OWON HDS2202S
OWON HDS2202S Digital Handheld Oscilloscope
3-in-1 Oscilloscope, Multimeter, and Waveform Generator
Model: HDS2202S | Brand: OWON
ആമുഖം
The OWON HDS2202S is a versatile 3-in-1 digital handheld device integrating an oscilloscope, a 20,000-count multimeter, and a 1-channel waveform generator. Designed for portability and convenience, it is ideal for outdoor maintenance, rapid on-site measurements, automobile maintenance, and power detection. Its compact size and robust features make it an essential tool for professionals and enthusiasts alike.

Figure 1: OWON HDS2202S device and standard accessories.
പ്രധാന സവിശേഷതകൾ
- 3-ഇൻ-1 പ്രവർത്തനം: Combines a digital oscilloscope, a 20,000-count true RMS multimeter, and a 1-channel waveform generator.
- High Performance Oscilloscope: 200MHz bandwidth, 1GSa/s sample rate, 8K record length, 10,000 wfrms/s waveform refresh rate, 8 bits vertical resolution, 10mV/div - 10V/div vertical sensitivity.
- Advanced Multimeter: 20,000 count resolution, auto-ranging, supports measuring voltage (AC 750V/DC 1000V max input), current (DC 10A/AC 10A max input), resistance, diode, capacitance, and continuity.
- Versatile Waveform Generator: 25MHz signal generator, 125MSa/s sampling rate, 20 mVpp - 5 Vpp amplitude range (high impedance), 8K waveform length, 14-bit vertical resolution, 50Ω output impedance. Outputs Sine (0.1Hz - 25MHz), Square/Pulse/Arbitrary (0.1Hz - 5MHz), and Ramp (0.1Hz - 1MHz) waveforms.
- ഡിസ്പ്ലേ മായ്ക്കുക: 3.5-inch color LCD with adjustable brightness and backlight time for optimal readability in various lighting conditions.
- കണക്റ്റിവിറ്റി: USB Type-C interface for communication with a computer and support for external power banks. Standard SCPI communication function for secondary development.
- സുരക്ഷ: Built-in fuse for automatic device protection.

ചിത്രം 2: ഓവർview of the HDS2202S's integrated functions.
ബോക്സിൽ എന്താണുള്ളത്
The standard package for your OWON HDS2202S includes the following items:
- 1 x OWON HDS2202S Main Unit
- 2 x Oscilloscope Probes (pairs of probe and probe adjust)
- 2 x BNC Leads (including BNC to Alligator Clip and BNC Q9 cable)
- 1 x Multimeter Lead (pair)
- 1 x Multimeter Test Lead (additional set)
- 1 x യുഎസ്ബി ടൈപ്പ്-സി കേബിൾ
- 1 x പവർ അഡാപ്റ്റർ
- 1 x Soft Carrying Bag
- 1 x ഉൽപ്പന്ന മാനുവൽ (ഈ പ്രമാണം)

Figure 3: All included accessories for the HDS2202S.
സജ്ജമാക്കുക
1 ഉപകരണം ചാർജ് ചെയ്യുന്നു
The HDS2202S comes with built-in lithium-ion batteries. Before first use, fully charge the device using the provided USB Type-C cable and power adapter. A full charge typically provides approximately 6 hours of continuous operation.
- Connect the USB Type-C cable to the port on the side of the device.
- USB കേബിളിന്റെ മറ്റേ അറ്റം പവർ അഡാപ്റ്ററുമായി ബന്ധിപ്പിച്ച് ഒരു വാൾ ഔട്ട്ലെറ്റിൽ പ്ലഗ് ചെയ്യുക.
- ഉപകരണത്തിലെ ചാർജിംഗ് ഇൻഡിക്കേറ്റർ ചാർജിംഗ് സ്റ്റാറ്റസ് കാണിക്കും.

Figure 4: HDS2202S internal battery and fuse for protection.
2. Initial Power On and Display Settings
Press and hold the power button to turn on the device. Upon first power-on, you may wish to adjust display settings for optimal viewing.
- എന്നതിലേക്ക് നാവിഗേറ്റ് ചെയ്യുക സിസ്റ്റം മെനു.
- ക്രമീകരിക്കുക തെളിച്ചം (System → F1 → F1) and ബാക്ക്ലൈറ്റ് സമയം (System → F1 → F2) as needed.
- The device features a 3.5-inch color LCD.

Figure 5: HDS2202S LCD display features.
3. Connecting Probes and Leads
Connect the appropriate probes or leads based on the function you intend to use (Oscilloscope, Multimeter, or Waveform Generator). Ensure secure connections for accurate measurements.

Figure 6: HDS2202S port locations and dimensions.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
സ്വിച്ചിംഗ് മോഡുകൾ
The HDS2202S allows seamless switching between Oscilloscope, Multimeter, and Waveform Generator modes. Use the മോഡ് ലഭ്യമായ ഫംഗ്ഷനുകളിലൂടെ സൈക്കിൾ ചെയ്യാൻ ബട്ടൺ.
1. Oscilloscope Function
The oscilloscope mode allows for waveform observation and analysis. It features 2 channels with 200MHz bandwidth and 1GSa/s sample നിരക്ക്.
- Connect oscilloscope probes to CH1 and/or CH2 input connectors.
- അമർത്തുക മോഡ് until the oscilloscope interface is displayed.
- Use the navigation buttons to adjust vertical sensitivity (V/div), horizontal time base (s/div), and trigger settings.
- ദി ഓട്ടോ button can automatically set optimal display parameters for the input signal.
- Utilize cursor measurement and multiple auto measurement functions for detailed analysis.


Figure 7: Oscilloscope mode displaying waveforms.
2. Multimeter Function
The multimeter mode provides precise measurements of various electrical parameters with 20,000 counts resolution.
- Connect the multimeter leads to the appropriate input jacks (VΩ+C, mA, A, COM).
- അമർത്തുക മോഡ് until the multimeter interface is displayed.
- Use the function buttons (F1-F4) or navigation to select the desired measurement type (Voltage, Current, Resistance, Diode, Capacitance, Continuity).
- The device supports auto-ranging for ease of use.

Figure 8: Multimeter mode displaying voltagഇ അളവ്.
3. Waveform Generator Function
The built-in waveform generator can output various standard and arbitrary waveforms for testing and calibration purposes.
- Connect a BNC lead to the GEN OUT connector.
- അമർത്തുക മോഡ് until the waveform generator interface is displayed.
- Adjust parameters such as frequency, amplitude (Vpp), offset, and waveform type (Sine, Square, Ramp, Pulse, Arbitrary) using the navigation and function buttons.

Figure 9: Waveform Generator mode settings.
4. പിസി കമ്മ്യൂണിക്കേഷൻ
The HDS2202S can connect to a computer via its USB Type-C interface for data transfer and remote control using compatible software. It supports standard SCPI commands for advanced users and secondary development.
- Connect the device to your computer using the provided USB Type-C cable.
- Install the necessary drivers and software (available from the manufacturer's webസൈറ്റ്).
- Follow the software instructions for data logging, waveform analysis, and remote control.

Figure 10: HDS2202S connected to PC for software interaction.
Official Product Video Demonstration
Video 1: Official product video demonstrating the key features and portability of the OWON HDS series, highlighting its use in various applications like outdoor maintenance, on-site measurement, and power detection. It also showcases the multimeter and waveform generator functions.
മെയിൻ്റനൻസ്
- വൃത്തിയാക്കൽ: ഉപകരണം വൃത്തിയാക്കാൻ മൃദുവായതും ഉണങ്ങിയതുമായ തുണി ഉപയോഗിക്കുക. അബ്രസീവ് ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
- സംഭരണം: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Use the provided soft bag for protection during storage and transport.
- ബാറ്ററി കെയർ: For long-term storage, ensure the battery is charged to approximately 50%. Recharge every few months to prevent deep discharge.
- പ്രോബ് കെയർ: Handle probes and leads carefully. Avoid sharp bends or excessive pulling that could damage the cables. Regularly inspect for wear and tear.
- ഫ്യൂസ് മാറ്റിസ്ഥാപിക്കൽ: The device has a built-in fuse for protection. If the device stops functioning due to an overload, the fuse may need replacement. Refer to a qualified technician for fuse replacement.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ഉപകരണം പവർ ഓണാക്കുന്നില്ല. | Low battery; Power button not pressed long enough; Internal fault. | Charge the device fully. Press and hold the power button for a few seconds. If problem persists, contact support. |
| ഓസിലോസ്കോപ്പ് മോഡിൽ തരംഗരൂപം പ്രദർശിപ്പിച്ചിട്ടില്ല. | Probes not connected correctly; Input signal too small or too large; Incorrect time base or vertical scale settings; Trigger not set correctly. | Ensure probes are securely connected. Adjust V/div and s/div settings. Use the ഓട്ടോ button. Check trigger level and mode. |
| Multimeter readings are inaccurate or "OL" (Overload). | Incorrect measurement range; Leads not connected properly; Faulty leads. | Ensure correct measurement type is selected. Check lead connections. Try different leads if available. The device supports auto-ranging, but manual range selection might be needed for specific cases. |
| Waveform generator output is incorrect or absent. | Incorrect settings (frequency, amplitude, offset); Output not enabled; Faulty BNC cable. | Verify all waveform generator settings. Ensure "Output ON" is selected. Check the BNC cable for damage or poor connection. |
| പിസിയിലേക്ക് കണക്റ്റ് ചെയ്യാൻ കഴിയുന്നില്ല. | USB cable issue; Driver not installed; Software not running or configured correctly. | Use the provided USB Type-C cable. Install the latest drivers from the manufacturer. Ensure the PC software is correctly installed and configured. |
സ്പെസിഫിക്കേഷനുകൾ
| പരാമീറ്റർ | വിശദാംശങ്ങൾ |
|---|---|
| മോഡൽ നമ്പർ | എച്ച്ഡിഎസ്2202എസ് |
| ഉൽപ്പന്ന അളവുകൾ | 7.8 x 1.5 x 3.78 ഇഞ്ച് (198 x 38 x 96 മിമി) |
| ഭാരം | 1.31 Pounds (Approx. 0.6 kg without battery) |
| ഓസിലോസ്കോപ്പ് ബാൻഡ്വിഡ്ത്ത് | 200MHz |
| ഓസിലോസ്കോപ്പ് എസ്ample നിരക്ക് | 1GSa/s |
| ഓസിലോസ്കോപ്പ് ചാനലുകൾ | 2 ചാനലുകൾ |
| റെക്കോർഡ് ദൈർഘ്യം | 8K |
| വേവ്ഫോം പുതുക്കൽ നിരക്ക് | 10,000 wfrms/s |
| ലംബ മിഴിവ് | 8 ബിറ്റുകൾ |
| ലംബ സംവേദനക്ഷമത | 10mV/div - 10V/div |
| മൾട്ടിമീറ്റർ എണ്ണങ്ങൾ | 20,000 എണ്ണം |
| പരമാവധി ഇൻപുട്ട് വോളിയംtage (Multimeter) | AC 750V / DC 1000V |
| Max Input Current (Multimeter) | DC 10A / AC 10A |
| Waveform Generator Frequency | Sine (0.1Hz - 25MHz), Square/Pulse/Arbitrary (0.1Hz - 5MHz), Ramp (0.1Hz - 1MHz) |
| വേവ്ഫോം ജനറേറ്റർ Ampഅക്ഷാംശം | 20 mVpp - 5 Vpp (high impedance) |
| Waveform Generator Vertical Resolution | 14 ബിറ്റുകൾ |
| പ്രദർശിപ്പിക്കുക | 3.5 ഇഞ്ച് കളർ എൽസിഡി |
| ബാറ്ററി തരം | 2 ലിഥിയം അയോൺ ബാറ്ററികൾ (ഉൾപ്പെട്ടിരിക്കുന്നു) |
വാറൻ്റിയും പിന്തുണയും
OWON products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official OWON webനിങ്ങളുടെ സൈറ്റിൽ ബന്ധപ്പെടുക അല്ലെങ്കിൽ നിങ്ങളുടെ പ്രാദേശിക വിതരണക്കാരനെ ബന്ധപ്പെടുക. വാറന്റി ക്ലെയിമുകൾക്കുള്ള വാങ്ങലിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
For the latest software updates and additional resources, visit the official OWON support page.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.