POU Installation Rail without Filter (PRAILKIT)

The following information is provided to facilitate connecting a POU water cooler to mains water. If you are in any doubt, please consult a plumber or the building/facilities manager. The components in this kit have been selected to ensure that the installation complies with WRAS guidelines.

ഘടകം കഴിഞ്ഞുview

AA FIRST POU Installation Rail without Filter 0

15mm brass compression equal Tee piece (CONT15)
15mm brass compression equal elbow piece (CONE15)
15mm copper tubing (10cm length) (TUBECOP1510)
15mm compression double check valve & isolation tap (വിസിഡി)
Pressure reducing valve (set at 2.5 – 3bar) (PRV)
Water block & non-return valve  (WBLOC)
¾” BSP to ¼” John Guest pushfit reducer (REDU3414)
How to connect the PFRAILKIT
  1. Isolate water supply at stop cock or isolation valve.
  2. Cut the copper pipe leaving enough room to install the Tee piece, or elbow piece if the mains pipe is in a vertical position. The cut piece of copper can be used to connect the brass Tee or elbow piece to the double check valve. It is recommended to use support clips for pipe work.
  3. Install the PRAILKIT components in the order shown in the picture.
  4. Check that the water block has been installed vertically with the flow direction pointing down.
  5. Thoroughly check all pipe work before commissioning and leaving site.
About the Water Block

The water block is designed to prevent large scale flooding by limiting the amount of water (dependant on the setting) that passes through in one flow. The water block should be installed in a vertical position with the flow direction pointing down. To set the flow meter on the water block, use the white key provided to move the arrow to number 1 on the inside of the rim. This will limit the flow to 4.5ltrs. If the arrow points to `2′, the flow will be limited to 9ltrs and so on. If the water block shuts the water off, the pink button in the centre of the block will pop out. Simply depress the button to reset.

AA FIRST POU Installation Rail without Filter 1

AA FIRST എന്നത് CIRCON LTD യുടെ ഒരു ഡിവിഷനാണ്: ഇംഗ്ലണ്ടിൽ രജിസ്റ്റർ ചെയ്തത് 5121722 എന്ന നമ്പറിൽ.

യുകെ ആസ്ഥാനം:

സീഡാർ ഹൗസ്
ഗ്രേഞ്ച് ഫാം
ലോങ്ങ് ലെയ്ൻ
Newbury, RG14 2TF
T: +44 (0) 1635 202489
E: enquiries@aafirst.co.uk
W: aafirst.co.uk (എ.എഫ്.സി)

ഫ്രഞ്ച് ആസ്ഥാനം:

T: +33 (0) 674 437 445
E: derek@aafirst.eu എന്ന വിലാസത്തിൽ ഇമെയിൽ അയയ്ക്കുക.
W: aafirst.fr (ആദ്യം)
W: aafirst.de (ആദ്യം)

T: +33 (0) 670 817 660
E: marike@aafirst.eu
W: aafirst.fr (ആദ്യം)
W: aafirst.de (ആദ്യം)

AA FIRST logo

പ്രമാണങ്ങൾ / വിഭവങ്ങൾ

AA FIRST POU Installation Rail without Filter [pdf] നിർദ്ദേശ മാനുവൽ
PRAILKIT, POU Installation Rail without Filter, Installation Rail without Filter, Rail without Filter, Filter

റഫറൻസുകൾ

ഒരു അഭിപ്രായം ഇടൂ

നിങ്ങളുടെ ഇമെയിൽ വിലാസം പ്രസിദ്ധീകരിക്കില്ല. ആവശ്യമായ ഫീൽഡുകൾ അടയാളപ്പെടുത്തി *