1. ഉൽപ്പന്നം കഴിഞ്ഞുview
This compact G1/4" liquid water flow sensor is designed to detect the flow of water in various applications, including water dispensers, purifiers, and vending machines. It operates on a simple magnetic displacement principle, activating a reed switch when water flows through it.
വീഡിയോ: ഒരു 360-ഡിഗ്രി view of the G1/4" water flow sensor, showcasing its compact design and connection points.

Image: The water flow sensor, illustrating the 'IN' and 'OUT' ports and the 2-point quick connection mechanism.

ചിത്രം: മുകളിൽ നിന്ന് താഴേക്ക് view of the water flow sensor, highlighting the directional 'IN' and 'OUT' markings.

ചിത്രം: താഴെ view of the sensor, indicating the internal flow direction with an arrow.
2. സവിശേഷതകൾ
- Magnetic Displacement Principle: When water flows, it displaces a magnet, which in turn activates a reed switch. When flow stops, the magnet returns to its original position, disconnecting the switch.
- ഒതുക്കമുള്ളതും ഭാരം കുറഞ്ഞതും: Designed for easy integration into various systems.
- സ്ഥിരതയുള്ള പ്രകടനം: Ensures reliable flow detection.
- Low Startup Flow: Activates at a minimum flow rate of 300ml/min.
- എളുപ്പമുള്ള ഇൻസ്റ്റാളേഷൻ: Features G1/4" thread and 2-point quick connections.
- നീണ്ടുനിൽക്കുന്ന നിർമ്മാണം: ദീർഘകാല ഉപയോഗത്തിനായി ഉയർന്ന നിലവാരമുള്ള പ്ലാസ്റ്റിക്കിൽ നിന്ന് നിർമ്മിച്ചത്.
- Normally Open Switch: The switch is open when there is no flow and closes when flow is detected.
3 സ്പെസിഫിക്കേഷനുകൾ
| ആട്രിബ്യൂട്ട് | മൂല്യം |
|---|---|
| മെറ്റീരിയൽ | പ്ലാസ്റ്റിക് |
| ശരീര വലുപ്പം (ഏകദേശം) | 6.2 x 2.8 x 1.6 സെ.മീ (2.4 x 1 x 0.63 ഇഞ്ച്) |
| ബാധകമായ ജലത്തിന്റെ ഗുണനിലവാരം | Turbidity < 1; Fe, Co & Ni < 0.3 Mg/L |
| ബാധകമായ ജല സമ്മർദ്ദം | ≤ 0.8 എംപിഎ |
| ബാധകമായ ജല താപനില | 5 ~ 50°C |
| അന്തരീക്ഷ ഈർപ്പം | ≤ 85% |
| സംഭരണ താപനില | -20 ~ 50 ഡിഗ്രി സെൽഷ്യസ് |
| ത്രെഡ് | ജി1/4" |
| Startup Flow | 300 മില്ലി / മിനിറ്റ് |
| പ്രതികരണ സമയം | ≤ 1 സെക്കൻഡ് |
| സ്വിച്ച് തരം | സാധാരണയായി തുറന്നിരിക്കുന്നു |
| വയറിൻ്റെ നീളം | 50 സെ.മീ |
| ഹൈഡ്രോസ്റ്റാറ്റിക് മർദ്ദം | Open at 1.05 MPa for 5 minutes (no leakage or damage) |
| വാല്യംtagഇ പ്രതിരോധം | DC160V for 1 min or DC200V for 1 sec (between live and non-live parts) |
| Maximum Closing Current | 0.5 എ |
| പരമാവധി ലോഡ് കറന്റ് | 1 എ |
| പ്രതിരോധത്തെക്കുറിച്ച് | 0.12 Ω |
| Disconnect Resistance | 10120 Ω |
| Power Connection Capacity | 0.2 പിഎഫ് |

Image: Detailed dimensional drawing of the water flow sensor.
4. സജ്ജീകരണം
- Identify Flow Direction: Locate the 'IN' and 'OUT' markings on the sensor body. Ensure the sensor is installed in the correct direction of water flow. An arrow indicating flow direction may also be present on the underside.
- വാട്ടർ ലൈനുകൾ ബന്ധിപ്പിക്കുക: Use the G1/4" threaded connections or the 2-point quick connections to integrate the sensor into your water system. Ensure all connections are secure and watertight to prevent leaks.
- വയറിംഗ്: The sensor has a 50cm wire with a connector. Connect this to your control circuit. As a 'Normally Open' switch, the circuit will be open (no signal) when there is no water flow, and it will close (signal detected) when water flows. Refer to your system's wiring diagram for proper integration.
- മൗണ്ടിംഗ്: Secure the sensor in place using the integrated mounting points and screws, if necessary, to prevent movement or strain on the connections.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The water flow sensor operates automatically based on the presence or absence of liquid flow. Once installed and wired correctly:
- When water flows through the sensor at or above the startup flow rate (300ml/min), the internal magnet is displaced, causing the reed switch to close. This completes the electrical circuit, sending a signal to your connected device (e.g., water dispenser controller).
- When water flow stops or drops below the startup flow rate, the magnet returns to its resting position due to spring thrust, opening the reed switch. This breaks the electrical circuit, indicating no flow.
The response time for flow detection is less than 1 second.
6. പരിപാലനം
To ensure optimal performance and longevity of your water flow sensor, follow these maintenance guidelines:
- പതിവ് പരിശോധന: Periodically check the sensor and its connections for any signs of wear, damage, or leaks.
- ജലത്തിൻ്റെ ഗുണനിലവാരം: Ensure the water flowing through the sensor meets the specified quality standards (turbidity < 1; Fe, Co & Ni < 0.3 Mg/L). Poor water quality can lead to sediment buildup and affect sensor accuracy or cause blockages.
- വൃത്തിയാക്കൽ: If sediment buildup is suspected, carefully disconnect the sensor and flush it with clean water. Avoid using harsh chemicals or abrasive materials that could damage the plastic body or internal components.
- സംഭരണം: If the sensor is to be stored for an extended period, ensure it is clean, dry, and kept within the specified storage temperature range (-20~50°C).
7. പ്രശ്നപരിഹാരം
- No Flow Detected (but water is flowing):
- Check if the sensor is installed in the correct flow direction ('IN' and 'OUT' markings).
- Verify that the water flow rate meets or exceeds the startup flow of 300ml/min.
- Inspect for any blockages within the sensor or connected pipes.
- Ensure the wiring connections are secure and correct.
- Constant Flow Detected (but water is not flowing):
- Check if the sensor is stuck in the 'closed' position due to debris or mechanical issue.
- Verify the wiring for any short circuits.
- കണക്ഷനുകളിലെ ചോർച്ച:
- Ensure all G1/4" threads are properly sealed with PTFE tape or appropriate sealant.
- Check quick connections for proper seating and O-ring integrity.
8 ഉപയോക്തൃ നുറുങ്ങുകൾ
- വാല്യംtage Clarification: This device is a passive flow switch, not a power-consuming electrical appliance. It does not 'handle' operating voltage in the same way a motor or light bulb does. Instead, it acts as a switch within a low-voltage control circuit. The 'Voltage Resistance' specification refers to the insulation capability between its internal components and external parts, ensuring safety when integrated into a circuit, not its operating voltage. It is designed to switch a circuit with a maximum load current of 1A.
- Installation Direction is Crucial: Always double-check the 'IN' and 'OUT' markings and any flow arrows to ensure correct installation. Incorrect orientation will prevent proper operation.
- Pre-filter for Longevity: If your water source has high particulate matter, consider installing a pre-filter to prevent debris from entering and potentially clogging the flow sensor.
9. വാറൻ്റിയും പിന്തുണയും
For any questions, technical assistance, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.