White-Rodgers 36E38-301

White Rodgers 36E38-301 Gas Valve Instruction Manual

Model: 36E38-301 | Brand: White-Rodgers

ആമുഖം

This manual provides detailed instructions for the safe installation, operation, and maintenance of the White Rodgers 36E38-301 Gas Valve. This valve is specifically designed for natural gas applications only and operates on a 24 VAC power supply. It features a redundant (pilot) valve design with specified outlet pressures for optimal performance in compatible heating systems.

പ്രധാനപ്പെട്ട സുരക്ഷാ നിർദ്ദേശങ്ങൾ

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read these instructions thoroughly before installing or servicing this equipment.

ഉൽപ്പന്ന സവിശേഷതകൾ

White Rodgers 36E38-301 Gas Valve
Image: White Rodgers 36E38-301 Gas Valve. This image displays the compact design of the gas valve, showing its various ports and solenoid components. The main body is metallic, with blue and black plastic components for control, indicating its robust construction.

സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Note: Installation should only be performed by a qualified technician.

  1. പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധന:
    • Verify that the gas valve model (36E38-301) matches the system requirements for natural gas and 24 VAC.
    • Ensure the gas supply is turned off at the main valve.
    • ഉപകരണത്തിലേക്കുള്ള വൈദ്യുതി ബന്ധം വിച്ഛേദിക്കുക.
  2. മൗണ്ടിംഗ്:
    • Mount the valve securely in the correct orientation as specified by the appliance manufacturer.
    • Ensure adequate clearance for wiring and gas piping.
  3. ഗ്യാസ് പൈപ്പിംഗ് കണക്ഷനുകൾ:
    • Apply pipe sealant suitable for natural gas to all male pipe threads. Do not apply sealant to the first two threads.
    • Connect the gas supply line to the inlet port (1/2").
    • Connect the appliance manifold to the outlet port (3/4").
    • Tighten all connections firmly but do not overtighten.
  4. ഇലക്ട്രിക്കൽ വയറിംഗ്:
    • Connect the 24 VAC power supply wires to the appropriate terminals on the valve as per the appliance wiring diagram.
    • എല്ലാ കണക്ഷനുകളും സുരക്ഷിതവും ഇൻസുലേറ്റ് ചെയ്തതുമാണെന്ന് ഉറപ്പാക്കുക.
  5. ചോർച്ച പരിശോധന:
    • പ്രധാന ഗ്യാസ് വിതരണം ഓണാക്കുക.
    • Apply a non-corrosive leak detection solution to all gas connections.
    • Bubbles indicate a leak. Tighten connections or reapply sealant as necessary.
    • വാതക ചോർച്ച പരിശോധിക്കാൻ ഒരിക്കലും തുറന്ന തീജ്വാല ഉപയോഗിക്കരുത്.
  6. പ്രാരംഭ ആരംഭം:
    • Restore electrical power to the appliance.
    • പ്രാരംഭ സ്റ്റാർട്ടപ്പിനും പൈലറ്റ് ലൈറ്റിംഗ് നടപടിക്രമങ്ങൾക്കും ഉപകരണ നിർമ്മാതാവിന്റെ നിർദ്ദേശങ്ങൾ പാലിക്കുക.

No relevant official product videos for installation from a 'Seller' were found in the provided data.

പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The White Rodgers 36E38-301 Gas Valve operates in conjunction with your appliance's control system. It is designed to regulate the flow of natural gas to the burner based on demand.

  1. സാധാരണ പ്രവർത്തനം: When the appliance's control system calls for heat, it sends a 24 VAC signal to the gas valve.
  2. Pilot Ignition: The redundant pilot valve opens first, allowing gas to flow to the pilot burner for ignition.
  3. Main Burner Ignition: Once the pilot is established and sensed by the control system, the main valve opens, allowing gas to flow to the main burner for heating.
  4. ഷട്ട് ഡൗൺ: When the heat demand is satisfied, the 24 VAC signal is removed, and the gas valve closes, shutting off the gas supply to both the pilot and main burners.

Important: Do not attempt to manually operate the valve unless specifically instructed by a qualified technician during troubleshooting or service procedures.

No relevant official product videos for operation from a 'Seller' were found in the provided data.

മെയിൻ്റനൻസ് മാർഗ്ഗനിർദ്ദേശങ്ങൾ

The White Rodgers 36E38-301 Gas Valve is designed for reliable operation with minimal maintenance. However, periodic checks are recommended to ensure continued safe and efficient performance.

Caution: Do not attempt to disassemble or repair the gas valve. If the valve is found to be faulty, it must be replaced by a qualified technician.

No relevant official product videos for maintenance from a 'Seller' were found in the provided data.

പൊതുവായ പ്രശ്‌നങ്ങൾ പരിഹരിക്കുന്നു

This section provides guidance for common issues. For complex problems or if you are unsure, always contact a qualified service technician.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ബർണറിലേക്ക് വാതക പ്രവാഹമില്ലGas supply off; Electrical power off; Faulty thermostat/control; Faulty gas valveCheck main gas supply; Check electrical breaker/fuse; Verify thermostat setting; Contact technician for valve inspection or replacement.
പൈലറ്റ് ലൈറ്റ് പ്രകാശിക്കില്ലDirty pilot orifice; Faulty thermocouple/thermopile; Low gas pressureClean pilot orifice; Replace thermocouple/thermopile; Contact gas supplier or technician for pressure check.
വാതക ഗന്ധം കണ്ടെത്തിവാതക ചോർച്ചImmediately turn off gas supply and ventilate area. Do not operate electrical switches or create sparks. Contact your gas company and a qualified technician immediately.

ഉൽപ്പന്ന സവിശേഷതകൾ

കുറിപ്പ്: അറിയിപ്പുകൾ കൂടാതെ സവിശേഷതകൾ മാറ്റത്തിന് വിധേയമാണ്.

വാറന്റി വിവരങ്ങളും സാങ്കേതിക പിന്തുണയും

Specific warranty details for the White Rodgers 36E38-301 Gas Valve are typically provided with the product packaging or can be obtained directly from the manufacturer or an authorized distributor.

For technical support, service, or warranty claims, please contact White-Rodgers customer service or an authorized service center.

നിർമ്മാതാവിനെ ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾ:

Please refer to the product packaging or the manufacturer's webഏറ്റവും പുതിയ കോൺടാക്റ്റ് വിശദാംശങ്ങൾക്കും പിന്തുണാ ഉറവിടങ്ങൾക്കുമുള്ള സൈറ്റ്.

No relevant official product videos for warranty or support from a 'Seller' were found in the provided data.

അനുബന്ധ രേഖകൾ - 36E38-301

പ്രീview Installation Instructions for White Rodgers 36G/J Series Combination Gas Valves
Comprehensive installation, operation, and safety instructions for White Rodgers 36G22, 36G23, 36G24, 36G52, 36J22, 36J23, 36J24, and 36J52 single-stage combination gas valves used in DSI and HSI systems.
പ്രീview White-Rodgers F92-1021 Modulated Gas Conversion Kit Installation Instructions
Installation instructions for the White-Rodgers F92-1021 modulated natural gas to L.P. gas conversion kit, compatible with 36J27/36H27 series gas valves. Includes safety warnings, conversion steps, and pressure adjustment procedures.
പ്രീview White-Rodgers 791P-751KT1 Premium Pilot Burner Assembly for Carrier/ICP Systems
Comprehensive guide to the White-Rodgers 791P-751KT1 Premium Pilot Burner Assembly, a Carrier OEM qualified replacement part. Covers product overview, features, technical specifications, installation instructions, and troubleshooting for HVAC technicians.
പ്രീview White-Rodgers 50A22-201 Pilot Relight/Timer Control Installation Instructions
Installation instructions for the White-Rodgers 50A22-201 Pilot Relight/Timer Control, detailing its description, specifications, safety precautions, and wiring diagrams for HVAC systems.
പ്രീview White-Rodgers 36C/36D Series HSI/DSI Proven Pilot Gas Valves Installation Guide
Installation instructions, safety precautions, specifications, wiring diagrams, and parts for White-Rodgers 36C/36D series HSI and DSI proven pilot gas valves. Covers universal electronic ignition gas valves for various heating systems.
പ്രീview White-Rodgers 36G Universal Gas Valves Field Conversion Instructions
Field conversion instructions for White-Rodgers 36G universal gas valves, covering LP gas conversion and non-piloted applications. Includes model details, wiring diagrams, and safety warnings.