1. ആമുഖം
The ESI 597IR Kit is a comprehensive diagnostic tool designed for automotive and electrical professionals. It combines a CAT III 1000V rated Digital Multimeter (DMM) with an EST-100 Infrared (IR) Thermometer and an inductive RPM pick-up. This kit is engineered for precision, safety, and durability, featuring a waterproof design to IP67 standards. It is ideal for measuring voltage, current, resistance, temperature, and engine RPM, providing essential data for vehicle diagnostics and electrical system analysis.
2 സുരക്ഷാ വിവരങ്ങൾ
WARNING: Read and understand all safety instructions before operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- പ്രാദേശികവും ദേശീയവുമായ സുരക്ഷാ കോഡുകൾ എല്ലായ്പ്പോഴും പാലിക്കുക.
- ഉപകരണം കേടായതായി തോന്നുകയോ ടെസ്റ്റ് ലീഡുകൾ തകരാറിലാവുകയോ ചെയ്താൽ അത് ഉപയോഗിക്കരുത്.
- Ensure the device is rated for the voltage and current levels being measured (CAT III 1000V).
- സുരക്ഷാ ഗ്ലാസുകളും ഇൻസുലേറ്റഡ് കയ്യുറകളും ഉൾപ്പെടെ ഉചിതമായ വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ (പിപിഇ) ധരിക്കുക.
- Avoid contact with live circuits. Always assume circuits are live until verified otherwise.
- സ്ഫോടനാത്മകമായ അന്തരീക്ഷത്തിലോ കത്തുന്ന വസ്തുക്കളുടെ സമീപത്തോ ഉപകരണം പ്രവർത്തിപ്പിക്കരുത്.
- Keep the device dry. Although waterproof to IP67, prolonged submersion is not recommended.
- നിർദ്ദിഷ്ട ബാറ്ററി തരം മാത്രം ഉപയോഗിക്കുക, ഇൻസ്റ്റാളേഷൻ സമയത്ത് ശരിയായ പോളാരിറ്റി ഉറപ്പാക്കുക.
3. ഉൾപ്പെടുത്തിയിരിക്കുന്ന ഘടകങ്ങൾ
The ESI 597IR Kit comes complete with the following components:
- ESI 597IR Digital Multimeter
- EST-100 Infrared Thermometer Adapter
- ടെസ്റ്റ് ലീഡുകൾ (ചുവപ്പും കറുപ്പും)
- Inductive RPM Pick-up
- താപനില അന്വേഷണം
- 9-വോൾട്ട് ബാറ്ററി
- ഹാർഡ് സ്റ്റോറേജ് കേസ്
- നിർദ്ദേശ മാനുവൽ (ഈ പ്രമാണം)

ചിത്രം 3.1: ഓവർview of all components included in the ESI 597IR Kit.
4. സജ്ജീകരണം
4.1 ബാറ്ററി ഇൻസ്റ്റാളേഷൻ
- Locate the battery compartment cover on the rear of the ESI 597IR DMM.
- കവർ ഉറപ്പിക്കുന്ന സ്ക്രൂ നീക്കം ചെയ്യാൻ ഒരു സ്ക്രൂഡ്രൈവർ ഉപയോഗിക്കുക.
- Insert the supplied 9-volt battery, ensuring correct polarity (+ and -).
- ബാറ്ററി കമ്പാർട്ട്മെന്റ് കവർ മാറ്റി സ്ക്രൂ ഉപയോഗിച്ച് സുരക്ഷിതമാക്കുക.
4.2 ടെസ്റ്റ് ലീഡുകൾ ബന്ധിപ്പിക്കുന്നു
Insert the red test lead into the VΩmA input jack and the black test lead into the COM input jack on the DMM. Ensure a secure connection.
4.3 Connecting EST-100 IR Thermometer Adapter
The EST-100 IR Thermometer adapter connects to the DMM using its integrated leads. Plug the red lead into the VΩmA input and the black lead into the COM input. The DMM will then display temperature readings from the EST-100.
4.4 Connecting Inductive RPM Pick-up
Connect the inductive RPM pick-up to the designated RPM input on the DMM. The pick-up features a five-position adjustable sensitivity switch to optimize signal detection for various ignition systems.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
5.1 Digital Multimeter (DMM) Functions
The ESI 597IR DMM offers a wide range of measurement capabilities. Use the rotary dial to select the desired function.
- വാല്യംtage Measurement (DCV/ACV): അനുയോജ്യമായ വോളിയം തിരഞ്ഞെടുക്കുകtage range. Connect test leads in parallel with the circuit or component. The DMM is rated for CAT III 1000V.
- Current Measurement (DCA/ACA): Select the appropriate current range (up to 20A fused). Connect the DMM in series with the circuit. Ensure the circuit is de-energized before connecting.
- പ്രതിരോധം (Ω): Select the resistance range. Ensure the circuit is de-energized before measuring. Connect test leads across the component.
- തുടർച്ച: Select the continuity function. The DMM will emit an audible tone if continuity is detected.
- ഡയോഡ് ടെസ്റ്റ്: Select the diode test function. Connect test leads across the diode to measure forward voltagഇ ഡ്രോപ്പ്.
- ഫ്രീക്വൻസി/ഡ്യൂട്ടി സൈക്കിൾ: Used for measuring signal frequency and duty cycle in various automotive sensors and circuits.
- Peak Min/Max Function: This function captures transient voltages as fast as 1 millisecond, useful for diagnosing intermittent electrical issues. Activate by pressing the 'PEAK' button.
- മിസ് പൾസ് വീതി: Specifically designed for measuring fuel injector on-time, providing critical data for engine performance analysis.
5.2 EST-100 IR Thermometer Operation
Once connected to the DMM, the EST-100 allows for non-contact temperature measurement. Point the IR thermometer at the target surface. The DMM will display the temperature reading. The EST-100 has an 8:1 distance-to-spot ratio, meaning at 8 inches from the target, it measures a 1-inch diameter area. It can measure temperatures up to 1022°F (550°C).
5.3 Inductive RPM Pick-up Operation
Attach the inductive RPM pick-up to an ignition wire or other suitable location to detect engine RPM. Adjust the five-position sensitivity switch on the pick-up to ensure accurate readings for different engine types and ignition systems. The DMM will display the engine revolutions per minute.
6. പരിപാലനം
6.1 വൃത്തിയാക്കൽ
To clean the device, wipe the exterior with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all circuits before cleaning.
6.2 ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ
When the low battery indicator appears on the DMM display, replace the 9-volt battery as described in Section 4.1. Always use a fresh alkaline 9-volt battery.
6.3 സംഭരണം
Store the ESI 597IR Kit in its hard storage case when not in use. This protects the instruments and accessories from dust, moisture, and physical damage. Store in a cool, dry place away from direct sunlight and extreme temperatures.

Figure 6.1: The ESI 597IR Kit stored in its hard case.

Figure 6.2: The exterior of the hard storage case.
7. പ്രശ്നപരിഹാരം
- ഡിസ്പ്ലേ/പവർ ഇല്ല:
- Check battery installation and ensure it is a fresh 9-volt battery.
- Verify the rotary switch is turned to an ON position.
- തെറ്റായ വായനകൾ:
- Ensure test leads are fully inserted and not damaged.
- Verify the correct function and range are selected on the DMM.
- For IR thermometer, ensure the target is within the specified distance-to-spot ratio.
- For RPM pick-up, adjust the sensitivity switch.
- Fuses Blown (for current measurements):
- If the DMM does not read current, the internal fuse may be blown. Refer to the DMM's internal diagram for fuse replacement. Always replace with a fuse of the same type and rating (e.g., 20A fused range).
- ഇടയ്ക്കിടെയുള്ള വായനകൾ:
- Check for loose connections at the DMM jacks or on the components being tested.
- Ensure the test environment is stable and free from excessive electrical noise.
8 സ്പെസിഫിക്കേഷനുകൾ
| സ്പെസിഫിക്കേഷൻ | മൂല്യം |
|---|---|
| മോഡൽ | 597IR |
| സുരക്ഷാ റേറ്റിംഗ് | ക്യാറ്റ് III 1000 വി |
| വാട്ടർപ്രൂഫ് റേറ്റിംഗ് | IP67 |
| IR Thermometer Model | EST-100 |
| IR Temp Range | 1022°F (550°C) വരെ |
| IR Distance Ratio | 8:1 |
| Peak Min/Max Capture | 1 മില്ലിസെക്കൻഡ് |
| നിലവിലെ ശ്രേണി | 20 Amperes (fused) |
| പവർ ഉറവിടം | 9-വോൾട്ട് ബാറ്ററി |
| ഇനത്തിൻ്റെ ഭാരം | 5.1 പൗണ്ട് |
| നിർമ്മാതാവ് | ഇലക്ട്രോണിക് സ്പെഷ്യാലിറ്റികൾ |
| യു.പി.സി | 855174001427 |
9. വാറൻ്റി വിവരങ്ങൾ
This product is covered by a manufacturer's warranty. For specific details regarding warranty coverage, duration, and terms, please refer to the warranty card included with your purchase or contact the manufacturer directly. Keep your proof of purchase for warranty claims.
10. ഉപഭോക്തൃ പിന്തുണ
For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Electronic Specialties customer support. Contact information can typically be found on the manufacturer's official webസൈറ്റ് അല്ലെങ്കിൽ ഉൽപ്പന്ന പാക്കേജിംഗിൽ.