Apollo 1600-PK1

Apollo 1600 Dual Swing Gate Opener System User Manual

മോഡൽ: 1600-PK1

ബ്രാൻഡ്: അപ്പോളോ

1. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Apollo 1600 Dual Swing Gate Opener System is engineered for automating dual swing gates. This robust system is suitable for residential, farm, ranch, and light commercial applications. It is designed to operate gates up to 16 feet in length and 600 lbs per gate.

The system features a direct drive mechanism that attaches directly to the gate, utilizing a rust-proof linear, acme screw drive with self-lubricating gears. It offers versatility, allowing configuration for both push-to-open and pull-to-open applications.

2. പാക്കേജ് ഉള്ളടക്കം

This package (PKG 1) includes the following essential components:

  • Dual Swing Gate Operator (APL1600)
  • 1 1/2 Amp Battery Charger (APL404)
  • 2 Multi-Code Transmitters (MLT3089)
  • Receiver for Multi-Code Transmitters (MLTA1099)

Note: A 12-volt car-type battery is required for operation and is not supplied with this package. Apollo recommends a maintenance-free, deep cycle marine battery with a capacity of 105 amp/ മണിക്കൂർ.

Components of the Apollo 1600 Dual Swing Gate Opener system

This image displays the primary components of the Apollo 1600 Dual Swing Gate Opener system. Visible are the two linear actuators, which are the main mechanisms for moving the gates. Also shown is the control box, which houses the electronics, along with a battery charger and two remote control transmitters. Various mounting brackets and small hardware pieces are also included.

3 പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ

Read all instructions carefully before commencing installation and operation of the gate opener system. Failure to adhere to these instructions could lead to serious personal injury or significant property damage.

  • Ensure all local electrical codes and regulations are strictly followed during the installation process.
  • Always disconnect all power sources to the gate opener before performing any service, maintenance, or adjustments.
  • Maintain a safe distance for children and pets from the gate area, especially during gate operation.
  • Never permit children to operate the gate opener or play with the control devices.
  • Install appropriate warning signs on the gate to alert individuals of automatic operation.
  • Periodically inspect the gate and the opener system for any signs of wear, damage, or misalignment.

4. ഇൻസ്റ്റലേഷനും സജ്ജീകരണവും

4.1 പ്രീ-ഇൻസ്റ്റലേഷൻ ചെക്ക്‌ലിസ്റ്റ്

  • Verify that your gate's dimensions and weight are within the system's specified limits (maximum 16 feet in length and 600 lbs per gate).
  • Confirm that the gate swings freely and smoothly without any obstructions throughout its entire range of motion.
  • Ensure the availability of a suitable 12-volt deep cycle marine battery (not included) for power.
  • Gather all necessary tools and safety equipment required for the installation.

4.2. Mounting the Gate Operators

The direct drive system requires precise mounting of the operators directly to the gate and gate posts. Refer to the detailed instructions and diagrams provided in the comprehensive installation guide for specific mounting points, hardware usage, and alignment procedures. Proper alignment is critical for smooth and reliable operation.

4.3. ഇലക്ട്രിക്കൽ കണക്ഷനുകൾ

Connect the 1 1/2 Amp Battery Charger (APL404) to the 12-volt battery. Subsequently, connect the gate operators and the receiver (MLTA1099) to the main control board following the wiring diagram provided in the full manual. Ensure all electrical connections are secure, properly insulated, and protected from environmental elements.

4.4 ട്രാൻസ്മിറ്റർ പ്രോഗ്രാമിംഗ്

Program the Multi-Code Transmitters (MLT3089) to synchronize with the receiver (MLTA1099) by following the specific instructions included with the receiver unit. After programming, test each transmitter to confirm proper functionality and range.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1. മാനുവൽ പ്രവർത്തനം

ഒരു പവർ ഈ സാഹചര്യത്തിൽtage or system malfunction, the gate operators can be manually disengaged to allow for manual gate operation. Consult the specific instructions in your full manual for the correct procedure to disengage the actuator mechanism safely.

5.2. ഓട്ടോമാറ്റിക് ഓപ്പറേഷൻ

To operate the gate automatically, use one of the programmed Multi-Code Transmitters (MLT3089). Pressing the designated button once will activate the gate. The gate will automatically stop when it reaches its fully open or fully closed position.

5.3. Push-to-Open / Pull-to-Open Configuration

The Apollo 1600 system can be configured for either push-to-open or pull-to-open applications, depending on your gate's swing direction. This setting is typically adjusted during the initial setup of the control board and should be confirmed during installation.

6. പരിപാലനം

6.1. Regular Inspections

  • Annually inspect all mounting hardware, bolts, and fasteners for tightness and security.
  • Check the gate hinges and posts for any signs of wear, corrosion, or damage.
  • Ensure the gate moves freely and smoothly without any binding or excessive friction.

6.2. Actuator Care

The actuators are designed with self-lubricating gears. Periodically inspect the linear screw drive for any accumulation of dirt, debris, or foreign objects and clean as necessary. Avoid applying excessive lubricants unless specifically recommended by the manufacturer.

6.3. ബാറ്ററി പരിപാലനം

Regularly check the 12-volt deep cycle marine battery for its charge level and inspect the terminals for any signs of corrosion. Clean corroded terminals as needed and ensure the battery charger (APL404) is functioning correctly to maintain optimal battery health.

7. പ്രശ്‌നപരിഹാരം

7.1. Gate Not Responding to Transmitter

  • Check the battery level within the transmitter and replace if necessary.
  • Verify that the receiver (MLTA1099) is powered on and properly connected.
  • If issues persist, attempt to re-program the transmitter to the receiver.

7.2. Gate Not Opening/Closing Fully

  • Inspect the gate's path for any physical obstructions that may be impeding its movement.
  • Check the gate's free movement; hinges may require lubrication or adjustment.
  • Verify that the 12-volt battery is fully charged and supplying adequate power to the system.
  • Consult the full manual for instructions on adjusting limit switches, if applicable.

7.3. ഓപ്പറേഷൻ സമയത്ത് അസാധാരണമായ ശബ്ദങ്ങൾ

  • Inspect the actuators for any debris, damage, or signs of wear.
  • Check the gate hinges for wear or insufficient lubrication.
  • Ensure all mounting hardware for the gate and opener components is securely fastened.

8 സ്പെസിഫിക്കേഷനുകൾ

  • മോഡൽ: Apollo 1600 Dual Swing Gate Opener (APL1600)
  • ഭാഗം നമ്പർ: 1600-PK1
  • ബ്രാൻഡ്: അപ്പോളോ
  • പരമാവധി ഗേറ്റ് നീളം: Up to 16 feet per gate
  • പരമാവധി ഗേറ്റ് ഭാരം: Up to 600 lbs per gate
  • ആക്യുവേറ്റർ തരം: Rust-proof linear, acme screw drive, self-lubricating gears
  • ശുപാർശ ചെയ്യുന്ന ആപ്ലിക്കേഷനുകൾ: Residential, Farm and Ranch, Light Commercial
  • വൈദ്യുതി ആവശ്യകത: 12 Volts DC (requires 12V deep cycle marine battery, 105 amp/hour, not supplied)
  • ഉൾപ്പെടുത്തിയ ചാർജർ: 1 1/2 Amp Battery Charger (APL404)
  • Included Transmitters: 2 Multi-Code Transmitters (MLT3089)
  • Included Receiver: Multi-Code Transmitters Receiver (MLTA1099)
  • ആദ്യം ലഭ്യമായ തീയതി: ഡിസംബർ 13, 2006

9. വാറൻ്റിയും പിന്തുണയും

For detailed warranty information, technical assistance, and customer support, please refer to the specific documentation included with your Apollo 1600 Dual Swing Gate Opener System. Alternatively, you may visit the official Apollo website for further resources.

നിർമ്മാതാവ്: അപ്പോളോ