NJOY Echo Pro 2000

NJOY Echo Pro 2000 UPS Server User Manual

Model: Echo Pro 2000 | Brand: NJOY

1. ആമുഖം

The NJOY Echo Pro 2000 is an advanced Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical equipment such as servers, workstations, and networking devices. Featuring double conversion online technology, it delivers a pure sine wave output, ensuring the highest degree of compatibility and protection for sensitive electronics. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Echo Pro 2000 UPS.

NJOY Echo Pro 2000 UPS front view

ചിത്രം 1.1: മുൻഭാഗം view of the NJOY Echo Pro 2000 UPS. This image shows the main unit with its front panel display and control buttons.

2 സുരക്ഷാ വിവരങ്ങൾ

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

  • ഇലക്ട്രിക്കൽ സുരക്ഷ: The UPS contains hazardous voltages. Do not attempt to disassemble the unit. Servicing should only be performed by qualified personnel.
  • ബാറ്ററി സുരക്ഷ: Batteries can present a risk of electrical shock and high short-circuit current. Observe proper polarity when connecting batteries. Do not dispose of batteries in a fire.
  • പരിസ്ഥിതി: Install the UPS in a well-ventilated area, free from excessive dust, humidity, and corrosive substances. Avoid direct sunlight and heat sources.
  • ഗ്രൗണ്ടിംഗ്: Ensure the UPS is properly grounded to prevent electrical shock.
  • എമർജൻസി പവർ ഓഫ് (EPO): Familiarize yourself with the EPO function for immediate shutdown in emergencies.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

3.1 പ്രധാന സവിശേഷതകൾ

  • Double Conversion Online Technology: Provides continuous, clean power by converting incoming AC to DC and then back to AC, isolating connected equipment from utility power fluctuations.
  • പ്യുവർ സൈൻ വേവ് ഔട്ട്പുട്ട്: Ensures compatibility with all types of electronic loads, preventing distortion and electrical noise.
  • കുറഞ്ഞ ശബ്ദ നില: Operates at less than 40 dB, suitable for office environments.
  • സോഫ്റ്റ്‌വെയർ മാനേജ്മെന്റ്: Includes specialized software for remote monitoring, scheduled power on/off, battery tests, and complete UPS configuration.
  • ആശയവിനിമയ തുറമുഖങ്ങൾ: Equipped with RS232, HID USB, and EPO ports. An optional SNMP card slot is available for advanced network monitoring.
  • ആന്തരിക ബാറ്ററികൾ: Features 4 x 12V7Ah sealed lead-acid batteries for reliable backup power.

3.2 പിൻ പാനൽ കണക്ഷനുകൾ

NJOY Echo Pro 2000 UPS rear panel with labeled ports

Figure 3.1: Rear panel of the NJOY Echo Pro 2000 UPS, showing various connection ports.

  1. RS232 ഇന്റർഫേസ്: For serial communication with a computer or network device.
  2. Schuko Outlets (x4): Output receptacles for connecting protected equipment.
  3. ഇൻപുട്ട് സർക്യൂട്ട് ബ്രേക്കർ: Overcurrent protection for the UPS input.
  4. ഫാൻ: Cooling fan for internal components.
  5. SNMP Slot: Expansion slot for an optional SNMP card (not included) for network management.
  6. EPO (Emergency Power Off): Connector for remote emergency shutdown.
  7. USB ഇൻ്റർഫേസ്: For USB communication with a computer.
  8. എസി ഇൻപുട്ട്: Power input connector for the UPS.

4. സജ്ജീകരണം

Follow these steps to properly set up your NJOY Echo Pro 2000 UPS:

  1. അൺപാക്ക് ചെയ്യുന്നു: Carefully unpack the UPS and inspect it for any shipping damage. Report any damage to your dealer.
  2. പ്ലേസ്മെൻ്റ്: Place the UPS in a clean, dry, and well-ventilated indoor environment. Ensure adequate clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.
  3. പ്രാരംഭ ചാർജിംഗ്: Connect the UPS to a grounded AC power outlet using the provided power cord. Allow the UPS to charge for at least 8 hours before connecting any equipment to ensure optimal battery performance. The LCD display will indicate charging status.
  4. ബന്ധിപ്പിക്കുന്ന ഉപകരണങ്ങൾ: Once the UPS is fully charged, connect your critical equipment (servers, computers, monitors, etc.) to the Schuko output receptacles on the rear panel. Do not connect surge suppressors or power strips to the UPS output.
  5. ആശയവിനിമയ സജ്ജീകരണം: For monitoring and management, connect the UPS to your computer using the provided USB or RS232 cable. Install the specialized management software (refer to Section 5.2).
  6. EPO Connection (Optional): If using the Emergency Power Off function, connect the EPO cable to the designated port.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1 പവർ ഓൺ/ഓഫ്

  • പവർ ഓണാക്കാൻ: Press and hold the 'ON' button on the front panel for approximately 2 seconds until the UPS powers on and the LCD display illuminates.
  • പവർ ഓഫ് ചെയ്യാൻ: Press and hold the 'OFF' button for approximately 2 seconds. The UPS will shut down, and the display will turn off.

5.2 എൽസിഡി ഡിസ്പ്ലേയും നിയന്ത്രണ ബട്ടണുകളും

The front panel LCD provides real-time status information. Use the 'ENTER' and 'ESC' buttons to navigate through the display menus and view various parameters such as input/output voltage, battery level, load level, and operating mode.

5.3 സോഫ്റ്റ്‌വെയർ മാനേജ്‌മെന്റ്

The included software allows for comprehensive monitoring and control of the UPS. Install the software on a connected computer to:

  • Monitor real-time UPS status and parameters.
  • Schedule automatic power on/off and battery tests.
  • Configure UPS settings and alarm thresholds.
  • Receive notifications for power events.
  • Perform safe shutdown of connected computer systems during extended power outages.
Screenshot of the UPS management software interface

ചിത്രം 5.1: ഉദാample of the UPS management software interface, showing status and configuration options.

6. പരിപാലനം

പതിവ് അറ്റകുറ്റപ്പണികൾ നിങ്ങളുടെ യുപിഎസിന്റെ ദീർഘായുസ്സും മികച്ച പ്രകടനവും ഉറപ്പാക്കുന്നു.

  • ബാറ്ററി കെയർ: The UPS contains sealed lead-acid batteries. These batteries typically last 3-5 years under normal operating conditions. Replace batteries when their runtime significantly decreases. Only use replacement batteries of the same type and rating (4 x 12V7Ah). Battery replacement should be performed by qualified service personnel.
  • വൃത്തിയാക്കൽ: Keep the UPS clean and free of dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear of obstructions.
  • പരിസ്ഥിതി വ്യവസ്ഥകൾ: Maintain the UPS within the recommended operating temperature and humidity ranges to prolong its lifespan.
  • സ്വയം പരിശോധന: Periodically perform a battery self-test using the management software or front panel controls to assess battery health.

7. പ്രശ്‌നപരിഹാരം

This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact technical support.

പ്രശ്നം സാധ്യമായ കാരണം പരിഹാരം
യുപിഎസ് ഓണാക്കുന്നില്ല. No AC input; Low battery; UPS fault Check AC power cord connection; Allow UPS to charge; Contact support if fault persists.
UPS beeps continuously Overload; Low battery; UPS fault Reduce connected load; Allow UPS to charge; Check LCD for error codes.
കുറഞ്ഞ ബാക്കപ്പ് സമയം Overload; Batteries need replacement Reduce connected load; Perform battery test and replace if necessary.
Software not communicating with UPS Incorrect cable; Driver issue; Software settings Ensure correct USB/RS232 cable is used; Reinstall drivers; Check software communication settings.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർ സ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്എൻജോയ്
മോഡൽ നമ്പർUPOL-OL200EP-CG01B_SIL
ഉൽപ്പന്ന തരംടവർ യുപിഎസ്
സാങ്കേതികവിദ്യOnline (VFI) Double Conversion
പവർ കപ്പാസിറ്റി2000 VA / 1600 W
ഔട്ട്പുട്ട് പവർ ഫാക്ടർ0.8
ഇൻപുട്ട് നാമമാത്ര വോളിയംtage230 V എസി
ഇൻപുട്ട് വോളിയംtagഇ റേഞ്ച്80 - 300 V AC
ഇൻപുട്ട് ഫ്രീക്വൻസി50 Hz / 60 Hz (auto-sensing)
ഔട്ട്പുട്ട് നോമിനൽ വോളിയംtage208/220/230/240 V AC
ഔട്ട്പുട്ട് വേവ്ഫോംശുദ്ധമായ സൈൻ വേവ്
ഔട്ട്ലെറ്റുകൾ4 x ഷുകോ
ബാറ്ററികൾ4 x 12V7Ah Sealed Lead-Acid (internal)
കാര്യക്ഷമത96% വരെ
പ്രദർശിപ്പിക്കുകഎൽസിഡി
ആശയവിനിമയ തുറമുഖങ്ങൾRS232, HID USB, EPO, SNMP Slot (optional card)
ശബ്ദ നില<40 ഡിബി
അനുയോജ്യമായ ഉപകരണങ്ങൾGaming Computers, DVRs, Video Surveillance Systems, WiFi/ADSL/Fiber Modems, Monitors, Printers, TVs, NAS, Servers
UPS runtime chart showing power vs. duration

Figure 8.1: Runtime autonomy chart for the NJOY Echo Pro 2000 UPS. This chart illustrates the approximate backup duration at different load levels. For example, at 1600W (100% load), the runtime is approximately 1 minute, while at 400W (25% load), it is approximately 17 minutes.

9. വാറൻ്റി വിവരങ്ങൾ

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official NJOY webസൈറ്റ്. വാറന്റി ക്ലെയിമുകൾക്കായി നിങ്ങളുടെ വാങ്ങലിന്റെ തെളിവ് സൂക്ഷിക്കുക.

10. പിന്തുണ

If you require technical assistance or have questions regarding your NJOY Echo Pro 2000 UPS, please contact NJOY customer support through their official webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ ഉൽപ്പന്ന ഡോക്യുമെന്റേഷനിൽ നൽകിയിരിക്കുന്ന ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.