ആമുഖം
Thank you for choosing the EMKE 60x30cm Single Layer Flat Hot Water Radiator. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new radiator. Please read these instructions carefully before installation and retain them for future reference.
സുരക്ഷാ വിവരങ്ങൾ
- Ensure all installation work is carried out by a qualified professional in accordance with local building and plumbing regulations.
- Do not cover the radiator with clothing or other materials, as this can impede heat dissipation and pose a fire hazard.
- Keep children and pets away from the hot surface of the radiator to prevent burns.
- Before any maintenance or cleaning, ensure the heating system is turned off and the radiator has cooled down.
- Do not modify the radiator or its components. Use only original EMKE spare parts if replacements are needed.
പാക്കേജ് ഉള്ളടക്കം
ഇൻസ്റ്റാളേഷൻ ആരംഭിക്കുന്നതിന് മുമ്പ് എല്ലാ ഘടകങ്ങളും നിലവിലുണ്ടെന്നും കേടുപാടുകൾ സംഭവിച്ചിട്ടില്ലെന്നും ഉറപ്പാക്കുക.
- EMKE Radiator Panel (60x30cm, single layer)
- Mounting Kit (brackets, screws, wall plugs)
- ഇൻസ്റ്റലേഷൻ നിർദ്ദേശങ്ങൾ
NOTE: The valve is not included and must be purchased separately.
സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| നിർമ്മാതാവ് | ഇ.എം.കെ |
| മോഡൽ | 60x30cm Single Layer |
| നിറം | വെള്ള |
| മെറ്റീരിയൽ | High-quality SPCC Steel (compliant with BS EN 442) |
| അളവുകൾ (ഉയരം x വീതി) | 60 x 30 സെ.മീ |
| ഹീറ്റ് ഔട്ട്പുട്ട് | 233 വാട്ട്സ് |
| ട്യൂബുകളുടെ എണ്ണം | 4 |
| ആപ്ലിക്കേഷൻ ഏരിയ | 3.1㎡ |
| കണക്ഷൻ തരം | Central Connection |
| കണക്ഷൻ ത്രെഡ് | ജി1/2" |
| കണക്ഷൻ വലുപ്പം | 50 മി.മീ |
| Distance from Interface to Wall | 55 മി.മീ |
The radiator is designed for vertical wall mounting.

Image: Radiator dimensions and specification table for various models.
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
This section outlines the general steps for installing your EMKE radiator. Always refer to the detailed installation instructions provided in the package and consult a qualified professional.
1. പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധനകൾ
- Ensure the wall can support the weight of the radiator when filled with water.
- Confirm you have the correct valves (not included) for your central heating system.
- എല്ലാ പാക്കേജ് ഉള്ളടക്കങ്ങളും ഉണ്ടെന്നും കേടുപാടുകൾ സംഭവിച്ചിട്ടില്ലെന്നും പരിശോധിക്കുക.
2. Mounting the Radiator
- Mark the desired position for the radiator on the wall, ensuring it is level and allows for proper pipe connections.
- Drill holes for the mounting brackets according to the provided template.
- Secure the mounting brackets firmly to the wall using the supplied screws and wall plugs.
- Carefully hang the radiator onto the installed brackets.

Image: Vertical and horizontal radiator mounting exampലെസ്.
3. Connecting to the Heating System
The radiator features a central connection with a G1/2" thread and a 50mm connection size. The distance from the interface to the wall is 55mm.
- Connect the flow and return pipes from your central heating system to the radiator's central connection points using appropriate valves (not included).
- Ensure all connections are watertight and properly sealed.
- For single layer radiators, the mounting direction is fixed. Double layer radiators can be mounted in both directions.

Image: Diverse connection methods for the radiator.

Image: Flexible installation modes for the radiator.
4. Filling and Bleeding the System
- Once connected, slowly fill the heating system with water.
- Bleed the radiator using the bleed valve to release any trapped air until water flows steadily.
- ചോർച്ചയ്ക്കായി എല്ലാ കണക്ഷനുകളും പരിശോധിക്കുക.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The EMKE radiator operates as part of your central hot water heating system. Its high thermal conductivity ensures efficient heating.
- ഓൺ/ഓഫ് ചെയ്യുന്നു: Control the radiator's heat output via your central heating system's thermostat or the individual radiator valve (if installed).
- താപനില നിയന്ത്രണം: Adjust the desired room temperature using your central heating thermostat. If equipped with a thermostatic radiator valve (TRV), you can regulate the heat output of this specific radiator independently.
- കാര്യക്ഷമമായ ചൂടാക്കൽ: The radiator's design and SPCC steel material allow for rapid heat transfer, quickly warming the surrounding air.

Image: Radiator providing warmth in a bathroom setting.
മെയിൻ്റനൻസ്
പതിവ് അറ്റകുറ്റപ്പണികൾ നിങ്ങളുടെ റേഡിയേറ്ററിന്റെ ഒപ്റ്റിമൽ പ്രകടനവും ദീർഘായുസ്സും ഉറപ്പാക്കുന്നു.
- വൃത്തിയാക്കൽ: Clean the radiator regularly with a soft, damp തുണി. ഫിനിഷിന് കേടുവരുത്തുന്ന ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഒഴിവാക്കുക.
- രക്തസ്രാവം: Periodically bleed your radiators to remove any trapped air, which can reduce heating efficiency. This should be done when the heating system is cold.
- പരിശോധനകൾ: Annually inspect the radiator and connections for any signs of corrosion, leaks, or damage. Address any issues promptly.
- സിസ്റ്റം മർദ്ദം: Ensure your central heating system maintains the correct pressure as recommended by your boiler manufacturer.

Image: High-quality multi-layer materials used in the radiator construction.

Image: Seamless welding technique for enhanced durability.
ട്രബിൾഷൂട്ടിംഗ്
If you encounter issues with your radiator, refer to the following common problems and solutions.
- Radiator Not Heating Up:
- Check if the central heating system is on and functioning correctly.
- Bleed the radiator to remove trapped air.
- Ensure the radiator valve is fully open.
- Check the system pressure on your boiler.
- Radiator Cold at the Top, Hot at the Bottom: This usually indicates trapped air. Bleed the radiator.
- ചോർച്ച കണക്ഷനുകൾ: Turn off the heating system, allow the radiator to cool, and carefully tighten any leaking connections. If the leak persists, contact a qualified plumber.
- Unusual Noises (e.g., banging, gurgling): This could be due to air in the system (bleed the radiator) or incorrect water pressure. Consult your boiler manual or a professional.
For persistent issues or problems not listed here, please contact EMKE customer support or a qualified heating engineer.
വാറൻ്റിയും പിന്തുണയും
EMKE products are manufactured to high standards and come with a standard warranty. Please refer to the warranty card included in your package for specific terms and conditions.
For technical assistance, spare parts, or warranty claims, please contact EMKE customer support through the retailer where you purchased the product or visit the official EMKE website. When contacting support, please have your product model (60x30cm Single Layer) and ASIN (B0CJLR5S9C) ready.

Image: EMKE Customer Support.