2 Rear Panel and Side Connections
The rear and side panels house additional ports and features for connectivity and stability.

ചിത്രം 3.2: പിൻഭാഗം view of the SDS1104, highlighting the USB Device port, handle, and foot stools for tilt adjustment.
- USB ഉപകരണ പോർട്ട്: Connects the oscilloscope to a computer for data transfer and remote control.
- കൈകാര്യം ചെയ്യുക: എളുപ്പമുള്ള പോർട്ടബിലിറ്റിക്ക്.
- Foot Stools: Adjustable feet to tilt the oscilloscope for better viewകോണുകൾ.
4. സജ്ജീകരണവും പ്രാരംഭ പ്രവർത്തനവും
4.1 അൺപാക്കിംഗും പരിശോധനയും
Upon receiving your SDS1104, carefully unpack all components and inspect for any signs of damage. Retain the packaging for future transport or storage.

Figure 4.1: Contents of the SDS1000 package, including the SDS1000 unit, four probes, USB cable, probe adjustment tool, power cord, and a CD-ROM with quick guide.
സ്റ്റാൻഡേർഡ് പാക്കേജിൽ ഇവ ഉൾപ്പെടുന്നു:
- SDS1104 Oscilloscope Unit
- അന്വേഷണം x 4
- USB കേബിൾ
- Probe Adjustment Tool
- പവർ കോർഡ്
- CD-ROM and Quick Guide
4.2 പവർ കണക്ഷൻ
Connect the supplied power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100V - 240V AC, 50/60Hz).
4.3 പ്രോബ് കണക്ഷനും നഷ്ടപരിഹാരവും
Connect the oscilloscope probes to the BNC input connectors (CH1-CH4) on the front panel. It is recommended to compensate the probes before making critical measurements to ensure accurate readings.
- Connect the probe to CH1.
- Connect the probe tip to the probe compensation signal output (usually a square wave test point on the front panel).
- Adjust the probe compensation screw (on the probe body) until a flat-top square wave is displayed on the screen.
5. ഓസിലോസ്കോപ്പ് പ്രവർത്തിപ്പിക്കൽ
5.1 അടിസ്ഥാന തരംഗരൂപ പ്രദർശനം
After power-on, press the ഓട്ടോ button to automatically adjust the vertical and horizontal settings for a stable waveform display. Use the vertical (Volts/Div) and horizontal (Time/Div) knobs to fine-tune the display.
5.2 ഓട്ടോമാറ്റിക് അളവുകൾ
The SDS1104 offers 39 types of automatic measurements, providing quick and accurate analysis of waveform parameters.

Figure 5.1: Screen showing built-in 39 types of auto measurements and the FFT spectrum analysis function. Measurements include Max, Min, Pk-Pk, RMS, Mean, Frequency, Period, Rise Time, Fall Time, and more. The FFT function supports Hamming, Hanning, Blackman, Rectangle, Kaiser, and Bartlett windows.
To access automatic measurements, press the അളക്കുക button. You can select various parameters such as Period, Frequency, Mean, PK-PK, RMS, Max, Min, Rise Time, Fall Time, etc.
5.3 Cursor and Zoom Functions
The oscilloscope provides auto cursor and waveform zoom functions for detailed analysis of specific waveform sections.

Figure 5.2: Display illustrating the Auto Cursor function for measuring differences between two points on a waveform, and the Waveform Zoom function for enlarging specific areas of the waveform for detailed observation.
- Auto Cursor: Automatically places cursors to measure parameters like voltage വ്യത്യാസം (ΔV) ഉം സമയ വ്യത്യാസം (ΔT) ഉം.
- Waveform Zoom: Enlarge a specific portion of the waveform for closer inspection.
5.4 Waveform Storage and Math Functions
The SDS1104 allows saving waveforms and performing mathematical operations on them.

Figure 5.3: Screen demonstrating the Waveform Storage function, allowing up to 16 sets of waveforms to be saved and compared, and the Waveform Math Function, which includes operations like +, -, ×, /, FFT, and invert.
- Waveform Storage: Save up to 16 sets of waveforms to internal memory or a USB disk for later recall and analysis.
- Waveform Math: Perform operations such as addition, subtraction, multiplication, division, FFT (Fast Fourier Transform), and inversion on waveforms.
5.5 PC Communication
The oscilloscope can be connected to a host computer for remote control, data logging, and advanced analysis using SCPI commands or LabVIEW സോഫ്റ്റ്വെയർ.

Figure 5.4: Illustration of the SDS1104 communicating with a computer via the supplied USB cable, supporting SCPI and LabVIEW communication functions.
Use the provided USB cable to connect the oscilloscope's USB Device port to your computer. Install the necessary drivers and software (available on the included CD-ROM or OWON's website) to establish communication.
6. പരിപാലനം
Proper maintenance ensures the longevity and accuracy of your SDS1104 oscilloscope.
- വൃത്തിയാക്കൽ: ഒരു സോഫ്റ്റ് ഉപയോഗിക്കുക, ഡിamp cloth to clean the exterior of the oscilloscope. Do not use abrasive cleaners or solvents. Ensure the device is powered off and unplugged before cleaning.
- സംഭരണം: ഉപയോഗത്തിലില്ലാത്തപ്പോൾ, ഓസിലോസ്കോപ്പ് വരണ്ടതും പൊടിയില്ലാത്തതുമായ അന്തരീക്ഷത്തിൽ സൂക്ഷിക്കുക, നേരിട്ടുള്ള സൂര്യപ്രകാശത്തിൽ നിന്നും കടുത്ത താപനിലയിൽ നിന്നും അകറ്റി നിർത്തുക.
- പ്രോബ് കെയർ: Handle probes carefully. Avoid bending or kinking the cables. Store them properly to prevent damage to the tips and connectors.
- കാലിബ്രേഷൻ: Periodic calibration by qualified personnel is recommended to maintain measurement accuracy, especially after significant temperature changes or prolonged use.
7. പ്രശ്നപരിഹാരം
This section addresses common issues you might encounter with your SDS1104 oscilloscope.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| പവർ ഓണാക്കിയതിന് ശേഷം പ്രദർശനമില്ല. | Power cord not connected, power switch off, power supply issue. | Check power cord connection, ensure power switch is on, try a different power outlet. |
| തരംഗരൂപം പ്രദർശിപ്പിച്ചിട്ടില്ല. | Probe not connected, signal too small/large, trigger not set correctly, channel off. | Connect probe, adjust vertical scale (Volts/Div), press AUTO, check trigger settings, ensure channel is enabled. |
| Unstable waveform. | Incorrect trigger level or mode, noisy signal. | Adjust trigger level, change trigger mode (e.g., Edge, Auto), check signal source for noise. |
| Incorrect measurements. | Probe compensation incorrect, wrong probe attenuation setting. | Perform probe compensation, ensure probe attenuation (e.g., 1X, 10X) matches oscilloscope setting. |
ഈ പരിഹാരങ്ങൾ പരീക്ഷിച്ചതിനു ശേഷവും പ്രശ്നം നിലനിൽക്കുകയാണെങ്കിൽ, ദയവായി OWON ഉപഭോക്തൃ പിന്തുണയുമായി ബന്ധപ്പെടുക.
8 സ്പെസിഫിക്കേഷനുകൾ
Detailed technical specifications for the OWON SDS1104 oscilloscope.
| പരാമീറ്റർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| മോഡൽ | SDS1104 |
| ബാൻഡ്വിഡ്ത്ത് | 100MHz |
| ചാനലുകൾ | 4 |
| Sample Rate (Real-time) | Single CH: 1 GSa/s, Dual CH: 500 MSa/s, Four CH: 250 MSa/s |
| വേവ്ഫോം ക്യാപ്ചർ നിരക്ക് | 45,000 wfms/s |
| പ്രദർശിപ്പിക്കുക | 8" color LCD, TFT display, 800×600 pixels |
| Max Record Length | 40M (one channel), 20M (two channels), 10M (four channels) |
| ഇൻപുട്ട് കപ്ലിംഗ് | ഡിസി, എസി, ഗ്രൗണ്ട് |
| ഇൻപുട്ട് ഇംപെഡൻസ് | 1MΩ±2%, in parallel with 15pF±5pF |
| പരമാവധി ഇൻപുട്ട് വോളിയംtage | 400 V (DC + AC Peak) |
| ലംബ സംവേദനക്ഷമത | 1 mV/div - 10 V/div |
| ട്രിഗർ തരം | Edge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, RS232, CAN (optional) |
| Decoding Type (optional) | RS232, I2C, SPI, CAN |
| യാന്ത്രിക അളവ് | കാലയളവ്, ആവൃത്തി, ശരാശരി, പികെ-പികെ, ആർഎംഎസ്, പരമാവധി, കുറഞ്ഞത്, മുകളിൽ, ബേസ്, Amplitude, Overshoot, Preshoot, Rise Time, Fall Time, +Pulse Width, -Pulse Width, +Duty Cycle, -Duty Cycle, Delay A→B↑, Delay A→B↓, Phase A→B↑, Phase A→B↓, +Pulse Count, -Pulse Count, Rise Edge Count, Fall Edge Count, Area, Cycle Area |
| വേവ്ഫോം മാത്ത് | +, -, ×, /, FFT, Invert |
| വേവ്ഫോം സംഭരണം | 16 waveforms |
| ആശയവിനിമയ ഇൻ്റർഫേസ് | USB host, USB device |
| വൈദ്യുതി വിതരണം | 100V - 240V AC, 50/60Hz, CAT II |
| വൈദ്യുതി ഉപഭോഗം | <15W |
| അളവ് (W×H×D) | 301 × 152 × 70 മി.മീ |
| ഉപകരണ ഭാരം | ഏകദേശം 1.1 കിലോ |
9. വാറൻ്റിയും പിന്തുണയും
OWON products are manufactured under strict quality control standards. For warranty information, please refer to the warranty card included with your product or visit the official OWON webസൈറ്റ്.
For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact OWON customer service through their official channels. Ensure you have your product model (SDS1104) and serial number ready when contacting support.
OWON ഒഫീഷ്യൽ Webസൈറ്റ്: www.owon.com.hk