ആമുഖം
This manual provides comprehensive instructions for the safe and effective operation, setup, maintenance, and troubleshooting of your Easy Core 125 Series Flux Core Welder. Please read this manual thoroughly before operating the welder to ensure proper use and to prevent injury or damage.
സുരക്ഷാ വിവരങ്ങൾ
Welding can be hazardous. Always follow safety precautions to prevent electric shock, fire, burns, and other serious injuries. Ensure proper ventilation, wear appropriate personal protective equipment (PPE) including welding helmet, gloves, and protective clothing. Keep a fire extinguisher nearby. Do not operate in damp conditions or near flammable materials.
- വൈദ്യുതാഘാതം: Can kill. Do not touch live electrical parts.
- പുകയും വാതകങ്ങളും: Can be hazardous to your health. Use adequate ventilation.
- ആർക്ക് കിരണങ്ങൾ: Can burn eyes and skin. Wear proper eye and body protection.
- തീയും സ്ഫോടനവും: Welding can cause fire or explosion. Keep flammables away.
ഉൽപ്പന്നം കഴിഞ്ഞുview
The Easy Core 125 Series is a portable flux-cored welder designed for various applications including farm, home, and shop use. It operates on 120V AC input and is capable of flux-cored welding (FCAW) processes.

This image displays the Easy Core 125 Series Flux Core Welder, a compact red and black unit with a top handle. Included accessories are visible: a welding gun with its cable, a ground clamp with its cable, a spool of flux-cored wire, and spare contact tips.
പ്രധാന ഘടകങ്ങൾ:
- നിയന്ത്രണ പാനൽ: സവിശേഷതകൾ വാല്യംtage and wire feed speed adjustments.
- വെൽഡിംഗ് തോക്ക്: Connects to the welder for wire feeding and arc initiation.
- ജോലി Clamp: ഇലക്ട്രിക്കൽ സർക്യൂട്ട് പൂർത്തിയാക്കാൻ വർക്ക്പീസുമായി ബന്ധിപ്പിക്കുന്നു.
- Wire Spool Compartment: Houses the flux-cored wire spool.
- പവർ കോർഡ്: For connecting to a 120V AC power source.
സജ്ജമാക്കുക
1. അൺപാക്ക് ചെയ്യലും പരിശോധനയും:
വെൽഡറും എല്ലാ അനുബന്ധ ഉപകരണങ്ങളും പാക്കേജിംഗിൽ നിന്ന് ശ്രദ്ധാപൂർവ്വം നീക്കം ചെയ്യുക. ഷിപ്പിംഗ് കേടുപാടുകൾ ഉണ്ടോ എന്ന് പരിശോധിക്കുക. എന്തെങ്കിലും കേടുപാടുകൾ സംഭവിച്ചാൽ ഉടൻ തന്നെ നിങ്ങളുടെ വിതരണക്കാരനെ അറിയിക്കുക.
2. പവർ കണക്ഷൻ:
Ensure the welder's power switch is in the OFF position. Connect the 5-15P plug to a grounded 120V AC, 20A dedicated circuit. Avoid using extension cords if possible; if necessary, use a heavy-duty, properly rated extension cord.
3. Wire Installation:
- Open the wire spool compartment.
- Mount the flux-cored wire spool onto the spindle, ensuring it rotates freely.
- Thread the wire through the drive roll system. Ensure the correct drive roll (0.030 in - 0.035 in for flux-core) is installed and tensioned properly.
- Feed the wire through the gun liner until it exits the contact tip.
4. Work Clamp കണക്ഷൻ:
ജോലി cl അറ്റാച്ചുചെയ്യുകamp securely to a clean, bare metal section of the workpiece. A good electrical connection is crucial for stable arc and quality welds.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
1. Basic Welding Principles (FCAW):
Flux-cored arc welding (FCAW) uses a continuously fed consumable electrode containing a flux. The flux provides shielding gas and slag to protect the weld puddle from atmospheric contamination. This welder operates in DC polarity.
2. Controls and Adjustments:
- വാല്യംtagഇ നിയന്ത്രണം: Adjusts the welding voltage (output range 30 to 125A DC). Higher voltage generally results in a wider, flatter bead.
- Wire Feed Speed Control: Adjusts the rate at which the wire is fed (50 to 500 in/min). This directly affects the amperage. Match wire feed speed to voltage for optimal arc stability.
3. വെൽഡിംഗ് ടെക്നിക്കുകൾ:
Position the welding gun at a slight angle (push or drag technique depending on application). Maintain a consistent arc length and travel speed. Practice on scrap material to achieve desired results. The welder is suitable for mild steel from 20 gauge to 5/16 inch thickness.
മെയിൻ്റനൻസ്
Regular maintenance ensures optimal performance and longevity of your welder.
- വൃത്തിയാക്കൽ: Periodically clean the welder's exterior and internal components (with compressed air) to remove dust and debris. Ensure power is disconnected before cleaning.
- Contact Tip Replacement: Replace worn or spattered contact tips as needed to ensure good electrical contact and consistent wire feeding.
- Drive Roll Maintenance: Keep the drive rolls clean and free of debris. Ensure proper tension for consistent wire feeding.
- Gun Liner: Inspect the gun liner for kinks or blockages that could impede wire feeding. Replace if necessary.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ആർക്ക് ഇല്ല | വൈദ്യുതിയില്ല, മോശം ജോലി.amp connection, faulty gun trigger. | വൈദ്യുതി വിതരണം പരിശോധിക്കുക, ജോലി സമയം ഉറപ്പാക്കുകamp is secure, inspect gun trigger and cable. |
| Inconsistent Wire Feed | Incorrect drive roll tension, clogged liner, wrong contact tip size. | Adjust drive roll tension, clean/replace liner, use correct contact tip. |
| മോശം വെൽഡ് ഗുണനിലവാരം | തെറ്റായ വോളിയംtage/wire speed settings, dirty workpiece, improper technique. | Adjust settings, clean workpiece, refine welding technique. |
സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| മോഡൽ | കെ 2696-1 |
| പരമ്പര | Easy-Core 125 |
| ഇൻപുട്ട് വോളിയംtage | 120V എസി |
| ഘട്ടം | സിംഗിൾ-ഫേസ് |
| ഇൻപുട്ട് ഫ്രീക്വൻസി | 60 Hz |
| വെൽഡിംഗ് പ്രക്രിയകൾ | Flux-Cored Welding (FCAW) |
| പോളാരിറ്റി | DC |
| റേറ്റുചെയ്ത ഔട്ട്പുട്ട് | 90A 19V ഡിസി |
| ഡ്യൂട്ടി സൈക്കിൾ | 20% |
| ഔട്ട്പുട്ട് ശ്രേണി | 30 മുതൽ 125A വരെ ഡിസി |
| Maximum Wire Diameter (Flux-Cored) | 0.035 ഇഞ്ച് |
| Maximum Wire Feed Speed | മിനിറ്റിൽ 500 |
| Minimum Wire Feed Speed | മിനിറ്റിൽ 50 |
| Material Thickness (Mild Steel) | 20 ga to 5/16 in |
| ഭാരം | 49 പൗണ്ട് |
| മൊത്തത്തിലുള്ള അളവുകൾ (W x D x H) | 10.15 ൽ x 17.9 ൽ x 13.7 ഇഞ്ച് |
വാറൻ്റിയും പിന്തുണയും
Warranty information for your Easy Core 125 Series Flux Core Welder is typically provided with the product packaging or can be obtained directly from the manufacturer or authorized dealer. Please retain your proof of purchase for warranty claims.
For technical support, parts, or service, please contact the manufacturer's customer service department or your local authorized service center. Refer to the contact information provided in your product documentation.