1. ആമുഖം
The NOYAFA NF-825TMR is a versatile 6-in-1 electrical kit designed for comprehensive circuit tracing and testing. This multifunction device includes a transmitter, a receiver, and an outlet tester, enabling users to trace circuits and electric wires, locate circuit breakers, detect wiring faults, test outlets, find network cables, and detect voltage. It is an essential tool for professionals and DIY enthusiasts alike, offering precision and safety in various electrical tasks.

Image: The NOYAFA NF-825TMR Transmitter and Receiver units.
2 സുരക്ഷാ വിവരങ്ങൾ
- Always read and understand this manual before operating the device.
- Do not use the device if it appears damaged or is not functioning correctly.
- Ensure proper insulation and personal protective equipment (PPE) when working with live circuits.
- Never attempt to open or modify the device. Refer all servicing to qualified personnel.
- ഉപകരണം വെള്ളത്തിൽ നിന്നും ഉയർന്ന താപനിലയിൽ നിന്നും അകറ്റി നിർത്തുക.
- നൽകിയിരിക്കുന്ന ആക്സസറികളും ചാർജിംഗ് കേബിളും മാത്രം ഉപയോഗിക്കുക.
3. പാക്കേജ് ഉള്ളടക്കം
പാക്കേജ് തുറക്കുമ്പോൾ, ഇനിപ്പറയുന്ന എല്ലാ ഇനങ്ങളും ഉൾപ്പെടുത്തിയിട്ടുണ്ടെന്ന് ദയവായി ഉറപ്പാക്കുക:
- Transmitter (1 pc)
- Receiver (1 pc)
- ഉപയോക്തൃ മാനുവൽ (1 പിസി)
- 825TMR Box (1 pc)
- 825TMR Kit (1 pc)
- Multimeter Adapter Cable (1 pc)
- Alligator Clip (1 pc)
- Exclusive Accessory Cable (1 pc)
- Type-C Charging Cable (1 pc)
- Quality Certificate (1 pc)

Image: The product box displaying the list of included accessories.
4. ഉൽപ്പന്നം കഴിഞ്ഞുview
The NF-825TMR consists of three main components: the Transmitter (NF-825T), the Receiver (NF-825R), and the Socket Test unit (NF-825M). Familiarize yourself with the buttons, ports, and indicators on each unit.

Image: Detailed diagram illustrating the buttons and ports on the Transmitter, Receiver, and Socket Test unit.
Transmitter (NF-825T)
- പവർ ബട്ടൺ: യൂണിറ്റ് ഓൺ/ഓഫ് ചെയ്യുന്നു.
- Scan/Live/Off Switch: Selects operating mode for tracing.
- പ്രകാശ സൂചകം: Shows power status and signal.
- ടൈപ്പ്-സി ചാർജിംഗ് പോർട്ട്: ആന്തരിക ബാറ്ററി ചാർജ് ചെയ്യുന്നതിന്.
- Network Cable Tracking Port (RJ45): For connecting network cables.
- Positive/Negative Electrodes: For connecting alligator clips.
Receiver (NF-825R)
- പവർ ബട്ടൺ: യൂണിറ്റ് ഓൺ/ഓഫ് ചെയ്യുന്നു.
- സെൻസിറ്റിവിറ്റി സ്വിച്ച്: Adjusts signal sensitivity (0-9).
- സിഗ്നൽ സൂചകം: LED lights (1-3) indicate signal strength.
- പവർ സൂചകം: പവർ സ്റ്റാറ്റസ് കാണിക്കുന്നു.
- സ്കാൻ ബട്ടൺ: Initiates scanning mode.
- Socket Button: Activates socket test mode.
- NCV Button: Activates Non-Contact Voltagഇ കണ്ടെത്തൽ.
- ലൈറ്റിംഗ് സ്വിച്ച്: LED ലൈറ്റ് ഓൺ/ഓഫ് ചെയ്യുന്നു.
- അന്വേഷണം: For detecting signals and voltage.
- ടൈപ്പ്-സി ചാർജിംഗ് പോർട്ട്: ആന്തരിക ബാറ്ററി ചാർജ് ചെയ്യുന്നതിന്.
Socket Test Unit (NF-825M)
- 3-pin Power Plug: For connecting to standard outlets.
- GFCI Button: Tests Ground Fault Circuit Interrupter functionality.
- സൂചകങ്ങൾ: LEDs show wiring status (Correct, Open Ground, Open Neutral, Open Hot, Live/NEU Rev, Live/GRD Rev, Open GRD).
5. സജ്ജീകരണം
5.1 ഉപകരണം ചാർജ് ചെയ്യുന്നു
Both the Transmitter and Receiver units are powered by a 7.4V 700mA lithium battery and feature a Type-C charging port. To charge:
- Connect the provided Type-C charging cable to the charging port on the Transmitter and/or Receiver.
- Plug the other end of the cable into a DC 5V 1A power adapter (not included).
- The power indicator will show charging status. Ensure both units are fully charged before use for optimal performance.

Image: Illustration of the Type-C charging process for the Transmitter and Receiver.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
6.1 Circuit Tracing (Live/Energized or Open/De-energized)
The NF-825TMR can trace live (energized) or open (de-energized) circuits, conduits, pipes, and single wires within a bundle. The probe and tone generator provide precise indications through various materials.
- For Live Circuits: Connect the Transmitter to the live circuit using the appropriate adapter cable and alligator clips. Set the Transmitter switch to 'Live'.
- For Open Circuits: Connect the Transmitter to the de-energized circuit. Set the Transmitter switch to 'Scan'.
- Turn on the Receiver and adjust the Sensitivity Switch (0-9) to an appropriate level.
- Move the Receiver's probe along the suspected path of the wire. The signal indicators and audible tone will guide you to the wire's location.

Image: Demonstrating the detection of hidden wires in a live circuit.
6.2 Circuit Breaker Finding
To locate the corresponding circuit breaker for an outlet:
- Plug the Socket Test unit into the desired outlet.
- Turn on the Receiver and set it to 'SCAN' mode.
- Move the Receiver's probe along the circuit breakers in the electrical panel. The Receiver will indicate the correct breaker with a strong signal and audible tone.

Image: Using the NF-825TMR to identify circuit breakers in an electrical panel.
6.3 GFCI Outlet Testing and Wiring Fault Detection
The Socket Test unit can detect common wiring problems and test GFCI receptacles:
- Plug the Socket Test unit directly into the outlet you wish to test.
- Observe the LED indicators on the Socket Test unit. They will illuminate to show the wiring status (e.g., Correct, Open Ground, Open Neutral, Open Hot, Live/NEU Rev, Live/GRD Rev, Open GRD).
- To test GFCI functionality, press the 'GFCI' button on the Socket Test unit. A working GFCI should trip, cutting power to the outlet.

Image: Performing a socket test and GFCI check with the NF-825TMR.
6.4 Network Cable Tracing (RJ45)
To locate network cables (CAT5/CAT6) with the Transmitter and Receiver:
- Set the Transmitter switch to 'SCAN' mode.
- Insert one end of the RJ45 network cable into the tracking port on the Transmitter.
- Turn on the Receiver and adjust sensitivity.
- Use the Receiver's probe to trace the network cable. The signal strength will increase as you approach the target cable.

Image: Using the Transmitter to locate a network cable.

Image: Tracing a network cable connected to a PoE switch.
6.5 എൻസിവി (നോൺ-കോൺടാക്റ്റ് വോളിയംtagഇ) കണ്ടെത്തൽ
The Receiver's probe can detect AC voltage without direct contact:
- റിസീവർ ഓണാക്കുക.
- Press the 'NCV' button to activate NCV mode.
- Bring the probe close to the object or wire you suspect carries voltage. The signal indicators and audible tone will activate if voltagഇ കണ്ടെത്തി.

Image: Using the NCV Induction Pen feature to detect voltage.
6.6 LED ലൈറ്റിംഗ്
The Receiver is equipped with an LED light for improved visibility in low-light conditions:
- Press the 'Lighting Switch' button on the Receiver to turn the LED light on or off.

Image: The Receiver's LED light illuminating a dark area.
6.7 സെൻസിറ്റിവിറ്റി അഡ്ജസ്റ്റ്മെന്റ്
The Receiver features a sensitivity switch to optimize detection based on the environment:
- Rotate the Sensitivity Switch (labeled 0-9) on the Receiver to increase or decrease the detection sensitivity. Adjust as needed to filter out interference or detect weaker signals.

Image: Diagram illustrating the Sensitivity Switch on the Receiver.
7. പരിപാലനം
- വൃത്തിയാക്കൽ: ഉണങ്ങിയതും മൃദുവായതുമായ തുണി ഉപയോഗിച്ച് ഉപകരണം തുടയ്ക്കുക. അബ്രാസീവ് ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
- സംഭരണം: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the device is fully charged before long-term storage.
- ബാറ്ററി: The device uses a rechargeable lithium battery. If the device will not be used for an extended period, charge it periodically to maintain battery health.
8. പ്രശ്നപരിഹാരം
- ഉപകരണം ഓണാക്കുന്നില്ല: ബാറ്ററി ചാർജ്ജ് ചെയ്തിട്ടുണ്ടെന്ന് ഉറപ്പാക്കുക. ഒരു ടൈപ്പ്-സി ചാർജറുമായി കണക്റ്റ് ചെയ്ത് വീണ്ടും ശ്രമിക്കുക.
- No signal detected during tracing: Check that the Transmitter is correctly connected and in the appropriate mode (Scan/Live). Adjust the Receiver's sensitivity. Ensure the circuit is active if tracing a live circuit.
- കൃത്യമല്ലാത്ത വായനകൾ: Ensure there is no strong electromagnetic interference nearby. Re-calibrate by moving away from potential interference sources and re-testing.
- Socket Test indicators not lighting up: Ensure the outlet has power. Check the Socket Test unit for any visible damage.
9 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | പരാമീറ്റർ |
|---|---|
| ഉൽപ്പന്ന മോഡൽ | NF-825TMR |
| Trace AC Power Cable | Trace Power Voltage Range: AC 90V~250V |
| Interface Type: Alligator clip | |
| Transmitter Distance: 200m | |
| Transmitter Frequency: 157KHz | |
| ആഴം കണ്ടെത്തൽ | 0~0.5മീ |
| കേബിൾ തരം | CAT5 / CAT6 |
| നെറ്റ്വർക്ക് കേബിൾ പരിശോധന | Network Interface Type: RJ45 |
| Transmitter Frequency: 455KHz | |
| Transmitter Distance: 600m | |
| Air Circuit Breaker Tracking | Transmitter Distance: 600m |
| Detecting Depth: 2~3cm | |
| Socket Cable Sequence Test | ടെസ്റ്റിംഗ് വോളിയംtage Range: AC 90V~250V, 50/60Hz |
| NCV Detecting | AC 90V~1000V, 50/60Hz |
| എൽഇഡി എൽamp | അതെ |
| വൈദ്യുതി വിതരണം | 7.4V 700mA ലിഥിയം ബാറ്ററി |
| പവർ അഡാപ്റ്റർ സ്പെസിഫിക്കേഷൻ | DC 5V/1A ടൈപ്പ്-സി |
| പ്രവർത്തന താപനില | 0~122°F (0~50°C) |
| പ്രവർത്തന ഈർപ്പം | ≤90% ഘനീഭവിക്കാത്തത് |
| സംഭരണ താപനില | 14~122°F (-10~50°C) |
| ട്രാൻസ്മിറ്റർ വലിപ്പം | 72 X 34 X 148 മിമി |
| റിസീവർ വലിപ്പം | 40 X 34 X 205 മിമി |

Image: Detailed product parameter table for the NF-825TMR.
10 ഉപയോക്തൃ നുറുങ്ങുകൾ
- For best results when tracing wires, ensure the area is free from excessive electromagnetic interference from other active devices.
- When using the NCV function, approach the suspected voltage source slowly to get an accurate reading and avoid false positives.
- Regularly check the battery levels of both the Transmitter and Receiver to avoid interruptions during critical tasks.
11. വാറൻ്റിയും പിന്തുണയും
NOYAFA products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided on the product packaging or the official NOYAFA webസൈറ്റ്. വാങ്ങിയതിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.