ഉൽപ്പന്നം കഴിഞ്ഞുview
The Biral HE-circulatiepomp PrimAX T2 25-5 180 RED G 1 1/2 230V with heat-insulating shell is a high-efficiency circulation pump designed for heating systems. The PrimAX T2 model is known for its above-average energy efficiency, making it a reliable and economical choice for various applications.
പ്രധാന സവിശേഷതകൾ
- Nominal width DN 25, maximum head H max. 5 m.
- Installation length 180 mm.
- Threaded connection G 1 1/2 inch.
- പരമാവധി പ്രവർത്തന മർദ്ദം 10 ബാർ.
- Medium temperature range: minimum +2 °C to maximum +110 °C.
- Ambient temperature range: 0 - 40 °C.
- Net weight 2 kg.
- High energy efficiency (EEI value).
ഉൽപ്പന്ന ദൃശ്യങ്ങൾ

Image: The Biral PrimAX T2 circulation pump, featuring its black heat-insulating shell and integrated control panel with display and adjustment buttons. The threaded connections are visible at the top and bottom.
സജ്ജീകരണ ഗൈഡ്
Proper installation is crucial for the optimal performance and longevity of your Biral PrimAX T2 circulation pump. It is highly recommended that installation be performed by a qualified professional to ensure compliance with local regulations and safety standards.
- തയ്യാറാക്കൽ: Ensure the heating system is depressurized and cooled down. Isolate the section where the pump will be installed.
- മൗണ്ടിംഗ് സ്ഥാനം: Install the pump in a horizontal position with the motor shaft horizontal to prevent air pockets and ensure proper lubrication.
- കണക്ഷനുകൾ: Connect the pump to the heating system pipes using the G 1 1/2 inch threaded connections. Ensure all connections are sealed properly to prevent leaks.
- ഇലക്ട്രിക്കൽ കണക്ഷൻ: Connect the pump to a 230V power supply according to the wiring diagram provided in the full technical manual (not included here). Ensure the power supply is disconnected before making any electrical connections.
- ഇൻസുലേഷൻ: The pump comes with a heat-insulating shell. Ensure it is properly fitted to maximize energy efficiency and prevent heat loss.
- Filling and Venting: After installation, refill the heating system and carefully vent all air from the system, including the pump, to prevent dry running and noise.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The Biral PrimAX T2 pump is designed for user-friendly operation. Once properly installed and powered, the pump will begin circulating the heating medium. The integrated control panel allows for adjustment of operating modes and settings.
- പവർ ഓൺ: After electrical connection, switch on the power supply to the pump. The display will illuminate, indicating the pump is active.
- മോഡ് തിരഞ്ഞെടുക്കൽ: Use the control buttons on the display to cycle through available operating modes (e.g., constant pressure, proportional pressure, fixed speed). Refer to the pump's display for current settings and indicators.
- Performance Adjustment: Depending on the selected mode, you can adjust the desired head or speed using the up/down buttons. The display will show the current performance parameters.
- നിരീക്ഷണം: The display provides real-time information on pump status, energy consumption, and flow rate (if applicable).
മെയിൻ്റനൻസ്
Regular maintenance ensures the efficient and reliable operation of your Biral PrimAX T2 circulation pump. Always disconnect the power supply before performing any maintenance tasks.
- വിഷ്വൽ പരിശോധന: Periodically check the pump and connections for any signs of leaks, corrosion, or damage.
- ശുചിത്വം: Keep the pump and its surroundings clean and free from dust and debris to ensure proper ventilation.
- System Water Quality: Ensure the heating system water quality is maintained according to manufacturer recommendations to prevent scale buildup and corrosion within the pump.
- പ്രൊഫഷണൽ പരിശോധന: It is advisable to have the heating system, including the pump, inspected by a qualified technician annually.
ട്രബിൾഷൂട്ടിംഗ്
If you encounter issues with your Biral PrimAX T2 circulation pump, refer to the following common troubleshooting steps. For complex problems, contact a qualified professional.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Pump not running / No display | No power supply; Blown fuse; Internal fault. | Check power connection and circuit breaker. Replace fuse if necessary. If problem persists, contact service. |
| Pump running, but no circulation | Air in system; Closed valves; Blockage in pipes or pump. | Vent the heating system and pump. Check if all necessary valves are open. Inspect for blockages (professional assistance may be required). |
| പമ്പിൽ നിന്ന് അസാധാരണമായ ശബ്ദം | Air in system; Cavitation; Incorrect mounting; Worn bearings. | Vent the system thoroughly. Ensure sufficient system pressure. Check mounting for vibrations. If noise persists, professional inspection is needed. |
| പമ്പ് ചോർച്ച | അയഞ്ഞ കണക്ഷനുകൾ; കേടായ സീലുകൾ. | Tighten connections. If seals are damaged, professional repair or replacement is required. |
സാങ്കേതിക സവിശേഷതകൾ
| ആട്രിബ്യൂട്ട് | മൂല്യം |
|---|---|
| നിർമ്മാതാവ് | ബിരാൾ |
| ഭാഗം നമ്പർ | 7000001831 |
| പാക്കേജ് അളവുകൾ | 19 x 18 x 13 സെ.മീ |
| ഇനം മോഡൽ നമ്പർ | 7000001831 |
| ബാറ്ററികൾ ആവശ്യമാണ് | ഇല്ല |
| ASIN | B0CPM9VFK7 |
| ആദ്യം ലഭ്യമായ തീയതി | ഡിസംബർ 6, 2023 |
| നാമമാത്ര വീതി | DN 25 |
| Max. Head (H max.) | 5 മീ |
| Installation Length | 180 മി.മീ |
| ത്രെഡ്ഡ് കണക്ഷൻ | ജി 1 1/2 ഇഞ്ച് |
| പരമാവധി. പ്രവർത്തന സമ്മർദ്ദം | 10 ബാർ |
| Medium Temperature Min. | +2 °C |
| Medium Temperature Max. | +110 °C |
| ആംബിയൻ്റ് താപനില | 0 - 40 ഡിഗ്രി സെൽഷ്യസ് |
| മൊത്തം ഭാരം | 2 കി.ഗ്രാം |
വാറൻ്റി വിവരങ്ങൾ
This product comes with a return policy allowing for refunds or replacements within 30 days from the date of purchase. For detailed warranty terms and conditions, please refer to the documentation provided with your product or contact the seller directly.
ഉപഭോക്തൃ പിന്തുണ
For technical assistance, troubleshooting beyond this guide, or warranty claims, please contact the seller or manufacturer. You can reach the seller, Selfio, Do it yourself. Aber do it richtig, through their Amazon seller page: Selfio Seller Page.