Senyang Alternating Pressure Anti-Bedsore Air Medical Mattress

Model: T05+P06C

1. ആമുഖം

This manual provides essential information for the safe and effective use of your Senyang Alternating Pressure Anti-Bedsore Air Medical Mattress, Model T05+P06C. This system is designed to aid in the prevention and treatment of pressure ulcers (bedsores) by continuously changing pressure points, promoting blood circulation, and enhancing patient comfort. Please read this manual thoroughly before setup and operation to ensure proper usage and to maximize the benefits of the product.

2. പാക്കേജ് ഉള്ളടക്കം

Carefully unpack all components and verify that all items are present and undamaged. If any items are missing or damaged, please contact customer support immediately.

  • Air Mattress (80"L x 34"W x 4.5"H, 18 cells)
  • Air Pump (Control Unit)
  • റിപ്പയർ കിറ്റ്
Components of the Senyang Alternating Pressure Mattress system, including the air mattress, air pump, and repair kit.
Figure 2.1: Complete Product Information - Air Mattress, Repair Kit, and Air Pump.

3 സ്പെസിഫിക്കേഷനുകൾ

The following table outlines the key specifications for the Senyang Alternating Pressure Anti-Bedsore Air Medical Mattress system:

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ് നാമംസെൻയാങ്
മോഡൽ നമ്പർT05+P06C
മെത്ത അളവുകൾ80"L x 34"W x 4.5"H (18 cells)
എയർ സെൽ മെറ്റീരിയൽMedical grade Nylon TPU
കവർ മെറ്റീരിയൽStretched PU, waterproof
ഭാരം ശേഷി150 കി
പമ്പ് വലുപ്പം27.5L x 12W x 10H സെ.മീ
Pump Cycle Time6 / 9 / 12 / 25 minutes (adjustable)
എയർ ഔട്ട്പുട്ട്More than 6 Liter/min
സമ്മർദ്ദ ശ്രേണി14mmHg - 62mmHg
ഫീച്ചറുകൾFoldable, Care Mattress
അപേക്ഷആശുപത്രി
വാറൻ്റിMattress: 1 year, Pump: 2 years

4. സജ്ജീകരണ നിർദ്ദേശങ്ങൾ

Follow these steps to properly set up your alternating pressure mattress system:

  1. കിടക്ക ഒരുക്കുക: Place the mattress on a standard hospital bed frame. Ensure the bed surface is clean and free of sharp objects.
  2. മെത്ത സ്ഥാപിക്കുക: Lay the air mattress flat on the bed frame. Ensure the foot end of the mattress aligns with the foot end of the bed. The air hoses should be positioned towards the foot end.
  3. Secure the Mattress: If your mattress has straps or ties, secure it to the bed frame to prevent shifting.
  4. പമ്പ് സ്ഥാപിക്കുക: Hang the air pump (control unit) securely at the foot end of the bed, typically on the bed rail, using the integrated hooks. Ensure it is stable and not prone to falling.
  5. എയർ ഹോസുകൾ ബന്ധിപ്പിക്കുക: Connect the air hoses from the mattress to the corresponding air outlets on the pump. Ensure connections are firm and secure to prevent air leakage. The image below shows the mattress and pump connected.
  6. പവർ ബന്ധിപ്പിക്കുക: Plug the pump's power cord into a grounded electrical outlet.
  7. Initial Inflation: Turn on the pump using the power switch. The mattress will begin to inflate. Allow approximately 20-30 minutes for the mattress to fully inflate and stabilize before placing a patient on it.
Senyang alternating pressure mattress and pump connected and ready for use.
Figure 4.1: Mattress and Pump Connected.
പിൻഭാഗം view of the air pump showing air hose connections and power input.
ചിത്രം 4.2: പിൻഭാഗം view of the Air Pump with connections.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Once the mattress is inflated, you can adjust the settings on the control unit to suit the patient's needs.

5.1 കൺട്രോൾ പാനൽ ഓവർview

The pump's control panel features various buttons and indicators for managing the mattress's functions.

Close-up of the air pump control panel with buttons for Panel Lock, Static/Initiating, Auto Firm, Alarm Reset, and cycle time/pressure adjustments.
Figure 5.1: Air Pump Control Panel.

5.2 പ്രധാന പ്രവർത്തനങ്ങൾ

  • വൈദ്യുതി സ്വിച്ച്: Located on the side or back of the pump, turns the unit ON/OFF.
  • സമ്മർദ്ദ ക്രമീകരണം: Use the pressure control dial or buttons to set the desired pressure range (14mmHg - 62mmHg). Adjust according to patient comfort and clinical guidelines.
  • സൈക്കിൾ സമയം: Select the alternating cycle time (6, 9, 12, or 25 minutes) using the dedicated button or dial. This determines how frequently the pressure in the air cells alternates.
  • പാനൽ ലോക്ക്: Activates or deactivates the control panel lock to prevent accidental changes to settings.
  • Static/Initiating Mode: This mode typically provides constant low pressure for patient transfers or when alternating pressure is not desired. 'Initiating' may refer to the initial inflation phase.
  • Auto Firm: Provides maximum inflation for a firm surface, useful for patient repositioning or care procedures.
  • അലാറം റീസെറ്റ്: Silences any active alarms (e.g., low pressure alarm). Address the cause of the alarm before resetting.

5.3 പൊതു പ്രവർത്തനം

  1. After initial inflation, adjust the pressure setting to a comfortable level for the patient, ensuring adequate support without bottoming out.
  2. Select an appropriate cycle time. Shorter cycles provide more frequent pressure changes.
  3. Monitor the patient regularly for comfort and skin integrity. Adjust settings as needed.
  4. ഒരു പവർ ഈtage, the mattress will slowly deflate. Ensure alternative care plans are in place.

6. പരിപാലനം

Regular maintenance ensures the longevity and optimal performance of your mattress system.

6.1 വൃത്തിയാക്കൽ

  • മെത്ത കവർ: The stretched PU, waterproof cover can be wiped down with a mild disinfectant solution. Ensure the cover is completely dry before use. Do not immerse the mattress or pump in water.
  • എയർ പമ്പ്: പരസ്യം ഉപയോഗിച്ച് പമ്പിൻ്റെ പുറംഭാഗം തുടയ്ക്കുകamp തുണി. ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.

6.2 Leak Checks and Inspection

Periodically inspect the mattress and hoses for any signs of wear, punctures, or leaks.

  • ഹോസ് പരിശോധന: Check air hoses for leaks when they are ready for use.
  • Mattress Inflation Check: The manufacturer performs a full check on mattresses with a 24-hour air inflation inspection to ensure quality. Users should also periodically check for consistent inflation.
Images showing process inspection for leaks in air pipes and a full 24-hour air inflation inspection for mattresses.
Figure 6.1: Process and Finished Product Inspection details, including leak checks and 24-hour inflation tests.

6.3 റിപ്പയർ കിറ്റ് ഉപയോഗം

Use the provided repair kit for minor punctures in the air mattress. Follow the instructions included with the repair kit for proper application.

7. പ്രശ്‌നപരിഹാരം

If you encounter issues with your mattress system, refer to the following common problems and solutions:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പമ്പ് ഓണാക്കുന്നില്ലവൈദ്യുതി വിതരണം ഇല്ലCheck power cord connection and wall outlet. Ensure power switch is ON.
Mattress not inflating or losing pressureLoose hose connection, puncture in mattress/hoses, pump malfunctionEnsure all hose connections are secure. Inspect mattress and hoses for visible damage; use repair kit for small punctures. If problem persists, contact support.
പമ്പ് ശബ്ദായമാനമാണ്Normal operation, pump not placed on a stable surfaceSome noise is normal. Ensure pump is securely hung or placed on a flat, stable surface to minimize vibration.
അലാറം മുഴങ്ങുന്നുLow pressure, power failureCheck for leaks or power issues. Press 'Alarm Reset' after resolving the issue.

8. വാറൻ്റിയും പിന്തുണയും

Senyang is committed to providing high-quality products and excellent customer service.

8.1 ഉൽപ്പന്ന വാറന്റി

  • മെത്ത: വാങ്ങിയ തീയതി മുതൽ 1 വർഷത്തെ വാറന്റി.
  • പമ്പ്: വാങ്ങിയ തീയതി മുതൽ 2 വർഷത്തെ വാറന്റി.

സാധാരണ ഉപയോഗത്തിലുള്ള നിർമ്മാണ വൈകല്യങ്ങൾ ഈ വാറന്റി ഉൾക്കൊള്ളുന്നു. ദുരുപയോഗം, അപകടങ്ങൾ, അല്ലെങ്കിൽ അനധികൃത പരിഷ്കാരങ്ങൾ എന്നിവ മൂലമുള്ള നാശനഷ്ടങ്ങൾക്ക് ഇത് പരിരക്ഷ നൽകുന്നില്ല.

8.2 ഉപഭോക്തൃ പിന്തുണ

For any questions regarding the use, maintenance, or troubleshooting of your Senyang mattress system, please contact our customer service team.

  • We provide online guidance for product usage inquiries.
  • Complaints are handled within 24 hours.
  • Within a reasonable range, free parts can be delivered by courier.
Customer service representative with a headset, indicating support availability.
Figure 8.1: Customer Service Support.

8.3 Quality Assurance and Certifications

Our products adhere to strict quality control standards and have obtained various system and quality certificates, including ISO13485, TUV, CE, and 510K, ensuring reliability and safety.

അനുബന്ധ രേഖകൾ - T05+P06C

പ്രീview T05 Bone Conduction Headset User Guide
User guide for the T05 Bone Conduction Headset, covering product features, key descriptions, charging, operation, troubleshooting, and specifications.
പ്രീview DEKO LIVING Infrared Tower Heater COH40007 Instruction Manual
Comprehensive instruction manual for the DEKO LIVING Infrared Tower Heater, model COH40007. Includes safety warnings, assembly instructions, operating procedures, maintenance tips, and specifications.
പ്രീview ലൂട്രോൺ ടേപ്പ് ലൈറ്റ് സൊല്യൂഷൻസ് ഇൻസ്റ്റലേഷൻ ഗൈഡ്
ലൂട്രോൺ ടേപ്പ് ലൈറ്റ് സൊല്യൂഷനുകൾക്കായുള്ള സമഗ്രമായ ഇൻസ്റ്റലേഷൻ നിർദ്ദേശങ്ങൾ, ഘടക ഇൻസ്റ്റാളേഷൻ, എൽഇഡി ടേപ്പ് സജ്ജീകരണം, പവർ ഇന്റർഫേസ് കണക്ഷൻ, വയർലെസ് കൺട്രോളർ കോൺഫിഗറേഷൻ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. ട്രബിൾഷൂട്ടിംഗും പൊതുവായ വിവരങ്ങളും ഉൾപ്പെടുന്നു.
പ്രീview ആർടെക്ക് MW167 വയർലെസ് മൗസ് യൂസർ മാനുവൽ - സജ്ജീകരണവും ഗൈഡും
ആർടെക്ക് MW167 വയർലെസ് മൗസിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ. ഉൽപ്പന്ന സവിശേഷതകൾ, ആരംഭിക്കൽ, ജോടിയാക്കൽ, ചാർജിംഗ്, DPI ക്രമീകരണങ്ങൾ, ട്രബിൾഷൂട്ടിംഗ്, വാറന്റി വിവരങ്ങൾ എന്നിവയെക്കുറിച്ച് അറിയുക.
പ്രീview UNI-T UT320A Mini Single Input Thermometer User Manual
User manual for the UNI-T UT320A Mini Single Input Thermometer, detailing features, operation, safety instructions, and technical specifications for K-type and J-type thermocouples.
പ്രീview UT320D Mini Single Input Thermometer User Manual | UNI-T
Comprehensive user manual for the UNI-T UT320D Mini Single Input Thermometer. Learn about features, operation, specifications, and safety instructions for this K/J thermocouple thermometer.