Cisco WS-C2975GS-48PS-L

Cisco Catalyst 2975 48-Port LAN Base Switch

Model: WS-C2975GS-48PS-L

ആമുഖം

This manual provides essential instructions for the installation, operation, maintenance, and troubleshooting of the Cisco Catalyst 2975 48-Port LAN Base Switch (Model: WS-C2975GS-48PS-L). This device is designed to provide enhanced LAN services for commercial branch office networks, offering Gigabit Ethernet and Power over Ethernet (PoE) connectivity.

ഉൽപ്പന്നം കഴിഞ്ഞുview

The Cisco Catalyst 2975 LAN Base Switch is a fixed-configuration, stackable intelligent Ethernet switch. It features 48 ports with Gigabit Ethernet and Power over Ethernet (PoE) capabilities, enabling efficient network connectivity and power delivery to compatible devices. Key features include high-speed stacking for up to nine switches and unified stack management for simplified network administration.

ഫ്രണ്ട് view of the Cisco Catalyst 2975 48-Port LAN Base switch, showing 48 Ethernet ports and status LEDs.

This image displays the front panel of the Cisco Catalyst 2975 switch. It features 48 RJ-45 Ethernet ports, arranged in groups, along with status indicator LEDs above each port group. On the far right, there are four additional uplink ports, likely SFP or Gigabit Ethernet, and more status indicators. The overall design is a standard rack-mountable network switch.

സജ്ജമാക്കുക

  1. അൺപാക്കിംഗും പരിശോധനയും: Carefully remove the switch from its packaging. Inspect the device for any signs of physical damage. Report any damage to your supplier immediately. Ensure all components listed in the packing list are present.
  2. മൗണ്ടിംഗ്: The switch can be installed in a standard 19-inch equipment rack or placed on a desktop.
    • റാക്ക് മൗണ്ടിംഗ്: Attach the provided rack-mount brackets to the sides of the switch using the supplied screws. Secure the switch into the rack using appropriate rack screws.
    • ഡെസ്ക്ടോപ്പ് പ്ലേസ്മെന്റ്: Ensure the surface is flat, stable, and allows for adequate ventilation around the switch. Attach the rubber feet to the bottom of the switch if not already present.
  3. ബന്ധിപ്പിക്കുന്ന പവർ: Connect the power cord to the AC power connector on the rear of the switch and then to a grounded AC power outlet. The switch will power on automatically.
  4. Connecting Network Cables: Connect Ethernet cables from your network devices (computers, servers, access points) to the RJ-45 ports on the front panel. For devices requiring Power over Ethernet (PoE), ensure they are connected to PoE-enabled ports. Use appropriate Gigabit Ethernet cables (Category 5e or higher) for optimal performance.
  5. പ്രാരംഭ കോൺഫിഗറേഷൻ ആക്സസ്: For initial configuration, connect a console cable (RJ-45 to DB-9) from your management workstation to the console port on the switch. Use a terminal emulation program (e.g., PuTTY, Tera Term) with settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.

പ്രവർത്തിക്കുന്നു

  • LED സൂചകങ്ങൾ: Observe the front panel LEDs to monitor switch status, port activity, and PoE status. Refer to the detailed LED status guide in the full product documentation for specific interpretations.
  • സ്റ്റാക്കിംഗ്: The Catalyst 2975 supports high-speed stacking. Connect multiple switches using dedicated stacking cables to form a single logical unit, simplifying management and increasing port density. Follow the stacking guide for proper cable connections and configuration.
  • പവർ ഓവർ ഇഥർനെറ്റ് (PoE): PoE ports automatically detect and provide power to compatible PoE-enabled devices (e.g., IP phones, wireless access points, IP cameras) connected via Ethernet cables. Ensure the total power budget is not exceeded.
  • മാനേജ്മെൻ്റ്: The switch can be managed via a Command Line Interface (CLI) accessible through the console port or Telnet/SSH, or through a web-based graphical user interface (GUI) if enabled. Refer to the Cisco IOS Software Configuration Guide for detailed management instructions.

മെയിൻ്റനൻസ്

  • വൃത്തിയാക്കൽ: Keep the switch clean and free of dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners directly on the switch. Ensure ventilation openings are clear of obstructions.
  • ഫേംവെയർ അപ്‌ഡേറ്റുകൾ: ഇടയ്ക്കിടെ സിസ്കോ പിന്തുണ പരിശോധിക്കുക website for available firmware updates. Applying updates can improve performance, add features, and address security vulnerabilities. Follow the provided instructions carefully when performing firmware upgrades.
  • പാരിസ്ഥിതിക പരിഗണനകൾ: Operate the switch within its specified temperature and humidity ranges. Ensure proper airflow to prevent overheating. Avoid exposing the switch to direct sunlight, excessive moisture, or extreme temperatures.

ട്രബിൾഷൂട്ടിംഗ്

  • ശക്തിയില്ല: If the switch does not power on, verify the power cord is securely connected to both the switch and a working power outlet. Check the power source and any circuit breakers.
  • ലിങ്ക്/കണക്റ്റിവിറ്റി ഇല്ല: If a device is not connecting, check the Ethernet cable for damage and ensure it is properly seated in both the switch port and the device. Verify the link status LED on the switch port. Try a different port or cable.
  • PoE Issues: If a PoE device is not receiving power, ensure it is connected to a PoE-enabled port. Check the PoE status LED for the port. Verify the switch's total PoE power budget is not exceeded.
  • മന്ദഗതിയിലുള്ള നെറ്റ്‌വർക്ക് പ്രകടനം: Check for excessive network traffic, duplex mismatches, or faulty cables. Ensure all devices are operating at their intended speeds (e.g., Gigabit Ethernet).
  • ഫാക്ടറി പുന et സജ്ജമാക്കുക: In case of severe configuration issues, a factory reset may be performed. Refer to the Cisco documentation for the specific procedure, as this will erase all configurations.

സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
മോഡൽ നമ്പർWS-C2975GS-48PS-L
ബ്രാൻഡ്സിസ്കോ
നിർമ്മാതാവ്സിസ്കോ
തുറമുഖങ്ങളുടെ എണ്ണം48 (Gigabit Ethernet) + Uplinks
ഇൻ്റർഫേസ് തരംPoE (പവർ ഓവർ ഇഥർനെറ്റ്)
ഡാറ്റ കൈമാറ്റ നിരക്ക്10 Gigabits Per Second (Uplinks)
ഉൽപ്പന്ന അളവുകൾ18 x 16 x 2 ഇഞ്ച്
ഇനത്തിൻ്റെ ഭാരം16 പൗണ്ട്
യു.പി.സി882658249273

വാറൻ്റിയും പിന്തുണയും

This Cisco product is covered by a manufacturer's warranty. For detailed warranty information, including terms and conditions, please refer to the official Cisco website or the documentation included with your purchase. For technical support, software downloads, and additional resources, visit the Cisco Support Community or contact Cisco technical assistance. Keep your product serial number readily available when seeking support.

ഓൺലൈൻ ഉറവിടങ്ങൾ: For the most up-to-date documentation, software, and support tools, please visit the official Cisco webസൈറ്റ്: www.cisco.com/c/en/us/support/

അനുബന്ധ രേഖകൾ - WS-C2975GS-48PS-L

പ്രീview സിസ്കോ കാറ്റലിസ്റ്റ് 3560-CX, 2960-CX സീരീസ് സ്വിച്ചുകൾ: സവിശേഷതകൾ, സ്പെസിഫിക്കേഷനുകൾ, പതിവുചോദ്യങ്ങൾ
സിസ്കോ കാറ്റലിസ്റ്റ് 3560-CX, 2960-CX സീരീസ് കോംപാക്റ്റ് നെറ്റ്‌വർക്ക് സ്വിച്ചുകൾക്കായുള്ള സവിശേഷതകൾ, സ്പെസിഫിക്കേഷനുകൾ, താരതമ്യങ്ങൾ, മൗണ്ടിംഗ്, ഹാർഡ്‌വെയർ, സോഫ്റ്റ്‌വെയർ, സുരക്ഷ, പവർ, ഊർജ്ജ കാര്യക്ഷമത, വാറന്റി വിവരങ്ങൾ എന്നിവ വിശദീകരിക്കുന്ന ഒരു സമഗ്രമായ FAQ ഡോക്യുമെന്റ്.
പ്രീview സിസ്കോ കാറ്റലിസ്റ്റ് 3850 സീരീസ് സ്വിച്ചുകൾ: ഉൽപ്പന്നം അവസാനിച്ചുview കൂടാതെ സ്പെസിഫിക്കേഷനുകളും
ഒരു സമഗ്രമായ ഓവർview സിസ്കോ കാറ്റലിസ്റ്റ് 3850 സീരീസ് സ്വിച്ചുകളുടെ ഒരു ശ്രേണി, ഉൽപ്പന്ന സവിശേഷതകൾ, സ്വിച്ച് മോഡലുകൾ, ഫ്രണ്ട്, റിയർ പാനൽ ഘടകങ്ങൾ, LED-കൾ, നെറ്റ്‌വർക്ക് മൊഡ്യൂളുകൾ, പവർ സപ്ലൈ ഓപ്ഷനുകൾ, മാനേജ്‌മെന്റ് ഇന്റർഫേസുകൾ എന്നിവ വിശദമായി പ്രതിപാദിക്കുന്നു.
പ്രീview BSS കളറിംഗും OBSS-PD-യും: Wi-Fi 6 ഇടപെടൽ മാനേജ്മെന്റ് ഗൈഡ്
ഈ പ്രമാണം ഒരു ഓവർ നൽകുന്നുview വൈ-ഫൈ 6 (802.11ax) ലെ BSS കളറിംഗ്, ഓവർലാപ്പിംഗ് BSS പാക്കറ്റ് ഡിറ്റക്റ്റ് (OBSS-PD) സവിശേഷതകൾ, സിസ്കോ വയർലെസ് നെറ്റ്‌വർക്കിംഗ് ഉപകരണങ്ങൾക്കായുള്ള അവയുടെ പ്രവർത്തനക്ഷമത, കോൺഫിഗറേഷൻ, സ്ഥിരീകരണം എന്നിവ വിശദമാക്കുന്നു.
പ്രീview സിസ്കോ കാറ്റലിസ്റ്റ് 1000 സീരീസ് സ്വിച്ചുകൾ സംബന്ധിച്ച പതിവ് ചോദ്യങ്ങൾ
സിസ്കോ കാറ്റലിസ്റ്റ് 1000 സീരീസ് ഫിക്സഡ് മാനേജ്ഡ് ലെയർ 2 ഗിഗാബിറ്റ് ഇതർനെറ്റ് സ്വിച്ചുകളെക്കുറിച്ചുള്ള പതിവ് ചോദ്യങ്ങൾ (പതിവ് ചോദ്യങ്ങൾ), പൊതുവായ വിവരങ്ങൾ, ഹാർഡ്‌വെയർ, മാനേജ്‌മെന്റ്, പവർ, PoE, QoS, സുരക്ഷ, ഇന്റലിജന്റ് സേവനങ്ങൾ, വാറന്റി എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview സിസ്കോ ഡിഎൻഎ സേവനത്തിനായുള്ള സിസ്കോ ഫ്ലെക്സ്കണക്ട് ബോൺജോർ ഡിപ്ലോയ്‌മെന്റ് ഗൈഡ്
വയർഡ്, വയർലെസ് പരിതസ്ഥിതികളിലുടനീളം തടസ്സമില്ലാത്ത സേവന കണ്ടെത്തലും വിതരണവും പ്രാപ്തമാക്കുന്ന, സിസ്കോ ഫ്ലെക്സ്കണക്ട് വയർലെസ് നെറ്റ്‌വർക്കുകൾക്കൊപ്പം ബോൺജോറിനായുള്ള സിസ്കോ ഡിഎൻഎ സേവനത്തിന്റെ വിന്യാസം വിശദീകരിക്കുന്ന ഒരു സമഗ്ര ഗൈഡ്.
പ്രീview Trunking Between Catalyst 4500/4000, 5500/5000, and 6500/6000 Series Switches Using 802.1Q Encapsulation with Cisco CatOS System Software
A technical guide detailing the implementation and configuration of IEEE 802.1Q trunking on Cisco Catalyst 4500/4000, 5500/5000, and 6500/6000 series switches using CatOS system software, including step-by-step examples and common error resolution.