സ്റ്റെയ്നൽ 608910

Steinel IS 140-2 Motion Sensor User Manual

Infrared Movement Detector

ആമുഖം

The Steinel IS 140-2 is an infrared-controlled motion detector designed for reliable and efficient movement detection. This manual provides comprehensive instructions for the setup, operation, and maintenance of your device, ensuring optimal performance and longevity. It features a 140° angle of coverage, a range of up to 14 meters, and an optical system that swivels through 180° and tilts through 90° for precise detection zone adjustment. The housing is made of UV-resistant plastic, suitable for both indoor and outdoor use.

Steinel IS 140-2 Motion Sensor front view

ചിത്രം 1: മുൻഭാഗം view of the Steinel IS 140-2 Motion Sensor, showing its compact and discreet design.

സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Proper installation is crucial for the optimal performance of your IS 140-2 motion detector. This device is designed for wall mounting and can be installed quickly and easily.

പാക്കേജ് ഉള്ളടക്കം

Steinel IS 140-2 Motion Sensor package contents

Figure 2: Contents of the Steinel IS 140-2 package, including the sensor unit, mounting hardware, and documentation.

ഇൻസ്റ്റാളേഷൻ ആരംഭിക്കുന്നതിന് മുമ്പ്, എല്ലാ ഘടകങ്ങളും ഉണ്ടെന്ന് ഉറപ്പാക്കുക:

  • Steinel IS 140-2 Motion Sensor unit
  • മൗണ്ടിംഗ് സ്ക്രൂകളും മതിൽ പ്ലഗുകളും
  • Shrouds for detection zone customization
  • Quick Start Guide and Instruction Manual

സെൻസർ മൌണ്ട് ചെയ്യുന്നു

The IS 140-2 can be mounted on a wall or in a corner. Corner wall mounts are available as accessories if needed. Ensure the mounting surface is stable and suitable for the device.

തിരികെ view of Steinel IS 140-2 Motion Sensor with 'TOP' indicator

ചിത്രം 3: പിൻഭാഗം view of the sensor, indicating the "TOP" orientation for correct mounting and cable entry points.

  1. Identify the desired mounting location. Consider the detection area and avoid obstructions.
  2. Mark the drilling points using the sensor's mounting plate as a template.
  3. ആവശ്യമെങ്കിൽ ദ്വാരങ്ങൾ തുരന്ന് വാൾ പ്ലഗുകൾ ഇടുക.
  4. Wire the sensor according to local electrical codes. The sensor is designed for AC power (230 Volts).
  5. Secure the sensor to the wall using the provided screws. Ensure the "TOP" indicator on the back of the unit is oriented correctly.
Steinel IS 140-2 Motion Sensor mounted on a wall

Figure 4: The Steinel IS 140-2 Motion Sensor discreetly mounted on a wall, ready for operation.

സെൻസർ പ്രവർത്തിപ്പിക്കുന്നു

The IS 140-2 motion detector offers flexible adjustments to suit various environmental conditions and detection requirements.

Adjusting Detection Zone and Range

The sensor has a 140° angle of coverage and a maximum range of 14 meters. The optical system can be swiveled through 180° horizontally and tilted through 90° vertically to precisely define the detection area. Shrouds are provided to further customize and limit the detection zone, preventing unwanted triggers.

Diagram showing the 140 degree detection zone and 14 meter range of the motion sensor

Figure 5: Illustration of the sensor's 140° detection angle and maximum 14-meter range from a wall-mounted position.

Setting Time and Luminosity

The sensor features adjustable settings for light sensitivity (luminosity) and the duration the connected light remains on after detection (time). These adjustments are typically made via dials located on the sensor unit.

വശം view of Steinel IS 140-2 Motion Sensor showing adjustment dials

ചിത്രം 6: വശം view of the sensor revealing the adjustment dials for setting time and luminosity thresholds.

  • Luminosity (Lux): Adjusts the ambient light level at which the sensor becomes active. The response value luminosity is 2 to 2000 lx. Turn the dial towards the sun icon for activation in brighter conditions, or towards the moon icon for activation in darker conditions.
  • സമയം (ദൈർഘ്യം): Sets how long the connected light stays on after motion is detected. The adjustable range is from 8 seconds to 35 minutes.
Infographic summarizing key features of Steinel IS 140-2 Motion Sensor

Figure 7: Infographic detailing key specifications such as max wattage (250W LED / 1000W incandescent), 140° infrared sensor, 14m max range, IP54 rating, 90° vertical/180° horizontal sensor adjustment, 2-2000 lux, and 8 sec - 35 min time settings.

For an augmented reality view of the product, scan the QR code or visit: Steinel AR View

മെയിൻ്റനൻസ്

The Steinel IS 140-2 motion sensor is designed for durability and requires minimal maintenance. Its housing is made of UV-resistant plastic, ensuring long-term performance even when exposed to outdoor elements.

  • വൃത്തിയാക്കൽ: ഇടയ്ക്കിടെ സെൻസർ ലെൻസും ഹൗസിംഗും ഒരു സോഫ്റ്റ്, ഡി ക്ലീനർ ഉപയോഗിച്ച് തുടയ്ക്കുക.amp cloth to remove dust and dirt. Avoid using abrasive cleaners or solvents, as these can damage the plastic.
  • പരിശോധന: Regularly check the mounting for stability and ensure no vegetation or objects are obstructing the detection zone.
  • പാരിസ്ഥിതിക പരിഗണനകൾ: While the sensor is robust, extreme weather conditions (e.g., heavy snow, ice buildup) may temporarily affect its performance. Ensure the sensor is clear of such obstructions.

ട്രബിൾഷൂട്ടിംഗ്

If you encounter issues with your Steinel IS 140-2 motion sensor, refer to the following common problems and solutions:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
Light does not switch on when motion is detected.
  • Luminosity setting too high.
  • Detection zone obstructed or incorrectly aimed.
  • വൈദ്യുതി വിതരണ പ്രശ്നം.
  • Connected light bulb faulty.
  • Adjust luminosity dial to a lower setting (towards moon icon).
  • Re-aim the sensor head; clear any obstructions.
  • Check electrical connections and circuit breaker.
  • Test or replace the light bulb.
Light stays on continuously or switches on randomly.
  • Time setting too long.
  • Detection zone too wide, picking up unwanted motion (e.g., trees, traffic).
  • സെൻസർ തകരാർ.
  • Adjust time dial to a shorter duration.
  • Narrow the detection zone using the shrouds or by re-aiming the sensor.
  • If issues persist after adjustments, contact customer support.
Detection range is shorter than expected.
  • Sensor mounted too high or low.
  • Obstructions in the detection path.
  • Temperature differences affecting infrared detection.
  • Ensure optimal mounting height (typically 1.8m - 2.5m).
  • സെൻസറിനെ തടയുന്ന എല്ലാ വസ്തുക്കളും നീക്കം ചെയ്യുക. view.
  • Consider environmental factors; performance may vary slightly with extreme temperatures.

സ്പെസിഫിക്കേഷനുകൾ

Detailed technical specifications for the Steinel IS 140-2 Motion Sensor:

ഫീച്ചർവിശദാംശങ്ങൾ
ബ്രാൻഡ്സ്റ്റീനെൽ
മോഡൽ നമ്പർ608910
നിറംവെള്ള
പവർ ഉറവിടംAC
വാല്യംtage230 വോൾട്ട്
വാട്ട്tagഇ (പരമാവധി)1000 watts (incandescent), 250W (LED, max. 50 pcs)
ഇനത്തിൻ്റെ ഭാരം170 ഗ്രാം (ഏകദേശം 6 ഔൺസ്)
പരമാവധി പരിധി14 മീറ്റർ
കണ്ടെത്തൽ ആംഗിൾ140° Infrared
Optical System AdjustmentSwivels 180° (horizontal), Tilts 90° (vertical)
Luminosity Response Value2 മുതൽ 2000 lx വരെ
സമയ ക്രമീകരണം8 സെക്കൻഡ് മുതൽ 35 മിനിറ്റ് വരെ
മൗണ്ടിംഗ് തരംമതിൽ മൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ (L x W x H)3.9"D x 3.39"W x 3.23"H (ഏകദേശം 99mm x 86mm x 82mm)
IP റേറ്റിംഗ്IP54 (Protection against dust and splashing water)
ഉയർന്ന താപനില റേറ്റിംഗ്50 ഡിഗ്രി സെൽഷ്യസ്
Technical drawing with dimensions of Steinel IS 140-2 Motion Sensor

Figure 8: Technical drawing illustrating the precise dimensions of the Steinel IS 140-2 Motion Sensor in millimeters.

വാറൻ്റിയും പിന്തുണയും

വാറൻ്റി വിവരങ്ങൾ

The Steinel IS 140-2 Motion Sensor comes with a 3-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

ഉപഭോക്തൃ പിന്തുണ

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Steinel customer support. You can find more information and contact details on the official Steinel website or by visiting the Steinel Store on Amazon:

Visit the Steinel Store on Amazon

അനുബന്ധ രേഖകൾ - 608910

പ്രീview STEINEL IS 2360-3 ECO Infrared Ceiling Motion Detector | Specifications & Wiring
Detailed information on the STEINEL IS 2360-3 ECO infrared ceiling motion detector, including its features, technical specifications, detection zone, and wiring diagrams for installation and operation.
പ്രീview STEINEL IS 2180 ECO Infrared Motion Sensor Installation Manual
Installation and user manual for the STEINEL IS 2180 ECO infrared motion sensor. Details features, technical specifications, installation, and troubleshooting for reliable automatic lighting control.
പ്രീview STEINEL IS 2180-2 ഇൻഫ്രാറെഡ് മോഷൻ സെൻസർ ഇൻസ്റ്റലേഷൻ മാനുവൽ
വിശ്വസനീയമായ ലൈറ്റിംഗ് നിയന്ത്രണത്തിനായി ക്രമീകരിക്കാവുന്ന ശ്രേണി, സമയം, പ്രകാശ സംവേദനക്ഷമത എന്നിവ ഉൾക്കൊള്ളുന്ന STEINEL IS 2180-2 ഇൻഫ്രാറെഡ് മോഷൻ സെൻസർ ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനും പ്രവർത്തിപ്പിക്കുന്നതിനുമുള്ള സമഗ്രമായ ഗൈഡ്.
പ്രീview STEINEL IS 2180-2 Infrarot-Bewegungsmelder: Montageanleitung und technische Informationen
ഉംഫാസെൻഡെ മോൺtageanleitung für den STEINEL IS 2180-2 Infrarot-Bewegungsmelder. Enthält technische Daten, Installationsschritte, Funktionsbeschreibungen, Fehlerbehebung und Garantieinformationen. Das Dokument ist in mehreren Sprachen verfügbar, mit Fokus auf Deutsch.
പ്രീview STEINEL IS 2180 ECO Infrared Sensor Installation Guide and Technical Information
Comprehensive installation guide and technical specifications for the STEINEL IS 2180 ECO professional infrared motion sensor. Includes setup, functions, troubleshooting, and warranty information.
പ്രീview STEINEL IS 2180 ECO Infrarot-Sensor: Montageanleitung und Technische Daten
Detaillierte Anleitung für den STEINEL IS 2180 ECO Infrarot-Bewegungsmelder, inklusive Installationsschritten, technischen Spezifikationen, Funktionen und Fehlerbehebung.