This manual provides essential information for the safe and effective use of the OSRAM Sylvania 54507 HP600 Projector Light Bulb. This bulb is a 575-watt, 115-volt halogen lamp featuring a G9.5 Medium Bipin base and a T6 shape. It has a rated life of 300 hours, a color temperature of 3250K, and a C-13D filament with a clear finish.

Image: The OSRAM Sylvania 54507 HP600 Projector Light Bulb, showcasing its T6 shape and G9.5 base.
സജ്ജീകരണ നിർദ്ദേശങ്ങൾ
Proper installation is crucial for the performance and longevity of your projector bulb. Always ensure the projector is powered off and unplugged before beginning installation.
- സുരക്ഷ ആദ്യം: Turn off the projector and unplug it from the power source. Allow the projector and the old bulb to cool down completely before handling. Hot bulbs can cause severe burns.
- Locate Bulb Compartment: Refer to your projector's specific user manual to locate and open the lamp compartment. This usually involves removing a cover secured by screws.
- പഴയ ബൾബ് നീക്കം ചെയ്യുക: Carefully disconnect any wiring and unfasten the old bulb assembly. Handle the old bulb with care, as it may be fragile.
- പുതിയ ബൾബ് സ്ഥാപിക്കുക: Gently insert the new OSRAM Sylvania 54507 HP600 bulb into the projector's lamp ഭവന. ബൾബിന്റെ ഗ്ലാസ് ഭാഗത്ത് നഗ്നമായ കൈകൾ കൊണ്ട് തൊടുന്നത് ഒഴിവാക്കുക. Oils from your skin can create hot spots, leading to premature bulb failure. Use a clean cloth or gloves if necessary. Ensure the G9.5 bipin base pins align correctly with the socket.
- Secure Bulb and Compartment: Fasten the bulb assembly securely and close the lamp compartment cover. Ensure all screws are tightened to prevent dust ingress and ensure proper cooling.
- പവർ ഓൺ: Plug the projector back into the power source and turn it on. The new bulb should illuminate.

Image: Diagram illustrating the dimensions of the G9.5 bipin base, showing pin spacing and overall base measurements for compatibility reference.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed, the OSRAM Sylvania 54507 HP600 bulb operates as part of your projector system. Follow these general guidelines for optimal performance:
- പവർ സൈക്കിൾ: Turn on the projector using its power button. Allow the bulb to warm up to full brightness, which may take a few moments.
- കൂൾ-ഡൗൺ കാലയളവ്: After use, turn off the projector and allow it to complete its internal cool-down cycle before unplugging or moving it. This protects the bulb from thermal shock and extends its lifespan.
- ഇടയ്ക്കിടെ ഓൺ/ഓഫ് ചെയ്യുന്നത് ഒഴിവാക്കുക: Minimize turning the projector on and off rapidly, as this can reduce the bulb's rated life.
മെയിൻ്റനൻസ്
Regular maintenance of your projector system helps ensure the longevity and performance of the OSRAM Sylvania 54507 HP600 bulb.
- Projector Filter Cleaning: Periodically clean or replace your projector's air filters as recommended by the projector manufacturer. Clogged filters can lead to overheating, which significantly shortens bulb life.
- ബൾബ് മാറ്റിസ്ഥാപിക്കൽ: The OSRAM Sylvania 54507 HP600 has a rated life of 300 hours. Monitor your projector's lamp hour counter and replace the bulb when it approaches its end-of-life or when brightness noticeably diminishes.
- സംഭരണം: If storing a spare bulb, keep it in its original packaging in a cool, dry place away from direct sunlight and extreme temperatures.
ട്രബിൾഷൂട്ടിംഗ്
If you encounter issues with your projector bulb, consider the following common problems and solutions:
- ബൾബ് കത്തുന്നില്ല:
- പവർ പരിശോധിക്കുക: Ensure the projector is properly plugged in and receiving power.
- വീണ്ടും ഇൻസ്റ്റാൾ ചെയ്യൽ: Power off and unplug the projector. Re-open the lamp compartment and ensure the bulb is seated correctly and all connections are secure.
- ജീവിതാവസാനം: If the bulb has reached or exceeded its rated life (300 hours), it may have failed. Replace with a new bulb.
- Projector Error: Consult your projector's manual for specific error codes related to lamp പരാജയം.
- മങ്ങിയ അല്ലെങ്കിൽ മിന്നുന്ന പ്രകാശം:
- Bulb Nearing End of Life: Dimness or flickering often indicates the bulb is nearing the end of its operational lifespan.
- അമിത ചൂടാക്കൽ: Ensure projector vents are clear and filters are clean to prevent overheating.
If these steps do not resolve the issue, contact customer support or a qualified technician.
ഉൽപ്പന്ന സവിശേഷതകൾ
Key technical specifications for the OSRAM Sylvania 54507 HP600 Projector Light Bulb:
| സ്പെസിഫിക്കേഷൻ | വിശദാംശങ്ങൾ |
|---|---|
| ബ്രാൻഡ് | ഓഫിസിലേക്ക് |
| മോഡൽ നമ്പർ | 54507 (HP600) |
| ലൈറ്റ് തരം | ഹാലൊജെൻ |
| വാട്ട്tage | 575 വാട്ട്സ് |
| വാല്യംtage | 115 വോൾട്ട് |
| ബൾബ് ബേസ് | G9.5 Medium Bipin |
| ബൾബ് ആകൃതി വലിപ്പം | T6 |
| റേറ്റുചെയ്ത ജീവിതം | 300 മണിക്കൂർ |
| വർണ്ണ താപനില | 3250 കെൽവിൻ |
| ഫിലമെന്റ് തരം | സി -13 ഡി |
| പൂർത്തിയാക്കുക | ക്ലിയർ |
| മെറ്റീരിയൽ | ചെമ്പ് |
| ഇനത്തിൻ്റെ ഭാരം | 0.81 ഔൺസ് |
വാറൻ്റി വിവരങ്ങൾ
Specific warranty terms for the OSRAM Sylvania 54507 HP600 Projector Light Bulb are typically provided by the manufacturer, OSRAM, or the authorized seller at the time of purchase. Please retain your proof of purchase for any warranty claims. For detailed warranty information, refer to the documentation included with your purchase or visit the official OSRAM webസൈറ്റ്.
ഉപഭോക്തൃ പിന്തുണ
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact OSRAM customer support or the retailer from whom you purchased the bulb.
- OSRAM Store: കൂടുതൽ വിവരങ്ങളും ബന്ധപ്പെടാനുള്ള വിശദാംശങ്ങളും ഔദ്യോഗിക വെബ്സൈറ്റിൽ ലഭ്യമാണ്. OSRAM Store on Amazon.
- വിൽപ്പനക്കാരുടെ പിന്തുണ: Contact the seller directly for purchase-specific support.