ZJchao ZJchaos2tgrzv4ce-12

ZJchao 12V Linear Actuator Instruction Manual

Model: ZJchaos2tgrzv4ce-12

1. ആമുഖം

This instruction manual provides essential information for the safe and efficient use of your ZJchao 12V Linear Actuator. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. ഉൽപ്പന്ന സവിശേഷതകൾ

  • ശക്തമായ സംരക്ഷണം: Designed with an internal limit switch and a 12V input voltage, boasting an IP60 grade for dependable operation across various conditions.
  • നീണ്ടുനിൽക്കുന്ന നിർമ്മാണം: Utilizes advanced powder metallurgy technology in its fuselage, ensuring sturdiness and extending the actuator's lifespan.
  • ഒതുക്കമുള്ളതും ഭാരം കുറഞ്ഞതും: Features a geared motor, making it lightweight and compact for easy integration into tight spaces.
  • ബഹുമുഖ പ്രയോഗങ്ങൾ: Suitable for a wide range of uses, including equipment, industrial automation, agricultural machinery, catering systems, and ventilation services.
  • കാര്യക്ഷമമായ പ്രവർത്തനം: Offers a 30mm stroke with noise elimination features and short circuit protection, optimizing performance for various applications.

3 സ്പെസിഫിക്കേഷനുകൾ

പരാമീറ്റർമൂല്യം
ഇൻപുട്ട് വോളിയംtage12V
സ്ട്രോക്ക് ദൈർഘ്യം30 മി.മീ
പ്രവർത്തന വേഗത8mm/s
നിർബന്ധിക്കുക70N
പ്രവർത്തന താപനില0℃ - 40℃
പരിധി സ്വിച്ചുകൾആന്തരികം
ജോലി നിരക്ക്10%
Inner Tube Materialഅലുമിനിയം ട്യൂബ്
സ്ക്രൂ തരംT Screw
സംരക്ഷണ ഗ്രേഡ്IP60
മോഡൽ നമ്പർZJchaos2tgrzv4ce-12
ASINB0DQ4MXRYR

4 സുരക്ഷാ വിവരങ്ങൾ

Always observe the following safety precautions to prevent injury or damage to the actuator:

  • Ensure the power supply matches the actuator's voltage (12V DC).
  • Do not exceed the rated load capacity (70N).
  • Avoid operating the actuator beyond its specified work rate (10%). Continuous operation can lead to overheating and damage.
  • പ്രവർത്തിക്കുമ്പോൾ കൈകളും വസ്ത്രങ്ങളും ചലിക്കുന്ന ഭാഗങ്ങളിൽ നിന്ന് അകറ്റി നിർത്തുക.
  • Do not modify the actuator or its internal components.
  • Ensure proper ventilation around the actuator during operation.
  • Disconnect power before performing any installation, maintenance, or troubleshooting.

5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Follow these steps for proper installation of your linear actuator:

  1. മൗണ്ടിംഗ്: Securely attach the actuator to a stable surface using appropriate fasteners through the mounting holes at both ends. Ensure the mounting points can withstand the actuator's maximum force.
  2. ഇലക്ട്രിക്കൽ കണക്ഷൻ: Connect the actuator to a 12V DC power source. The actuator typically has two wires (red and black). Connect the red wire to the positive (+) terminal and the black wire to the negative (-) terminal for extension. Reversing the polarity will cause the actuator to retract.
ZJchao 12V Linear Actuator, front view

ചിത്രം 1: മുൻഭാഗം view of the ZJchao 12V Linear Actuator, showing its compact design and mounting points.

ZJchao 12V Linear Actuator, wiring detail

Figure 2: Close-up of the wiring connections on the ZJchao 12V Linear Actuator, illustrating the red and black power leads.

  1. പരിശോധന: After installation, apply power to test the extension and retraction. Observe for smooth operation and ensure the internal limit switches stop the actuator at its full stroke.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The ZJchao 12V Linear Actuator is designed for simple operation:

  • വിപുലീകരണം: Apply 12V DC power with correct polarity (red to +, black to -). The actuator rod will extend until it reaches its full 30mm stroke, at which point the internal limit switch will stop it.
  • പിൻവലിക്കൽ: Reverse the polarity of the 12V DC power supply (red to -, black to +). The actuator rod will retract until it reaches its fully retracted position, where the internal limit switch will stop it.
  • ഡ്യൂട്ടി സൈക്കിൾ: The actuator has a work rate of 10%. This means it should operate for a maximum of 1 minute, followed by a minimum of 9 minutes of rest. Exceeding this duty cycle can lead to overheating and premature failure.

7. പരിപാലനം

Regular maintenance ensures the longevity and reliable performance of your linear actuator:

  • വൃത്തിയാക്കൽ: Keep the actuator rod and housing clean and free from dust, dirt, and debris. Use a soft, dry cloth. Avoid using harsh chemicals or solvents.
  • പരിശോധന: Periodically inspect the actuator for any signs of wear, damage, or loose connections. Check mounting points for security.
  • ലൂബ്രിക്കേഷൻ: The internal components are pre-lubricated. Do not attempt to lubricate the internal mechanism unless specifically instructed by the manufacturer. Keep the exposed part of the actuator rod clean.
  • സംഭരണം: Store the actuator in a dry, clean environment within the specified operating temperature range when not in use.

8. പ്രശ്‌നപരിഹാരം

നിങ്ങളുടെ ലീനിയർ ആക്യുവേറ്ററിൽ പ്രശ്നങ്ങൾ നേരിടുകയാണെങ്കിൽ, ഇനിപ്പറയുന്ന പൊതുവായ പ്രശ്നങ്ങളും പരിഹാരങ്ങളും പരിശോധിക്കുക:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ആക്യുവേറ്റർ നീങ്ങുന്നില്ലNo power, incorrect wiring, overloaded, internal fault.Check power supply (12V DC). Verify wiring polarity. Reduce load. Contact support if internal fault is suspected.
Actuator moves intermittentlyLoose connections, insufficient power, duty cycle exceeded.Secure all electrical connections. Ensure stable 12V DC power. Allow actuator to cool down if duty cycle was exceeded.
പ്രവർത്തന സമയത്ത് അസാധാരണമായ ശബ്ദംExcessive load, foreign object, internal wear.Reduce load. Inspect for obstructions. If noise persists, contact support.
Actuator overheatsDuty cycle exceeded, excessive load, poor ventilation.Adhere to the 10% duty cycle. Reduce load. Ensure adequate airflow around the actuator.

9. വാറൻ്റിയും പിന്തുണയും

For warranty information or technical support, please refer to the product packaging or contact the retailer from whom you purchased the ZJchao 12V Linear Actuator. Please have your model number (ZJchaos2tgrzv4ce-12) and ASIN (B0DQ4MXRYR) ready when contacting support.

Ask a question about this manual