mypin DA8-RRB

mypin DA8-RRB ഡിജിറ്റൽ സെൻസർ മീറ്റർ നിർദ്ദേശ മാനുവൽ

Multi-Functional Intelligent LED Display with 2 Relay Alarm Output

1. ആമുഖം

The mypin DA8-RRB is a versatile digital sensor meter designed for precise measurement and monitoring of various industrial signals. It features a clear 4-digit LED display for Process Value (PV) and Set Value (SV), and supports multiple input types including 0-75mV, 4-20mA, and 0-10V. Equipped with two relay alarm outputs, this meter provides stable performance and is easy to operate, making it suitable for integration with a wide range of sensors such as transformers, pressure sensors, weighing sensors, and more.

2 സുരക്ഷാ വിവരങ്ങൾ

  • Always disconnect power before making any wiring connections or performing maintenance.
  • Ensure all wiring is done by qualified personnel and complies with local electrical codes.
  • വൈദ്യുതി വിതരണം വോളിയം പരിശോധിക്കുകtage matches the meter's specifications (90-265V AC/DC).
  • Avoid exposing the device to excessive moisture, dust, or extreme temperatures.
  • Do not attempt to open or repair the device yourself; refer to qualified service personnel.
  • വൈദ്യുതാഘാതം തടയാൻ ശരിയായ ഗ്രൗണ്ടിംഗ് ഉറപ്പാക്കുക.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

3.1 ഫ്രണ്ട് പാനൽ

Front panel of mypin DA8-RRB Digital Sensor Meter
Figure 1: Front panel showing PV/SV displays, control buttons, and alarm indicators (AL1, AL2, OUT).

The front panel features a large 4-digit LED display for the Process Value (PV) and a smaller 4-digit LED display for the Set Value (SV). Control buttons include SET, <<RST (Reset/Shift), Up arrow, and Down arrow for configuration and operation. Indicators for AL1, AL2 (Alarm 1, Alarm 2), and OUT (Output) are also present.

3.2 Rear Panel and Terminals

Rear panel with terminal block and wiring diagram
ചിത്രം 2: പിൻഭാഗം view of the meter, detailing the terminal block for power, input, and output connections, along with product specifications.

The rear panel houses the terminal block for all electrical connections, including power input, auxiliary power, sensor inputs, and relay outputs. A detailed wiring diagram is provided on the label for easy installation.

3.3 മൗണ്ടിംഗ് ക്ലിപ്പുകൾ

വശം view of the meter with mounting clips
ചിത്രം 3: വശം view showing the included mounting clips for panel installation.

The meter comes with mounting clips for secure panel installation. These clips slide into grooves on the side of the meter and are tightened to hold the unit in place.

4 സ്പെസിഫിക്കേഷനുകൾ

പരാമീറ്റർസ്പെസിഫിക്കേഷൻ
മോഡൽDA8-RRB
ഇൻപുട്ട് സിഗ്നൽ0-75mV, 4-20mA, 0-10V
വൈദ്യുതി വിതരണം90-265V എസി/ഡിസി
ഓക്സിലറി പവർ സപ്ലൈ24V DC
വൈദ്യുതി ഉപഭോഗം3W-ൽ കുറവ്
കൃത്യത0.3%F.S ±2dgt
Sampലിംഗ് നിരക്ക്≤8 times/second
അലാറം ഔട്ട്പുട്ട്2 x RELAY (Normal Open, AC250V/3A or DC 30V/3A COS=1)
അനലോഗ് ഔട്ട്പുട്ട്4-20mA (Wiring not explicitly shown on provided diagram)
അളവുകൾ (W x H x D)48mm x 96mm x 80mm
ഭാരം171 ഗ്രാം
മെറ്റീരിയൽഎബിഎസ്

5. സജ്ജീകരണം

5.1 ഇൻസ്റ്റലേഷൻ

  1. Prepare a panel cutout of appropriate dimensions for the meter (typically 45mm x 92mm, though not explicitly stated, this is standard for 48x96mm meters).
  2. Insert the meter into the panel cutout from the front.
  3. Slide the provided mounting clips into the grooves on the sides of the meter from the rear.
  4. Tighten the screws on the mounting clips to secure the meter firmly in the panel.

5.2 വയറിംഗ് ഡയഗ്രം

Detailed wiring diagram on the meter's rear label
Figure 4: Close-up of the wiring diagram on the rear label. Refer to this diagram for all electrical connections.

5.3 ടെർമിനൽ കണക്ഷനുകൾ

Refer to Figure 4 and the following instructions for correct wiring:

ടെർമിനൽ നം.വിവരണംകുറിപ്പുകൾ
1, 2Power Supply (90-265V AC/DC)Connect to main power source.
3, 4Auxiliary Power (24V DC)For external devices or sensors requiring 24V DC.
5, 6Alarm Output 1 (AL1)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
7, 8Alarm Output 2 (AL2)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
9Common (com.mV.mA.V)Common terminal for mV, mA, and V inputs.
10mV / mA InputConnect positive terminal of 0-75mV or 4-20mA sensor here.
11വാല്യംtagഇ ഇൻപുട്ട് (V)Connect positive terminal of 0-10V sensor here.
12പോസിറ്റീവ് (+)Typically for 4-wire sensors or external sensor power.

പ്രധാനപ്പെട്ടത്: Ensure correct polarity for all input signals. Incorrect wiring can damage the meter or sensor.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

6.1 പവർ ഓണാണ്

After completing all wiring, apply power to the meter. The LED displays will illuminate, showing the current Process Value (PV) and potentially a Set Value (SV).

6.2 ബട്ടൺ പ്രവർത്തനങ്ങൾ

  • സെറ്റ് ബട്ടൺ: Used to enter parameter setting mode and confirm selections.
  • <<RST button: Used to shift digits during value setting or to reset certain functions.
  • Up (↑) button: Used to increase values or navigate through menu options.
  • Down (↓) button: Used to decrease values or navigate through menu options.

6.3 Basic Operation (General)

While specific programming steps are not detailed in the provided information, typical operation involves:

  1. Viewing PV/SV: The main display shows the current Process Value (PV). The smaller display shows the Set Value (SV), which might be an alarm setpoint or other configured parameter.
  2. ക്രമീകരണ പാരാമീറ്ററുകൾ: Press the SET button to enter the parameter setting mode. Use the Up/Down arrows to select parameters and adjust their values. Use the <<RST button to shift between digits when setting numerical values. Press SET again to confirm and save changes.
  3. അലാറം പ്രവർത്തനം: The AL1 and AL2 indicators will light up when the measured PV exceeds or falls below their respective setpoints, triggering the corresponding relay outputs.

For detailed parameter configuration, refer to the full product manual (if available from the manufacturer) or contact technical support.

7. പരിപാലനം

  • വൃത്തിയാക്കൽ: ഡിസ്പ്ലേ സൌമ്യമായി തുടച്ചുമാറ്റി സി.asinമൃദുവായതും ഉണങ്ങിയതുമായ തുണി ഉപയോഗിച്ച് വൃത്തിയാക്കുക. അബ്രാസീവ് ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
  • കണക്ഷൻ പരിശോധന: എല്ലാ വയറിംഗ് കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും തുരുമ്പെടുക്കലിൽ നിന്ന് മുക്തമാണെന്നും ഉറപ്പാക്കാൻ ഇടയ്ക്കിടെ പരിശോധിക്കുക.
  • പരിസ്ഥിതി വ്യവസ്ഥകൾ: Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the life of the device.

8. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
മീറ്റർ പവർ ഓൺ ആകുന്നില്ല.വൈദ്യുതി വിതരണം ഇല്ല അല്ലെങ്കിൽ തെറ്റായ വയറിംഗ്.Check power connections (Terminals 1, 2) and ensure voltage is within 90-265V AC/DC.
Display shows "----" or erratic readings.Incorrect sensor wiring, sensor malfunction, or wrong input type selected.Verify sensor connections (Terminals 9-12) and ensure the sensor is functioning correctly. Check meter configuration for correct input signal type.
Alarm outputs (AL1/AL2) not activating.Alarm setpoints incorrect or relay wiring issue.Check alarm setpoints (SV) and ensure they are configured correctly relative to the PV. Verify wiring to external alarm devices (Terminals 5-8).
കൃത്യമല്ലാത്ത വായനകൾ.Sensor calibration issue or environmental interference.Calibrate the sensor if possible. Ensure the meter is not exposed to strong electromagnetic interference.

9 ഉപയോക്തൃ നുറുങ്ങുകൾ

  • Input Signal Selection: Before connecting your sensor, ensure the meter is configured for the correct input signal type (mV, mA, or V) to avoid incorrect readings or potential damage.
  • ലേബലിംഗ് മായ്ക്കുക: For complex setups, clearly label all wires connected to the terminal block to simplify future troubleshooting or maintenance.
  • ടെസ്റ്റ് അലാറങ്ങൾ: After setting alarm points, perform a test to ensure the relay outputs activate as expected.

10. വാറൻ്റിയും പിന്തുണയും

For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

അനുബന്ധ രേഖകൾ - DA8-RRB

പ്രീview മൈപിൻ ഡി സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ | സ്പെസിഫിക്കേഷനുകളും വയറിംഗും
MYPIN D സീരീസ് ഇന്റലിജന്റ് സെൻസർ മീറ്ററിനായുള്ള സമഗ്ര നിർദ്ദേശ മാനുവൽ. DM8A, DK8A, DM8E തുടങ്ങിയ മോഡലുകളുടെ സ്പെസിഫിക്കേഷനുകൾ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണം, വയറിംഗ് ഡയഗ്രമുകൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview മൈപിൻ ഡിഡബ്ല്യു സീരീസ് സിംഗിൾ ഫേസ് പവർ മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ - സാങ്കേതിക ഗൈഡ്
MYPIN DW സീരീസ് സിംഗിൾ-ഫേസ് പവർ മീറ്ററിനായുള്ള സമഗ്രമായ നിർദ്ദേശ മാനുവൽ. കൃത്യമായ വൈദ്യുത അളവെടുപ്പിനുള്ള സ്പെസിഫിക്കേഷനുകൾ, പ്രവർത്തനം, വയറിംഗ് ഡയഗ്രമുകൾ, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, ആപ്ലിക്കേഷനുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview മൈപിൻ എൽഎം സീരീസ് വെയ്റ്റിംഗ് കൺട്രോളർ ഇൻസ്ട്രക്ഷൻ മാനുവലും മോഡ്ബസ് ഉപയോക്തൃ നിർദ്ദേശങ്ങളും
MYPIN LM സീരീസ് വെയ്റ്റിംഗ് കൺട്രോളറിനായുള്ള സമഗ്ര ഗൈഡ്, ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, മോഡ്ബസ് കമ്മ്യൂണിക്കേഷൻ പ്രോട്ടോക്കോളുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു. വിശദമായ സ്പെസിഫിക്കേഷനുകൾ, ഓർഡർ വിവരങ്ങൾ, മൗണ്ടിംഗ് അളവുകൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview മൈപിൻ എഫ്എച്ച് സീരീസ് ഇന്റലിജന്റ് മീറ്ററുകൾ: ഫ്രീക്വൻസി, ടാക്കോ, കൗണ്ടിംഗ്, ബാച്ച് - സാങ്കേതിക സവിശേഷതകൾ
MYPIN FH സീരീസ് ഇന്റലിജന്റ് മീറ്ററുകൾക്കായുള്ള സമഗ്രമായ സാങ്കേതിക സവിശേഷതകൾ, സവിശേഷതകൾ, പ്രവർത്തന രീതികൾ, ഫ്രീക്വൻസി, ടാക്കോ, കൗണ്ടിംഗ്, ബാച്ച് ഫംഗ്ഷനുകൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു. ഈ പ്രമാണം അളവുകൾ, പാരാമീറ്ററുകൾ, കണക്ഷൻ ഡയഗ്രമുകൾ എന്നിവ വിശദമായി വിവരിക്കുന്നു.
പ്രീview MYPIN FH സീരീസ് കൗണ്ടർ/നീളം/ബാച്ച് മീറ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ
കൗണ്ടർ, ദൈർഘ്യം, ബാച്ച് മീറ്ററുകൾ എന്നിവയുടെ MYPIN FH സീരീസിനായുള്ള നിർദ്ദേശ മാനുവൽ. FH4, FH7, FH8 മോഡലുകൾക്കുള്ള സ്പെസിഫിക്കേഷനുകൾ, സവിശേഷതകൾ, ക്രമപ്പെടുത്തൽ, പ്രവർത്തനം, ഇൻപുട്ട്/ഔട്ട്പുട്ട് മോഡുകൾ, ടെർമിനൽ കണക്ഷനുകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview MYPIN FH/FC സീരീസ് ഡിജിറ്റൽ കൗണ്ടറും ലെങ്ത് മീറ്ററും - സ്പെസിഫിക്കേഷനുകളും മാനുവലും
MYPIN FH/FC സീരീസ് ഡിജിറ്റൽ കൗണ്ടറുകൾക്കും നീള മീറ്ററുകൾക്കുമുള്ള സമഗ്രമായ മാനുവൽ. FH4, FH6, FH7, FH8, FH9, FH10 മോഡലുകൾക്കുള്ള വിശദമായ സ്പെസിഫിക്കേഷനുകൾ, ഓർഡറിംഗ് കോഡുകൾ, പ്രവർത്തനം, പാരാമീറ്റർ ക്രമീകരണങ്ങൾ, ടെർമിനൽ കണക്ഷനുകൾ.