Aideepen XY12522

XY12522 CNC Adjustable DC Stabilized Voltagഇ പവർ സപ്ലൈ യൂസർ മാനുവൽ

Model: XY12522 | Brand: Aideepen

1. ആമുഖം

The XY12522 is a high-performance CNC adjustable direct current stabilized voltage power supply. It features constant voltage (CV) and constant current (CC) modes, a step-down module design, and supports advanced functionalities such as MPPT solar charging and serial communication via the standard MODBUS protocol. This device is built with top-quality materials, including an immersion gold plating display board for enhanced conductivity and durability, and an integrated flame-retardant injection-molded shell for safety.

XY12522 CNC Adjustable DC Stabilized Voltage Power Supply with control panel and module
Figure 1: XY12522 Power Supply Module and Control Panel. Displays input/output voltage, current, power, and storage groups.

2. സുരക്ഷാ മുൻകരുതലുകൾ

  • ഊർജ്ജ സ്രോതസ്സ്: Do NOT connect the input to AC power or 220V utility power.
  • വാല്യംtagഇ പരിധികൾ: പരമാവധി ഇൻപുട്ട് വോളിയംtage must not exceed 145V. It is recommended to operate within 140V.
  • ധ്രുവത: Ensure correct polarity. Reversing positive and negative poles will damage the device.
  • Reverse Irrigation Protection: The output does NOT have anti-reverse irrigation protection. When connecting a battery, ensure the power supply output voltage is always higher than the battery voltage. Alternatively, use a series diode for single conduction to prevent battery voltage reversal from damaging the power supply.
  • ബാറ്ററി ചാർജിംഗ്: Battery charging requires expertise. Non-professionals should not attempt direct battery charging to prevent fire and explosion.
  • Step-down Operation: This product is a step-down power supply. The maximum output voltage is approximately 94.5% of the input voltagഇ (ഇൻപുട്ട് വോളിയംtage * 0.945).

3 സ്പെസിഫിക്കേഷനുകൾ

പരാമീറ്റർമൂല്യം
ഉൽപ്പന്നത്തിൻ്റെ പേര്CNC DC Step-down Power Supply
മോഡൽ നമ്പർXY12522
ഇൻപുട്ട് വോളിയംtage12.00 വി ~ 140.0 വി
Putട്ട്പുട്ട് വോളിയംtage0 വി ~ 125.0 വി
ഔട്ട്പുട്ട് കറൻ്റ്0A ~ 22.00A
ഔട്ട്പുട്ട് പവർ2000W (പീക്ക്)
വാല്യംtagഇ റെസല്യൂഷൻ0.01V
റേറ്റുചെയ്ത ശേഷി<40VA
ഔട്ട്പുട്ട് തരംസിംഗിൾ
Storage Data Groups10 groups (Cd0 to Cd9)
പരിവർത്തന കാര്യക്ഷമത~95%
MPPT Solar Chargingപിന്തുണച്ചു
ആശയവിനിമയംSerial communication, standard MODBUS protocol, TTL level, onboard 485 communication
പ്രദർശിപ്പിക്കുക1.8-inch VA color LCD (38x29mm)
സർട്ടിഫിക്കേഷൻCE
Dimensions (Bare Board)119mm x 67.3mm x 43mm (ഏകദേശം)
Dimensions (Control Panel)81mm x 50mm x 40mm (ഏകദേശം)
പാക്കേജ് വലിപ്പം172mm x 95mm x 60mm (ഏകദേശം)
ഭാരം0.35 കി.ഗ്രാം (ഏകദേശം)
Product dimensions for the bare board and control panel, and package size.
Figure 2: Product and Package Dimensions.

4. ഘടകങ്ങളും സവിശേഷതകളും

The XY12522 power supply consists of a main module (bare board) and a control panel with an LCD display. Key features include:

  • Intelligent Temperature-Controlled Fan: For efficient heat dissipation.
  • Input Common-Mode Inductors: Reduce input power ripple for a low ripple output.
  • High-Power, High-Temperature Resistant Inductors: Iron-silicon-aluminum magnetic ring inductors for robust performance.
  • Output 2-Stage Filtering: For cleaner power output.
  • 10K NTC 3950B External Temperature Sensor Interface: For over-temperature protection and battery charging monitoring.
  • 0.3-10V Analog Control: Measurement range configurable via software (available in numerical control screen mode).
  • Independent Dual Serial Ports: Supports TTL level communication and onboard 485 communication simultaneously.
  • MPPT Hardware Switch: With an indicator light for MPPT activation.
  • Silicone Buttons: Provide comfortable touch and include indicator lights.
Internal components of the power supply module showing inductors, capacitors, fan, and various interfaces.
Figure 3: Internal Components and Key Features of the Power Supply Module.
Close-up of the control panel highlighting the immersion gold plating, flame-retardant shell, double-layer buckle design, and silicone buttons with indicators.
Figure 4: Control Panel Design and Button Features.
Diagram showing the functions of each button on the control panel: VSET, SW, I-SET, Encoder, and Power buttons.
Figure 5: Key Function Introduction for the Control Panel.

5. സജ്ജീകരണം

5.1 Bare Board Usage

The bare board can be used independently. When purchasing a bare device, switches, potentiometers, and dial switches will be welded on. If a set with a screen meter is purchased, these components are not welded by default.

Diagram of the XY12522 bare board, highlighting input/output terminals, serial communication interface, 485 communication interface, MPPT ON/OFF switch, and current dip switch settings.
Figure 6: XY12522 Bare Board Overview and Connection Points.

5.2 External Temperature Probe Connection

An external temperature probe can be connected to support over-temperature protection. Attach the external temperature probe to the battery (or other component to be monitored), and the system will automatically stop charging in case of over-temperature.

Diagram showing the connection of an external temperature probe to the NTC temperature probe interface on the power supply module, with a solar panel and battery setup.
Figure 7: MPPT Function and External Temperature Probe Connection.

6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

6.1 അടിസ്ഥാന പ്രവർത്തനം

  1. പവർ ഓൺ/ഓഫ്: Press the ON/OFF button to power on. Press and hold the ON/OFF button for 5 seconds to shut down.
  2. ക്രമീകരണം വോളിയംtagഇ (സിവി):
    • പ്രധാന യുഐയിൽ, ഹ്രസ്വമായി അമർത്തുക വി.എസ്.ഇ.ടി button. The LCD will display "SET" in the lower row, and "CV" will flash, indicating the voltage setting position is selected and blinking.
    • ഷോർട്ട് അമർത്തുക SW വോളിയം മാറുന്നതിനുള്ള ബട്ടൺ അല്ലെങ്കിൽ എൻകോഡർ ബട്ടൺtage setting position (digit).
    • Adjust the value by rotating the encoder.
    • After setting is complete, short press the വി.എസ്.ഇ.ടി പുറത്തുകടക്കാനും സംരക്ഷിക്കാനുമുള്ള ബട്ടൺ.
  3. Setting Current (CC):
    • ഷോർട്ട് അമർത്തുക ഐ-സെറ്റ് button. The setting steps are the same as for voltage.
Instructions for setting voltage and current on the power supply control panel.
Figure 8: Setting Voltagഇയും കറന്റും.

6.2 ഡിസ്പ്ലേ മോഡുകൾ

  1. ഇൻപുട്ട്/ഔട്ട്പുട്ട് വോളിയംtagഇ ഡിസ്പ്ലേ: പ്രധാന യുഐയിൽ, ഹ്രസ്വമായി അമർത്തുക SW button to switch between input and output voltagഇ ഡിസ്പ്ലേകൾ.
  2. Checking Power/Capacity/Energy/Time/Temperature: On the main UI, press the encoder button briefly to switch between displaying power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C) in rotation.
  3. കീ ലോക്ക്: പ്രധാന യുഐയിൽ, സെറ്റ് വോളിയം ലോക്ക് ചെയ്യുന്നതിന് എൻകോഡർ ബട്ടൺ 2 സെക്കൻഡ് അമർത്തിപ്പിടിക്കുകtage and current to prevent misoperation. Press and hold the encoder button for 2 seconds again after locking to unlock.
Screenshots showing input/output voltage display, cycling through power, capacity, energy, time, and temperature, and the key lock function.
Figure 9: Display Modes and Key Lock.

6.3 Data Group Function

This product has 10 data groups (Cd0 to Cd9). Press and hold the വി.എസ്.ഇ.ടി button on the main UI to access the data group UI. Rotate the encoder to call up the corresponding data group. You can press VSET/I-SET briefly to switch between constant voltage (CV) and constant current (CC) settings within a data group. After confirming the data group, press and hold the VSET/SW button or press the encoder button briefly to select the desired data group.

Screenshots showing how to set parameters within data groups, including voltage, current, and various protection values like undervoltagഇ, ഓവർ വോൾtage, overcurrent, overpower, overcapacity, overenergy, overtime, and overtemperature.
Figure 10: Set UI Parameter Settings within Data Groups.

6.4 System Parameter Settings

അമർത്തിപ്പിടിക്കുക SW button on the main interface to enter the settings menu. Press വി.എസ്.ഇ.ടി briefly to select the next parameter and press ഐ-സെറ്റ് briefly to select the previous parameter. After completing the settings, press and hold the SW/encoder button to exit the settings.

  • bEP Settings (Beeper Enable): Rotate the encoder to turn on/off the beeper. Selecting OFF will disable the beeper.
  • b-L Settings (LCD Brightness Adjustment): Rotate the encoder to adjust the brightness level (1-5 levels, factory default is level 5).
  • ZERO Setting (Current Zero Calibration): If there is a small current within 100mA when the output is not connected to a load, press and hold the power button to calibrate the zero point. Do not connect any load during calibration.
  • CLOF Setting (Force Power Output Off When Switching Data Sets): Rotate the encoder to select ON or OFF. ON: Power is forcibly turned off to prevent high voltage from damaging the load when switching data sets. OFF: Power switch state is maintained.
  • POFF (Shutdown Function): ON: Enable shutdown. Press and hold Power Key for 5 seconds to shut down. Click Power Key to start up. OFF: Disable shutdown.
  • RET Setting (Restore Factory Settings): Press and hold the power button until it stops blinking to restore factory settings.
  • C-F Settings (Choice between Celsius °C and Fahrenheit °F): Rotate the encoder to select 'C' or 'F'.
  • FET Settings (Quick Adjustment of Voltage, Current, or Power): Rotate the encoder to select CV/CC/OFF/CP. CV: Quickly adjust voltage. CC: Quickly adjust current. OFF: No action. CP: Quickly adjust power (when constant power is enabled).
  • Add Settings (Power Supply Address): Press the SW/encoder button briefly to select the bit, and rotate the encoder to adjust the numerical value (1-247, default 001). Used for serial communication.
  • bRE Settings (Communication Baud Rate Settings): Rotate the encoder to set different values from 0-8 (0:9600, 1:14400, ..., 6:115200, ..., 8:4800). Default baud rate is 115200 at level 6.
  • PPT Settings (MPPT Solar Charging Settings): Rotate the encoder to turn on/off the MPPT function. After enabling, press SW or encoder button briefly to switch to setting the maximum power point coefficient. Rotate the encoder to adjust the coefficient value between 0.75-0.85, with a default of 0.8.
  • CW Settings (Constant Power CW ON/OFF): To enable or disable the constant power CW function using a rotary encoder. After enabling constant power, press I-SET briefly on the main interface to modify the value of constant power.
  • WIFI Config (Need WF-POW module): Modify pairing mode with encoder. Options: Invalid Wifi, TOH (Touch Pair), AP (AP Pair), ROU (Connect Router), NET (NetWorking).
  • AnA Setting (Analog Control): ക്രമീകരിക്കാവുന്ന അനലോഗ് വോള്യംtage range from 2 to 10V. Can be self-configured.
  • UER View (Firmware Version Number): Displays the firmware version. The product supports firmware upgrades.
Screenshots of system parameter settings for Beeper Enable (bEP) and LCD Brightness Adjustment (b-L).
Figure 11: System Parameter Settings (Beeper and LCD Brightness).
Screenshots of system parameter settings for Celsius/Fahrenheit choice (C-F), Quick Adjustment (FET), and Power Supply Address (Add).
Figure 12: System Parameter Settings (Temperature Unit, Quick Adjustment, Address).
Screenshots of system parameter settings for Communication Baud Rate (bRE), MPPT Solar Charging (PPT), and Constant Power CW ON/OFF (CW).
Figure 13: System Parameter Settings (Baud Rate, MPPT, Constant Power).
Screenshots of system parameter settings for WIFI Config, Analog Control (AnA), and Firmware Version Number (UER).
Figure 14: System Parameter Settings (WIFI, Analog Control, Firmware Version).

6.5 CV/CC/CW Functions

The power supply operates in Constant Voltage (CV) and Constant Current (CC) modes. When the constant power function is turned on, it automatically switches based on the load.

  • കോൺസ്റ്റന്റ് വോളിയംtagഇ (സിവി): When the load current is less than the set constant current value, the power supply is in constant voltage mode. The output voltage എന്നത് സെറ്റ് വോളിയമാണ്tage value, and the current is adaptive.
  • സ്ഥിരമായ കറൻ്റ് (CC): When the load current exceeds the set constant current value, the power supply automatically enters constant current mode. The output current is the set constant current value, and the voltage is adaptive.
  • Constant Power (CW): സ്ഥിരമായ പവർ ഫംഗ്‌ഷൻ ഓണാക്കിയ ശേഷം, സ്ഥിരമായ നിലവിലെ മൂല്യം പരമാവധി മൂല്യത്തിലേക്കും സ്ഥിരമായ വോള്യത്തിലേക്കും സ്ഥിരസ്ഥിതിയായി മാറുന്നുtage value serves as the initial voltagഇ. അനുബന്ധ വാല്യംtage can be calculated based on Ohm's Law (R=U/I). The constant power point algorithm automatically follows, and constant power is achieved.
Diagram explaining the Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) functions and their operational principles.
Figure 15: Introduction to CV/CC/CW Functions.
Screenshots showing the product UI function details for Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) displays, as well as the display when the power is off.
Figure 16: Product UI Function Details.

6.6 Battery Charging Settings

  • bCH Settings (Battery Automatic Charging Threshold): Press the power button briefly to turn this function on or off (off by default). When the battery voltage falls below the set threshold, the power output is automatically activated to commence charging.
  • bTF Setting (Charge Cutoff Current): Press the power button briefly to turn this function on or off (off by default). After enabling, press the SW or encoder button briefly to select the digit and rotate the encoder to adjust the value in mA. If the charging current is less than the set value, it will be considered fully charged, and the output will be disconnected to prevent overcharging.
Screenshots of battery charging settings for automatic charging threshold (bCH) and charge cutoff current (bTF).
Figure 17: Battery Charging Settings.

7. കാലിബ്രേഷൻ

ഔട്ട്പുട്ട് വോള്യം ആണെങ്കിൽtage or current is inaccurate, you can calibrate it using the following steps:

  • CLU Setting (Calibrate Output Voltagഇ):
    1. Press and hold the power button to start calibration. "01" will be displayed.
    2. ഔട്ട്പുട്ട് വോള്യം അളക്കുകtage using a high-precision multimeter and input the actual voltage into the third line (SW shift operation is supported).
    3. Press the power button briefly to enter the second step of calibration. "02" will be displayed.
    4. Repeat step b.
    5. Press the power button again briefly, and "03" will be displayed. Wait for calibration to complete without any other operation. If successful, "SUC" will be displayed; if failed, "ERR" will be displayed.
  • CLA Setting (Calibrate Output Current):
    1. Connect a multimeter in current mode or an electronic load (the electronic load needs to be set to the maximum range of the product) directly to the output terminal.
    2. Press and hold the power button to start calibration, and "01" will be displayed. Input the actual current value from the multimeter or electronic load into the third line (SW shift operation is supported).
    3. Press the power button briefly to enter the second step of calibration. "02" will be displayed.
    4. Repeat step b.
    5. Press the power button again briefly, and "03" will be displayed. Wait for calibration to complete without any other operation. If successful, "SUC" will be displayed; if failed, "ERR" will be displayed.

കുറിപ്പ്: If calibration fails, you can try again. If you accidentally enter the calibration state, you can exit by pressing and holding the power button, and the parameters will not be saved after exiting.

Screenshots detailing the steps for calibrating output voltage (CLU) and output current (CLA) with visual indicators for each step.
ചിത്രം 18: ഔട്ട്പുട്ട് വോളിയംtage and Current Calibration.

8. Communication and Network Control

The XY12522 supports various communication methods for remote control and monitoring.

  • 485 ആശയവിനിമയം: Onboard 485 communication enables remote multi-machine control. With multi-serial port PC software, functions are more powerful. Communication control can be achieved with a separate bare board, providing a low-cost solution.
  • WiFi Module (Optional): Connect an XY-K485X module to achieve 485 bus control or connect a WiFi module to enable remote control via APP and web-based networking control.
  • 433M Wireless Remote Control Module (Optional): Can be connected to an infrared receiver module for efficient and fast remote control, allowing synchronous control of multiple devices.
Diagram illustrating 485 bus control connecting multiple power supply units for multi-machine control.
Figure 19: Low-Cost Communication Power Supply with 485 Bus Control.
Diagram showing network control options via Sinilink Cloud, PC host, mobile app, and router for remote management.
Figure 20: Network Control Anytime, Anywhere.

9 ഉപയോക്തൃ നുറുങ്ങുകൾ

  • കൃത്യമായ വോള്യത്തിന്tage and current settings, use the encoder for fine adjustments after selecting the digit with the SW button.
  • Utilize the data group function to save frequently used voltage and current settings for quick recall.
  • When charging batteries, always monitor the battery temperature and ensure the MPPT function is correctly configured for optimal solar charging efficiency.
  • If using the bare board independently, ensure proper insulation and mounting to prevent short circuits or damage.
  • Regularly check for firmware updates to access new features and improvements.

10. പ്രശ്‌നപരിഹാരം

  • പവർ/ഡിസ്‌പ്ലേ ഇല്ല: ഇൻപുട്ട് വോളിയം പരിശോധിക്കുകtage connections and ensure they are within the specified range (12.00V~140.0V). Verify polarity.
  • കൃത്യമല്ലാത്ത വായനകൾ: വോളിയം നടത്തുകtage and current calibration as described in Section 7. Ensure no load is connected during current zero calibration.
  • Output Not Stable: Check input power source stability. Ensure connections are secure. Verify that the load is not exceeding the power supply's capabilities.
  • Over-temperature Shutdown: Ensure the fan is not obstructed and is operating correctly. If an external temperature probe is connected, check its placement and functionality.
  • ആശയവിനിമയ പ്രശ്നങ്ങൾ: Verify baud rate settings (bRE) match the connected device. Check physical connections for serial or 485 communication. For WiFi, ensure the WF-POW module is correctly installed and configured.
  • ബാറ്ററി ചാർജിംഗ് പ്രശ്നങ്ങൾ: Check bCH (charging threshold) and bTF (cutoff current) settings. Ensure the power supply output voltage ബാറ്ററി വോള്യത്തേക്കാൾ കൂടുതലാണ്tage.

11. പരിപാലനം

  • വൃത്തിയാക്കൽ: ഉപകരണം വൃത്തിയായും പൊടിയില്ലാതെയും സൂക്ഷിക്കുക. വൃത്തിയാക്കാൻ മൃദുവായതും ഉണങ്ങിയതുമായ തുണി ഉപയോഗിക്കുക. ലിക്വിഡ് ക്ലീനറുകൾ ഉപയോഗിക്കരുത്.
  • വെൻ്റിലേഷൻ: Ensure adequate ventilation around the power supply to prevent overheating. Do not block the fan or air vents.
  • കണക്ഷനുകൾ: Periodically check all input and output connections for tightness and corrosion.
  • സംഭരണം: Store the device in a dry, cool environment when not in use.
  • ഫേംവെയർ അപ്‌ഡേറ്റുകൾ: നിർമ്മാതാവ് പരിശോധിക്കുക website for available firmware updates to ensure optimal performance and access to new features.

12. പാക്കേജ് ഉള്ളടക്കം

  • Package A:
    • Adjustable Power Supply (main module) x 1
    • Meter (control panel) x 1
    • കേബിളുകൾ x 2
  • പാക്കേജ് ബി:
    • Adjustable Power Supply (bare board, can be used independently) x 1

13. പിന്തുണ

For technical assistance, troubleshooting beyond this manual, or inquiries about accessories and parts, please contact your retailer or the manufacturer directly. Keep your purchase receipt for warranty purposes.

14. വീഡിയോ പ്രദർശനം

ഒരു ചെറിയ വിവരണത്തിനായി ഈ വീഡിയോ കാണുകview of the basic operations, including power on/off, setting voltage and current, and navigating display modes.

Video: Basic operation of the XY12522 power supply, demonstrating power control, voltage/current adjustment, and display cycling.

ഐഡിപെൻ XY12522 CNC DC ക്രമീകരിക്കാവുന്ന ബക്ക് പവർ സപ്ലൈ: പൂർണ്ണ പ്രവർത്തന ഗൈഡും ഫീച്ചർ ഡെമോയും

ഐഡിപെൻ XY12522 CNC DC ക്രമീകരിക്കാവുന്ന ബക്ക് പവർ സപ്ലൈ: പൂർണ്ണ പ്രവർത്തന ഗൈഡും ഫീച്ചർ ഡെമോയും

1:28 • 720×720 • നിർദ്ദേശങ്ങൾ

അനുബന്ധ രേഖകൾ - XY12522

പ്രീview ഐഡിപെൻ 1200W 20A DC-DC ബൂസ്റ്റ് കൺവെർട്ടർ മൊഡ്യൂൾ: സ്പെസിഫിക്കേഷനുകളും ഗൈഡും
ക്രമീകരിക്കാവുന്ന വോളിയമായ ഐഡിപെൻ 1200W 20A DC-DC ബൂസ്റ്റ് കൺവെർട്ടർ മൊഡ്യൂളിനായുള്ള വിശദമായ സ്പെസിഫിക്കേഷനുകൾ, ഉപയോഗ ഗൈഡ്, ട്രബിൾഷൂട്ടിംഗ്tag8-60V മുതൽ 12-83V വരെ പ്രവർത്തിക്കുന്ന e പവർ സപ്ലൈ മൊഡ്യൂൾ.
പ്രീview U-18 USB വോളിയംtagഇ, നിലവിലെ ടെസ്റ്റർ യൂസർ മാനുവൽ
Aideepen U-18 USB വോള്യത്തിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽtage, കറന്റ് ടെസ്റ്റർ എന്നിവ ഉൾപ്പെടുന്നു. വിശദമായ വിശകലനത്തിനായി അതിന്റെ സവിശേഷതകൾ, സുരക്ഷാ മുൻകരുതലുകൾ, ഇന്റർഫേസ് പ്രവർത്തനങ്ങൾ, സാങ്കേതിക സവിശേഷതകൾ, ഫാസ്റ്റ് ചാർജിംഗ് പ്രോട്ടോക്കോൾ പരിശോധന (QC, PD), PC സോഫ്റ്റ്‌വെയർ എന്നിവയെക്കുറിച്ച് അറിയുക.
പ്രീview Aideepen XY-BT13L/BT11L Battery Management Charge Discharge Controller User Manual
Detailed user manual for the Aideepen XY-BT13L/BT11L 10A/30A Battery Management, Charge, and Discharge Controller. Covers specifications, operation, system parameters, capacity correction, UPS mode, and MODBUS-RTU communication.
പ്രീview TS457 Voltagഇ ഇന്റേണൽ റെസിസ്റ്റൻസ് ടെസ്റ്റർ യൂസർ മാനുവൽ
Comprehensive user manual for the Aideepen TS457 Voltage Internal Resistance Tester. This guide details technical specifications, interface functions, power supply methods, testing procedures using Kelvin clamps and battery test stands, and various setting configurations for accurate DC voltage, ആന്തരിക പ്രതിരോധ അളവുകൾ.
പ്രീview Aideepen VTM100 ബാറ്ററി ഇൻഡിക്കേറ്റർ ഉപയോക്തൃ മാനുവൽ - വാല്യംtagഇ, എസ്ഒസി മോണിറ്ററിംഗ്
Aideepen VTM100 ബാറ്ററി ഇൻഡിക്കേറ്ററിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ. DC വോളിയം എങ്ങനെ നിരീക്ഷിക്കാമെന്ന് മനസിലാക്കുക.tagലെഡ്-ആസിഡ്, ടെർനറി ലിഥിയം, LiFePO4 തുടങ്ങിയ വിവിധ ബാറ്ററി കെമിസ്ട്രികൾക്കുള്ള e, ചാർജ്ജ് നില (SOC), താപനില.
പ്രീview Aideepen ESP32-CAM പ്രവർത്തന നിർദ്ദേശങ്ങളും സ്പെസിഫിക്കേഷനുകളും
വൈ-ഫൈയും ബ്ലൂടൂത്തും ഉള്ള വൈവിധ്യമാർന്ന ക്യാമറ മൊഡ്യൂളായ Aideepen ESP32-CAM പര്യവേക്ഷണം ചെയ്യുക. ഈ ഗൈഡിൽ ഉൽപ്പന്ന ആമുഖം, ഡ്യുവൽ-കോർ പ്രോസസ്സിംഗ്, PSRAM പോലുള്ള സവിശേഷതകൾ, പ്രകടന പാരാമീറ്ററുകൾ, RF സ്പെസിഫിക്കേഷനുകൾ, IoT ആപ്ലിക്കേഷനുകൾക്കും സ്മാർട്ട് ഉപകരണ വികസനത്തിനുമുള്ള പ്രാരംഭ ഉപയോഗ നിർദ്ദേശങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.