1. ആമുഖം
The Sekonic L-508 Zoom Master is a versatile external light meter designed for precise light measurement in various photographic conditions. It is built for all-weather use and offers comprehensive capabilities for both ambient and flash light readings, including mixed lighting scenarios. Its advanced features ensure accurate exposure control for professional and enthusiast photographers.
2 പ്രധാന സവിശേഷതകൾ
- Designed for all-weather use, ensuring reliability in diverse environments.
- Measures both reflected ambient and reflected flash, as well as mixed lighting, providing comprehensive exposure data.
- Features a 270-degree swivel head and a built-in retractable incident lumisphere for flexible measurement angles and incident light readings.
- Enables multiple flash cumulative measurement in either spot or incident mode, allowing accumulation of up to 9 flashes for complex lighting setups.
- Allows memorization of up to three readings in incident or spot mode for quick reference and comparison.
3. ഉൽപ്പന്ന ഘടകങ്ങൾ

ചിത്രം 3.1: മുൻഭാഗം View. This image displays the front of the Sekonic L-508 light meter, highlighting the main display screen, the ISO adjustment buttons, the Mode selection button, and the Power button. The incident lumisphere is visible at the top.

ചിത്രം 3.2: കോണാകൃതിയിലുള്ളത് View. This image provides an angled perspective of the light meter, showcasing the ergonomic design, the incident lumisphere in its extended position, and some of the side-mounted controls for operation.

ചിത്രം 3.3: വശം View. This image illustrates the side of the Sekonic L-508, featuring the zoom spot lens for reflected light measurements and the Memory button, which is used to store readings.

ചിത്രം 3.4: പിന്നിലേക്ക് View. This image shows the rear of the light meter, primarily displaying the battery compartment cover and other structural details.
4. സജ്ജീകരണം
- ബാറ്ററി ഇൻസ്റ്റാളേഷൻ: Locate the battery compartment on the back of the meter (refer to Figure 3.4). Open the cover and insert the required batteries, ensuring correct polarity. Close the compartment securely.
- പവർ ഓൺ: അമർത്തുക ശക്തി button to turn on the light meter. The display should illuminate.
- പ്രാരംഭ ക്രമീകരണങ്ങൾ: Set your desired ISO sensitivity using the ഐഎസ്ഒ buttons. This should match the ISO setting of your camera.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
5.1. Measuring Ambient Light
- സംഭവ പ്രകാശ അളവ്: Extend the incident lumisphere (white dome) by sliding it into position. Point the lumisphere towards the light source from the subject's position. Press the measurement button to obtain a reading.
- Reflected Light Measurement (Spot): Retract the incident lumisphere. Aim the spot meter's lens at the specific area of the subject you wish to measure. The L-508 offers a zoom spot feature for precise targeting. Press the measurement button.
5.2. Measuring Flash Light
- ഫ്ലാഷ് മോഡ്: അമർത്തുക മോഡ് button until the flash icon appears on the display.
- ഒറ്റ ഫ്ലാഷ്: Position the meter (incident or spot mode) and trigger your flash unit. The meter will display the f-stop.
- Multiple Flash Cumulative: In flash mode, after the first flash reading, trigger subsequent flashes. The meter can accumulate up to 9 flashes, providing a combined exposure value.
5.3. മെമ്മറി പ്രവർത്തനം
The L-508 allows you to store up to three readings. After taking a measurement, press the മെമ്മറി button (refer to Figure 3.3) to save the value. You can recall these values for comparison or averaging.
6. പരിപാലനം
- വൃത്തിയാക്കൽ: Use a soft, dry cloth to clean the meter's body. For the display and lens, use a lens cleaning cloth and solution if necessary, avoiding abrasive materials.
- സംഭരണം: ദീർഘനേരം ഉപയോഗിക്കാത്തപ്പോൾ, ചോർച്ച തടയാൻ ബാറ്ററികൾ നീക്കം ചെയ്യുക. മീറ്റർ തണുത്തതും വരണ്ടതുമായ സ്ഥലത്ത് സൂക്ഷിക്കുക, നേരിട്ടുള്ള സൂര്യപ്രകാശവും ഉയർന്ന താപനിലയും ഏൽക്കാത്ത സ്ഥലത്ത് സൂക്ഷിക്കുക.
- ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ: കൃത്യമായ റീഡിംഗുകൾ ഉറപ്പാക്കാൻ ഡിസ്പ്ലേയിൽ കുറഞ്ഞ ബാറ്ററി സൂചകം ദൃശ്യമാകുമ്പോൾ ബാറ്ററികൾ ഉടൻ മാറ്റിസ്ഥാപിക്കുക.
7. പ്രശ്നപരിഹാരം
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| മീറ്റർ പവർ ഓൺ ആകുന്നില്ല. | ഡെഡ് അല്ലെങ്കിൽ തെറ്റായി ഇൻസ്റ്റാൾ ചെയ്ത ബാറ്ററികൾ. | ബാറ്ററി പോളാരിറ്റി പരിശോധിക്കുക; ബാറ്ററികൾ മാറ്റിസ്ഥാപിക്കുക. |
| കൃത്യമല്ലാത്ത വായനകൾ. | Incorrect ISO setting; dirty lumisphere/lens; meter not calibrated. | Verify ISO setting; clean optical components; consult service center if calibration is suspected. |
| ഡിസ്പ്ലേ ശൂന്യമാണ് അല്ലെങ്കിൽ മിന്നിമറയുന്നു. | Low battery; extreme temperature. | Replace batteries; allow meter to acclimate to room temperature. |
8 സ്പെസിഫിക്കേഷനുകൾ
| മോഡൽ നമ്പർ | 401-508 |
| നിർമ്മാതാവ് | സെക്കോണിക് |
| ഇനത്തിൻ്റെ ഭാരം | 13.6 ഔൺസ് |
| പാക്കേജ് അളവുകൾ | 8.8 x 4.3 x 3.3 ഇഞ്ച് |
| ആദ്യം ലഭ്യമായ തീയതി | സെപ്റ്റംബർ 22, 2002 |
| അളക്കൽ മോഡുകൾ | Incident (with Lumisphere), Reflected (Spot) |
| ലൈറ്റ് തരങ്ങൾ | Ambient, Flash, Mixed Lighting |
| സ്വിവൽ ഹെഡ് | 270-ഡിഗ്രി |
| മെമ്മറി ഫംഗ്ഷൻ | 3 വായനകൾ വരെ |
| Flash Accumulation | 9 ഫ്ലാഷുകൾ വരെ |
9. വാറൻ്റിയും പിന്തുണയും