Mypin DA8-RRB

മൈപിൻ DA8-RRB ഡിജിറ്റൽ സെൻസർ മീറ്റർ നിർദ്ദേശ മാനുവൽ

2 റിലേ അലാറം ഔട്ട്പുട്ടുള്ള മൾട്ടി-ഫങ്ഷണൽ ഇന്റലിജന്റ് LED ഡിസ്പ്ലേ

1. ആമുഖം

The Mypin DA8-RRB is a versatile digital sensor meter designed for precise measurement of current or voltage signals. It supports input ranges of 0-75mV, 4-20mA, and 0-10V, making it compatible with a wide array of sensor devices including 2-wire transformers, pressure sensors, 4-wire weighing sensors, remote pressure meter resistance transmitters, potentiometers, and transducers. This intelligent meter features a stable performance, easy operation, and a clear 4-digit LED display for accurate readings.

ഫ്രണ്ട് view of the Mypin DA8-RRB Digital Sensor Meter
ഫ്രണ്ട് view of the Mypin DA8-RRB Digital Sensor Meter, showing the LED display and control buttons.

2. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Proper installation and wiring are crucial for the correct functioning of the DA8-RRB sensor meter. Ensure all power is disconnected before proceeding with installation.

2.1 മൗണ്ടിംഗ്

The meter is designed for panel mounting. Use the provided mounting clips to secure the device into a panel cutout of appropriate dimensions (refer to specifications for size). Ensure a snug fit to prevent movement and maintain environmental protection.

വശം view of the Mypin DA8-RRB Digital Sensor Meter with mounting clips
വശം view of the sensor meter, illustrating the mounting clips for panel installation.

2.2 വയറിംഗ് കണക്ഷനുകൾ

The rear panel of the meter features a terminal block for all electrical connections. Carefully identify each terminal before wiring. Refer to the diagram below for connection points:

പിൻഭാഗം view of the Mypin DA8-RRB Digital Sensor Meter showing terminal block
പിൻഭാഗം view of the sensor meter, displaying the terminal block with wiring labels for power, auxiliary power, alarm outputs, and input signals.

ടെർമിനൽ വിവരണങ്ങൾ:

  • Power Supply (90-265V AC/DC): Connect the main power supply to the designated terminals.
  • Auxiliary Power Supply (24V DC): Provides power for external sensors or transducers.
  • അലാറം ഔട്ട്‌പുട്ടുകൾ (AL1, AL2): Two relay alarm outputs. These are Normal Open (NO) contacts, rated AC250V/3A or DC 30V/3A.
  • Analog Output (OUT): Provides a 4-20mA analog output signal.
  • Input Signals (com, mV, mA, V): Connect your sensor's output signal to the appropriate input terminals based on whether it's a mV, mA, or V signal, ensuring the common (com) terminal is correctly wired.

Ensure all connections are secure and correctly polarized to prevent damage to the device or connected equipment.

3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The Mypin DA8-RRB features a user-friendly interface with a digital display and control buttons for easy configuration and monitoring.

3.1 ഫ്രണ്ട് പാനൽ നിയന്ത്രണങ്ങൾ

  • PV (Process Value) Display: Shows the current measured input value.
  • എസ്‌വി (സെറ്റ് വാല്യൂ) ഡിസ്പ്ലേ: Shows the setpoint or parameter value during configuration.
  • SET ബട്ടൺ: പാരാമീറ്റർ ക്രമീകരണ മോഡിൽ പ്രവേശിച്ച് തിരഞ്ഞെടുപ്പുകൾ സ്ഥിരീകരിക്കാൻ ഉപയോഗിക്കുന്നു.
  • << / RST Button: Used to shift digits during parameter setting or to reset certain functions.
  • Up Arrow (▲) Button: മൂല്യങ്ങൾ വർദ്ധിപ്പിക്കാനോ മെനു ഓപ്ഷനുകളിലൂടെ നാവിഗേറ്റ് ചെയ്യാനോ ഉപയോഗിക്കുന്നു.
  • Down Arrow (▼) Button: മൂല്യങ്ങൾ കുറയ്ക്കാനോ മെനു ഓപ്ഷനുകളിലൂടെ നാവിഗേറ്റ് ചെയ്യാനോ ഉപയോഗിക്കുന്നു.

3.2 LED സൂചകങ്ങൾ

  • AL1: Illuminates when Alarm 1 is active.
  • AL2: Illuminates when Alarm 2 is active.
  • പുറത്ത്: Illuminates when the analog output is active or a control output is triggered.

3.3 അടിസ്ഥാന പ്രവർത്തനം

Upon powering on, the meter will display the current Process Value (PV). To configure parameters such as input type, alarm setpoints, or output scaling, press the SET button to enter the programming menu. Use the Up/Down arrow buttons to navigate through parameters and adjust values. The << / RST button can be used to shift the cursor for precise numerical input. Press SET again to confirm changes and exit the menu.

4 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
മോഡൽഡിഎ8-ആർആർബി
ഇൻപുട്ട് സിഗ്നൽ0-75mV, 4-20mA, 0-10V
വൈദ്യുതി വിതരണം90-265V എസി/ഡിസി
ഓക്സിലറി പവർ സപ്ലൈ24V DC
വൈദ്യുതി ഉപഭോഗം<3W
കൃത്യത0.3%F.S±2dgt
Sampലിംഗ് നിരക്ക്≤8 തവണ/സെക്കൻഡ്
അലാറം ഔട്ട്പുട്ട്RELAY: Normal Open AC250V/3A or DC 30V/3A COS=1
അനലോഗ് ഔട്ട്പുട്ട്4-20mA
ഇനത്തിൻ്റെ വലിപ്പം48 മിമി (ഡബ്ല്യു) x 96 എംഎം (എച്ച്) x 80 എംഎം (ഡി)
ഇനത്തിൻ്റെ ഭാരം171g / 6.03oz
മെറ്റീരിയൽഎബിഎസ്
ഉത്ഭവംമെയിൻലാൻഡ് ചൈന

5. പരിപാലനം

To ensure the longevity and accurate performance of your Mypin DA8-RRB sensor meter, follow these simple maintenance guidelines:

  • വൃത്തിയാക്കൽ: Regularly wipe the exterior of the device with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the display or casing.
  • പരിസ്ഥിതി വ്യവസ്ഥകൾ: Operate and store the meter within its specified environmental conditions (temperature, humidity) to prevent damage. Avoid exposure to excessive dust, moisture, or corrosive environments.
  • പരിശോധന: Periodically check wiring connections for looseness or signs of corrosion. Ensure the mounting is secure.

6. പ്രശ്‌നപരിഹാരം

If you encounter issues with your Mypin DA8-RRB sensor meter, consider the following basic troubleshooting steps:

  • ഡിസ്പ്ലേ/പവർ ഇല്ല: Check the main power supply connections (90-265V AC/DC) and ensure power is being supplied. Verify the power cable is not damaged.
  • തെറ്റായ വായനകൾ: Double-check the input signal wiring (0-75mV, 4-20mA, 0-10V) to ensure it matches the sensor output and is connected to the correct terminals. Verify that the meter's input type setting matches your sensor's output. Ensure the sensor itself is functioning correctly.
  • അലാറം ട്രിഗർ ചെയ്യുന്നില്ല: Confirm that the alarm setpoints (AL1, AL2) are correctly configured and that the process value is reaching the setpoint. Check the wiring of the alarm relay outputs.
  • No Analog Output: Verify the 4-20mA analog output wiring and ensure the output scaling parameters are correctly set in the meter's configuration.

ഈ പരിശോധനകൾ നടത്തിയതിന് ശേഷവും പ്രശ്നങ്ങൾ നിലനിൽക്കുന്നുണ്ടെങ്കിൽ, കൂടുതൽ സഹായത്തിനായി ഉപഭോക്തൃ പിന്തുണയുമായി ബന്ധപ്പെടുക.

7 ഉപയോക്തൃ നുറുങ്ങുകൾ

  • Always ensure the meter is calibrated correctly for your specific sensor and application to achieve the most accurate readings.
  • Before making any wiring changes, always disconnect power to prevent electrical shock or damage to the device.
  • Keep a record of your configuration settings, especially after making changes, to easily revert if needed.

8. വാറൻ്റിയും പിന്തുണയും

For detailed warranty information and customer support, please refer to the seller's terms and conditions or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

അനുബന്ധ രേഖകൾ - ഡിഎ8-ആർആർബി

പ്രീview മൈപിൻ ഡി സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ | സ്പെസിഫിക്കേഷനുകളും വയറിംഗും
MYPIN D സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്ററിനായുള്ള സമഗ്ര നിർദ്ദേശ മാനുവൽ. DM8A, DK8A, DM8E തുടങ്ങിയ മോഡലുകളുടെ സ്പെസിഫിക്കേഷനുകൾ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണം, വയറിംഗ് ഡയഗ്രമുകൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview മൈപിൻ എൽഎം സീരീസ് വെയ്റ്റിംഗ് കൺട്രോളർ ഇൻസ്ട്രക്ഷൻ മാനുവലും മോഡ്ബസ് ഉപയോക്തൃ നിർദ്ദേശങ്ങളും
MYPIN LM സീരീസ് വെയ്റ്റിംഗ് കൺട്രോളറിനായുള്ള സമഗ്ര ഗൈഡ്, ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, മോഡ്ബസ് കമ്മ്യൂണിക്കേഷൻ പ്രോട്ടോക്കോളുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു. വിശദമായ സ്പെസിഫിക്കേഷനുകൾ, ഓർഡർ വിവരങ്ങൾ, മൗണ്ടിംഗ് അളവുകൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview മൈപിൻ എഫ്എച്ച് സീരീസ് ഇന്റലിജന്റ് മീറ്ററുകൾ: ഫ്രീക്വൻസി, ടാക്കോ, കൗണ്ടിംഗ്, ബാച്ച് - സാങ്കേതിക സവിശേഷതകൾ
MYPIN FH സീരീസ് ഇന്റലിജന്റ് മീറ്ററുകൾക്കായുള്ള സമഗ്രമായ സാങ്കേതിക സവിശേഷതകൾ, സവിശേഷതകൾ, പ്രവർത്തന രീതികൾ, ഫ്രീക്വൻസി, ടാക്കോ, കൗണ്ടിംഗ്, ബാച്ച് ഫംഗ്ഷനുകൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. ഈ പ്രമാണം അളവുകൾ, പാരാമീറ്ററുകൾ, കണക്ഷൻ ഡയഗ്രമുകൾ എന്നിവ വിശദമായി വിവരിക്കുന്നു.
പ്രീview മൈപിൻ ഡിഡബ്ല്യു സീരീസ് സിംഗിൾ ഫേസ് പവർ മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ - സാങ്കേതിക ഗൈഡ്
MYPIN DW സീരീസ് സിംഗിൾ-ഫേസ് പവർ മീറ്ററിനായുള്ള സമഗ്രമായ നിർദ്ദേശ മാനുവൽ. കൃത്യമായ വൈദ്യുത അളവെടുപ്പിനുള്ള സ്പെസിഫിക്കേഷനുകൾ, പ്രവർത്തനം, വയറിംഗ് ഡയഗ്രമുകൾ, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, ആപ്ലിക്കേഷനുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview MYPIN FH സീരീസ് കൗണ്ടർ/നീളം/ബാച്ച് മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ
കൗണ്ടർ, ദൈർഘ്യം, ബാച്ച് മീറ്ററുകൾ എന്നിവയുടെ MYPIN FH സീരീസിനായുള്ള നിർദ്ദേശ മാനുവൽ. FH4, FH7, FH8 മോഡലുകൾക്കുള്ള സ്പെസിഫിക്കേഷനുകൾ, സവിശേഷതകൾ, ക്രമപ്പെടുത്തൽ, പ്രവർത്തനം, ഇൻപുട്ട്/ഔട്ട്പുട്ട് മോഡുകൾ, ടെർമിനൽ കണക്ഷനുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview MYPIN FH/FC സീരീസ് ഡിജിറ്റൽ കൗണ്ടറും ലെങ്ത് മീറ്ററും - സ്പെസിഫിക്കേഷനുകളും മാനുവലും
MYPIN FH/FC സീരീസ് ഡിജിറ്റൽ കൗണ്ടറുകൾക്കും നീള മീറ്ററുകൾക്കുമുള്ള സമഗ്രമായ മാനുവൽ. FH4, FH6, FH7, FH8, FH9, FH10 മോഡലുകൾക്കുള്ള വിശദമായ സ്പെസിഫിക്കേഷനുകൾ, ഓർഡറിംഗ് കോഡുകൾ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, ടെർമിനൽ കണക്ഷനുകൾ.