XINJE XC3-24T-E

XINJE XC3-24T-E PLC User Manual

Programmable Logic Controller Instruction Guide

1. ആമുഖവും അവസാനവുംview

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the XINJE XC3-24T-E Programmable Logic Controller (PLC). The XC3-24T-E is a robust industrial control device designed for various automation tasks, featuring a compact design and versatile connectivity options.

It is equipped with 14 digital inputs (DI) and 10 digital outputs (DO) with transistor output, suitable for AC220V or DC24V power supply systems. This PLC supports advanced programming capabilities and communication protocols, making it an ideal solution for modern industrial automation.

2. ഉൽപ്പന്ന സവിശേഷതകൾ

  • Integrated 14 Digital Inputs (DI) and 10 Digital Outputs (DO) with Transistor output.
  • Flexible power supply options: AC220V or DC24V.
  • Expandable with additional expansion modules and BD boards for increased I/O or specialized functions.
  • Built-in Real-Time Clock (RTC) for time-based operations.
  • Supports power-off retentive memory, ensuring data integrity during power interruptions.
  • Capable of basic logic control and complex data operations.
  • Advanced functionalities including high-speed counting, pulse output, and exterior interruption handling.
  • Supports C language function blocks for custom programming.
  • Features free switching for I/O points, enhancing configuration flexibility.
  • Supports free protocol communication and standard MODBUS communication for seamless integration with other devices.

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

3.1. വൈദ്യുതി വിതരണ കണക്ഷൻ

The XC3-24T-E PLC supports both AC220V and DC24V power inputs. Ensure the correct voltage is supplied to the designated power terminals. Refer to the wiring diagram on the device for specific terminal assignments. Always disconnect power before making any connections.

3.2. Input/Output Wiring

Connect your sensors and input devices to the 14 Digital Input (DI) terminals and your actuators and output devices to the 10 Digital Output (DO) transistor terminals. Pay close attention to polarity for DC circuits and ensure proper current ratings are observed for all connected devices.

3.3. ആശയവിനിമയ തുറമുഖങ്ങൾ

  • COM 1 (RS-232): Used for connecting to a host machine or Human Machine Interface (HMI) for programming, debugging, and data exchange.
  • COM 2 (RS-485/RS-232): Supports network communication or connection to intelligent instruments, inverters, and other industrial devices.
  • COM 3 (BD Extensional Communication Port RS-232/RS485): An additional port for extending communication capabilities.

3.4. ഫിസിക്കൽ ഇൻസ്റ്റലേഷൻ

The PLC can be installed using M3 screws for fixed mounting or by utilizing a DIN46277 (35mm width) guide rail. Ensure the installation location is stable, well-ventilated, and free from excessive vibration or electromagnetic interference.

3.5 ഗ്രൗണ്ടിംഗ്

Proper grounding is crucial for the safe and reliable operation of the PLC. Implement the third type of grounding. Never perform common grounding with a strong power system to prevent electrical hazards and interference.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

4.1. Programming the PLC

The XC3-24T-E supports programming in both instruction list and ladder diagram modes. User programs have a capacity of 8000 steps. Programming is typically performed via the COM 1 (RS-232) port using compatible PLC programming software on a host machine.

4.2. Program Operation Modes

The PLC operates in two primary program modes:

  • Circulation Scanning Mode: The PLC continuously scans and executes the user program from start to finish.
  • Timing Scanning Mode: Program execution is synchronized with specific time intervals.

The dispose speed for program execution is approximately 0.5 microseconds, ensuring rapid response times for control applications.

4.3. Data Retention

The PLC utilizes FlashROM for power failure holding, meaning user programs and critical data are retained even if power is lost, ensuring system integrity and minimizing downtime.

4.4. Timers and Counters

The PLC includes a comprehensive set of timers and counters for precise control:

  • Timers (T): 620 points available.
    • 100mS timer: Set time 0.1~3276.7 seconds
    • 10mS timer: Set time 0.01~327.67 seconds
    • 1mS timer: Set time 0.001~32.767 seconds
  • Counters (C): 635 points available.
    • 16 bits counter: Set value K0~32767
    • 32 bits counter: Set value K0~2147483647

Data Registers (D) provide 8512 characters for storing operational data.

5. പരിപാലനം

To ensure the longevity and reliable operation of your XINJE XC3-24T-E PLC, adhere to the following maintenance guidelines:

  • പരിസ്ഥിതി വ്യവസ്ഥകൾ: The PLC is designed to operate within an environment temperature range of 0°C to 6°C and an ambient humidity of 5% to 95% (non-condensing). Operating outside these ranges may affect performance and lifespan.
  • വൃത്തിയാക്കൽ: Regularly clean the exterior of the PLC with a soft, dry cloth. Avoid using abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris to prevent overheating.
  • കണക്ഷൻ പരിശോധനകൾ: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or system failures.
  • ഫേംവെയർ അപ്‌ഡേറ്റുകൾ: നിർമ്മാതാവ് പരിശോധിക്കുക website for any available firmware updates that may improve performance or address known issues. Follow update procedures carefully.
  • പവർ സപ്ലൈ സ്ഥിരത: Ensure a stable and clean power supply. Fluctuations or noise in the power supply can impact PLC operation.

6. പ്രശ്‌നപരിഹാരം

This section provides general guidance for common issues. For complex problems, consult the XINJE technical support or a qualified technician.

6.1. ഇൻഡിക്കേറ്റർ ലൈറ്റുകൾ

Observe the status indicator lights on the PLC front panel:

  • PWR (പവർ): Should be steadily lit when power is supplied correctly. If off, check power connections and source.
  • പ്രവർത്തിപ്പിക്കുക: Indicates the PLC is in run mode and executing the program. If off or blinking, the PLC may be in stop mode or encountering an issue.
  • ERR (പിശക്): If lit, an internal error or program error has occurred. Refer to the programming software for detailed error codes and diagnostics.

6.2. പൊതുവായ പ്രശ്നങ്ങൾ

  • PLC Not Powering On: വൈദ്യുതി വിതരണം വോളിയം പരിശോധിക്കുകtage matches the PLC's requirements (AC220V or DC24V). Check all power wiring for secure connections and continuity.
  • Inputs Not Responding: Check wiring to input devices. Ensure sensors are correctly powered and functioning. Verify input addresses in the PLC program match physical connections.
  • ഔട്ട്പുട്ടുകൾ സജീവമാകുന്നില്ല: Check wiring to output devices. Ensure actuators are correctly powered and functioning. Verify output addresses and logic in the PLC program. Check for overload or short circuits on output terminals.
  • ആശയവിനിമയ പ്രശ്നങ്ങൾ: Verify cable connections (RS-232/RS-485). Ensure communication parameters (baud rate, data bits, parity, stop bits) are correctly configured in both the PLC and the connected device (e.g., HMI, PC).
  • Program Errors: If the ERR light is on, connect to the PLC with programming software to identify the specific error. Common errors include syntax errors, logic faults, or memory issues.

7 സ്പെസിഫിക്കേഷനുകൾ

വിഭാഗംഇനംസ്പെസിഫിക്കേഷനുകൾ
ജനറൽഇൻസുലേഷൻ വോളിയംtageAbove DC 500V 2Mohm
Noise Resistance1000V 1uS pulse for 1 minute
പരിസ്ഥിതി താപനില0°C ~ 6°C
അന്തരീക്ഷ ഈർപ്പം5% ~ 95% (കണ്ടെൻസിംഗ് അല്ലാത്തത്)
ഇൻസ്റ്റലേഷൻM3 screw fixed or DIN46277 (35mm width) guide rail installation
ഗ്രൗണ്ടിംഗ്The third type grounding (Never perform common grounding with strong power system)
പ്രകടനംProgram Operation ModeCirculation scanning mode, timing scanning mode
പ്രോഗ്രാം മോഡ്Instructions and ladder chart
Dispose Speed0.5 യൂറോ
Power Failure HoldingFlashROM
User Program Capacity8000 പടികൾ
I/O പോയിന്റുകൾ14 input points, 10 output points
ഔട്ട്പുട്ട് ഫോർമാറ്റ്ട്രാൻസിസ്റ്റർ
വൈദ്യുതി വിതരണംAC220V/DC24V
Interior Coil Points (M)8512 പോയിൻ്റ്
Timer (T) Points620 പോയിൻ്റ്
Timer (T) Specification100mS timer: set time 0.1~3276.7 seconds
10mS timer: set time 0.01~327.67 seconds
1mS timer: set time 0.001~32.767 seconds
Counter (C) Points635 പോയിൻ്റ്
Counter (C) Specification16 bits counter: Set value K0~32767
32 bits counter: Set value K0~2147483647
Data Register (D)8512 പ്രതീകങ്ങൾ

8. ഉൽപ്പന്ന ചിത്രങ്ങൾ

XINJE XC3-24T-E PLC angled view

ചിത്രം 8.1: കോണാകൃതിയിലുള്ളത് view of the XINJE XC3-24T-E PLC, showing the input/output terminals and status indicators.

XINJE XC3-24T-E PLC top view

ചിത്രം 8.2: മുകളിൽ നിന്ന് താഴേക്ക് view of the XINJE XC3-24T-E PLC, highlighting the terminal blocks and model labeling.

XINJE XC3-24T-E PLC with retail packaging

Figure 8.3: The XINJE XC3-24T-E PLC alongside its retail packaging, showing the product box and included documentation.

9. വാറൻ്റിയും പിന്തുണയും

Specific warranty terms and detailed support contact information for the XINJE XC3-24T-E PLC are not available in the provided product data. For warranty claims, technical assistance, or further inquiries, please refer to the documentation included with your purchase or contact the vendor or manufacturer directly.

It is recommended to retain your proof of purchase for any warranty-related matters.

© 2024 XINJE. All rights reserved.

ഈ മാനുവൽ വിവരദായക ആവശ്യങ്ങൾക്ക് മാത്രമുള്ളതാണ്. മുൻകൂർ അറിയിപ്പ് കൂടാതെ സ്പെസിഫിക്കേഷനുകൾ മാറ്റത്തിന് വിധേയമാണ്.