AUTOOL LM 120

AUTOOL LM 120 Digital Manifold Gauge Meter User Manual

Model: LM 120

1. ആമുഖം

The AUTOOL LM120+ Refrigeration Digital Manifold Gauge Meter is an intelligent electronic instrument designed for the installation, testing, and maintenance of refrigeration equipment such as air conditioners, refrigerators, and cold storage units. It offers multiple test modes, intelligent digital display, and a built-in refrigerant database for efficient operation, making it a versatile tool for professionals.

AUTOOL LM 120 Digital Manifold Gauge Meter with hoses and clamps

Figure 1: AUTOOL LM 120 Digital Manifold Gauge Meter and accessories.

2. സജ്ജീകരണ ഗൈഡ്

Follow these steps to properly set up your AUTOOL LM 120 Digital Manifold Gauge Meter:

  1. പ്രാരംഭ സംസ്ഥാനം: Before operation, ensure both the low pressure (blue) and high pressure (red) valves on the manifold gauge are in the closed position.
  2. Connect Temperature Clamps: Connect the two temperature-test clamps to their respective sockets on the manifold gauge. These clamps are essential for accurate temperature readings during testing.
    Connecting temperature clamps to the manifold gauge

    Figure 2: Connecting the temperature clamps for high and low pressure temperature testing.

  3. പവർ ഓൺ: Press the power switch on the manifold gauge to turn on the device. The LCD display will illuminate, showing current readings and settings.
  4. ട്യൂബുകൾ ബന്ധിപ്പിക്കുക: Connect the blue, yellow, and red tubes to the corresponding ports on the manifold gauge. Ensure connections are secure to prevent leaks.
  5. Connect Refrigerant Quick Connectors: Attach the refrigerant quick connectors to the appropriate service ports on the refrigeration system (e.g., vehicle AC system). The red connector typically goes to the high-pressure port, and the blue to the low-pressure port.

Video 1: Demonstrates the setup and connection process for the AUTOOL LM 120 Digital Manifold Gauge Meter, including connecting temperature clamps and refrigerant tubes to a vehicle's AC system.

3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The AUTOOL LM 120 offers various functions for comprehensive refrigeration system analysis:

3.1 വാക്വം ഓപ്പറേഷൻ

To perform a vacuum operation, ensure all connections are secure. Open the necessary valves on the manifold gauge to initiate the vacuum process. The gauge will display the vacuum degree, allowing you to monitor the system's evacuation.

3.2. Refrigerant Filling

  1. Connect Refrigerant Container: After vacuuming, connect a new refrigerant container to the yellow service hose of the manifold gauge.
  2. Prepare Vehicle (if applicable): If working on a vehicle, start the engine and adjust the air conditioner to its lowest temperature setting to ensure the system is ready for refrigerant intake.
  3. Inlet Refrigerant: Slowly open the appropriate valves on the manifold gauge to allow the new refrigerant to enter the system. Monitor the pressure readings on the digital display to ensure proper filling.

3.3. Multiple Test Modes

The LM 120 supports various test modes:

  • Dual Pressure Measurement: Measures both high and low pressures simultaneously.
  • Dual Temperature Measurement: Measures high and low pipeline temperatures using the connected test clamps.
  • Vacuum Degree Measurement: ശതമാനം പ്രദർശിപ്പിക്കുന്നുtage of vacuum achieved.
  • Pressure Leakage Measurement: Calculates pressure difference over time to detect leaks.
  • യൂണിറ്റ് പരിവർത്തനം: Easily switch between pressure units (Kpa, Mpa, bar, inHg, PSI) and temperature units (Celsius/Fahrenheit).
Evaporation Pressure and Temperature Test on AUTOOL LM 120

Figure 3: Display showing Evaporation Pressure & Temperature Test results.

Condensing Pressure and Temperature Test on AUTOOL LM 120

Figure 4: Display showing Condensing Pressure & Temperature Test results.

Pressure Leakage Test on AUTOOL LM 120

Figure 5: Display showing Pressure Leakage Test results.

3.4. Built-in Database

The LM 120 features a built-in database of 89 kinds of refrigerant pressure and evaporation temperatures. This allows the device to automatically calculate supercooling and superheating temperatures, providing convenient and direct access to critical operational data.

Refrigerant Type Setting and Observation Window on AUTOOL LM 120

Figure 6: Setting refrigerant type and observing filling status through the viewable window.

4. പരിപാലനം

Proper maintenance ensures the longevity and accuracy of your AUTOOL LM 120 Digital Manifold Gauge Meter:

  • വൃത്തിയാക്കൽ: Regularly wipe the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or casing.
  • സംഭരണം: After each use, carefully uninstall all quick connectors and tubes. Turn off the manifold gauge. Pack the equipment securely in its carrying case to protect it from dust, moisture, and physical damage.
  • ഘടക പരിശോധന: Periodically inspect the hoses, connectors, and temperature clamps for any signs of wear, cracks, or damage. Replace any worn components to maintain optimal performance and prevent refrigerant leaks.
  • ഈട്: The LM 120 is constructed with high-strength engineering plastic, flexible non-slip silicone, and copper interfaces, designed for industrial-grade durability. Proper handling and storage will further extend its service life.

5. പ്രശ്‌നപരിഹാരം

If you encounter issues with your AUTOOL LM 120, consider the following:

  • കൃത്യമല്ലാത്ത വായനകൾ: Ensure all connections are tight and free of leaks. Verify that the correct refrigerant type is selected in the device settings. If persistent, contact customer support for potential calibration needs.
  • Temperature Sensor Issues: Check the connection of the temperature clamps. Ensure they are securely attached to the pipes for accurate readings. If clamps are damaged, they may need replacement.
  • ഡിസ്പ്ലേ/പവർ ഇല്ല: Check battery levels. Ensure the power button is pressed firmly.
  • Hose Leaks: Inspect hoses and their connections for any visible damage or loose fittings. Tighten connections or replace hoses if necessary.
  • വാക്വം ഫംഗ്ഷൻ: Note that the LM 120 measures relative vacuum degree and does not display micron readings. If micron-level vacuum measurement is required, a different model may be necessary.

For issues not covered here, please refer to the detailed product manual or contact AUTOOL customer support.

6 സ്പെസിഫിക്കേഷനുകൾ

പരാമീറ്റർമൂല്യം
ഇനം മോഡൽ നമ്പർLM 120
നിർമ്മാതാവ്ഓട്ടോഓൾ
മെറ്റീരിയൽCrystal, Silicone
ഇനത്തിൻ്റെ അളവുകൾ L x W x H0.01 ഇഞ്ച്
ഇനത്തിൻ്റെ ഭാരം950 ഗ്രാം
സ്ക്രീൻ വലിപ്പം12 ഇഞ്ച്
Pressure Test Typeഉപരിതല മർദ്ദം
Pressure Test UnitsKpa; Mpa; bar; inHg; PSI
പ്രഷർ ടെസ്റ്റ് ശ്രേണി0 Kpa - 6000 Kpa
പ്രഷർ ടെസ്റ്റ് റെസല്യൂഷൻ1 Kpa
മർദ്ദ പരിശോധന കൃത്യത+/- 0.5%(FS)+ 5dgt
പ്രഷർ ഓവർലോഡ് പരിധി10000 Kpa (10 Mpa; 100 ബാർ;)
Vacuum Test TypeRelative vacuum
Vacuum Test UnitsKpa; Mpa; bar; inHg; PSI
വാക്വം ടെസ്റ്റ് ശ്രേണി-101 Kpa ~ 0 Kpa
വാക്വം ടെസ്റ്റ് റെസല്യൂഷൻ1 Kpa
Temperature Test Units°C (Celsius), °F (Fahrenheit)
താപനില പരിശോധന ശ്രേണി-40°C ~ 150°C (-40°F ~ 302°F)
താപനില പരിശോധന റെസല്യൂഷൻ0.1°C (-40°C ~ 99.9°C), 1°C (100°C ~ 150°C), 0.1°F (-40°F ~ 99.9°F), 1°F (100°F ~ 302°F)
താപനില പരിശോധന കൃത്യത+/- 0.5°C + 2dgt, +/- 0.9°F + 2dgt
Technical Parameters table for AUTOOL LM 120

Figure 7: Detailed technical parameters of the AUTOOL LM 120.

7. വാറൻ്റിയും പിന്തുണയും

AUTOOL stands behind the quality of its products:

  • മൂന്ന് വർഷത്തെ വാറന്റി: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years.
  • Lifelong Maintenance: The product is supported with lifelong maintenance.
  • ഉപഭോക്തൃ പിന്തുണ: For any inquiries or support needs, AUTOOL offers 24/7 customer support. You can contact them for assistance with product operation, troubleshooting, or warranty claims.
24/7 Customer Support icon3 വർഷത്തെ വാറന്റി ഐക്കൺ

Figure 8: AUTOOL's commitment to customer support and warranty.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.