Intermatic T101R201

Intermatic T101R201 Time Switch User Manual

Model: T101R201 | Brand: Intermatic

1. ആമുഖം

The Intermatic T101R201 Time Switch is a heavy-duty mechanical timer designed for precise control of electrical loads in commercial, industrial, and residential applications. This robust device provides reliable scheduling with up to 12 ON/OFF operations per day, each with a minimum duration of 1 hour. It is equipped with both ON and OFF trippers for flexible programming and is housed in a durable enclosure suitable for indoor and outdoor use. This manual provides essential information for the safe installation, operation, and maintenance of your time switch.

2 സുരക്ഷാ വിവരങ്ങൾ

മുന്നറിയിപ്പ്: Risk of electrical shock. This device should be installed and serviced by a qualified electrician in accordance with all national and local electrical codes. Failure to follow these instructions could result in serious injury or death.

3. ഉൽപ്പന്ന സവിശേഷതകൾ

4. പാക്കേജ് ഉള്ളടക്കം

ഇൻസ്റ്റാളേഷൻ ആരംഭിക്കുന്നതിന് മുമ്പ് എല്ലാ ഘടകങ്ങളും നിലവിലുണ്ടെന്ന് ഉറപ്പാക്കുക:

Intermatic T101R201 Time Switch with cover open, showing internal mechanism and wiring diagram.
Figure 4.1: Time Switch with cover open, revealing the timer dial, electrical components, and internal wiring diagram on the inside of the cover.
Intermatic T101R201 Time Switch with cover closed, showing the durable metal enclosure.
Figure 4.2: Time Switch with its protective metal cover closed, ready for installation.
Assorted installation accessories including flexible conduit, cable ties, and mounting clips.
ചിത്രം 4.3: ഉദാample of common installation accessories that may be included or required, such as flexible conduit, cable ties, and mounting clips.

5. ഇൻസ്റ്റലേഷനും വയറിംഗും

പ്രധാനപ്പെട്ടത്: Installation must be performed by a qualified electrician. Refer to the wiring diagram located inside the time switch cover for specific connection details. Ensure all local and national electrical codes are strictly followed.

  1. വൈദ്യുതി വിച്ഛേദിക്കൽ: Turn OFF power to the circuit at the main service panel before beginning any work. Verify power is off using a voltagഇ ടെസ്റ്റർ.
  2. മൗണ്ടിംഗ്: Select a suitable location for the time switch, ensuring it is accessible for programming and maintenance, and protected from direct weather if not rated for outdoor exposure. Securely mount the enclosure using appropriate hardware.
  3. വയറിംഗ്:
    • Open the time switch enclosure.
    • Connect the incoming power supply wires to the designated terminals (typically LINE 1 and LINE 2 or L and N for 120V).
    • Connect the load wires (to the appliance or lighting fixture) to the LOAD terminals.
    • Ensure proper grounding by connecting the ground wire to the designated ground terminal.
    • എല്ലാ കണക്ഷനുകളുടെയും ഇറുകിയതും ശരിയായ പോളാരിറ്റിയും രണ്ടുതവണ പരിശോധിക്കുക.
  4. എൻക്ലോഷർ അടയ്ക്കുക: Once wiring is complete and verified, close and secure the enclosure door.
  5. പവർ പുന ore സ്ഥാപിക്കുക: Turn ON power at the main service panel.

6. പ്രവർത്തനവും പ്രോഗ്രാമിംഗും

The T101R201 time switch uses a mechanical dial and trippers for programming ON/OFF cycles.

6.1 നിലവിലെ സമയം ക്രമീകരിക്കുന്നു

  1. Locate the small knob or arrow on the center of the dial.
  2. Rotate the entire dial clockwise until the current time aligns with the time arrow indicator.

6.2 സൈക്കിളുകൾ ഓൺ/ഓഫ് പ്രോഗ്രാമിംഗ്

The time switch comes with ON (green) and OFF (red) trippers. Each tripper represents a 1-hour interval.

  1. To set an ON time: Insert a green ON tripper into the desired time slot on the outer edge of the dial.
  2. To set an OFF time: Insert a red OFF tripper into the desired time slot on the outer edge of the dial.
  3. Ensure there is at least one hour between an ON and OFF tripper for proper operation.
  4. You can program up to 12 ON/OFF cycles per 24-hour period.

6.3 മാനുവൽ അസാധുവാക്കൽ

A manual override lever or switch is typically present to temporarily turn the connected load ON or OFF without affecting the programmed schedule. Consult the specific markings on your unit for manual operation.

7. പരിപാലനം

The Intermatic T101R201 Time Switch is designed for minimal maintenance. However, periodic checks can ensure long-term reliable operation:

8. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
Time switch not operating (no clock movement)No power to the unit; internal motor failure.Check circuit breaker/fuse. Verify wiring connections. If power is present, unit may require replacement.
പ്രോഗ്രാം ചെയ്ത സമയങ്ങളിൽ ലോഡ് ഓൺ/ഓഫ് ആകുന്നില്ല.Incorrect tripper placement; trippers loose; manual override engaged; faulty load.Verify tripper positions and ensure they are securely snapped in. Check manual override switch. Test the connected load independently.
ക്ലോക്ക് വേഗത്തിലോ പതുക്കെയോ പ്രവർത്തിക്കുന്നുആന്തരിക സംവിധാന പ്രശ്നം.The unit may require replacement. Contact a qualified electrician.
Enclosure door not closing properlyObstruction; damaged hinge/latch.Clear any obstructions. Inspect hinges and latches for damage.

For issues not listed above or if solutions do not resolve the problem, contact a qualified electrician or Intermatic customer support.

9 സ്പെസിഫിക്കേഷനുകൾ

മോഡൽ നമ്പർടി101ആർ201
ബ്രാൻഡ്ഇൻ്റർമാറ്റിക്
സ്വിച്ച് തരംSPST (സിംഗിൾ-പോൾ, സിംഗിൾ-ത്രോ)
വാല്യംtage120 V (Clock Supply)
മെറ്റീരിയൽമെറ്റൽ എൻക്ലോഷർ
നിറംWhite (Enclosure)
ഉൽപ്പന്ന അളവുകൾ (D x W x H)11.02" x 2.36" x 2.36"
ഇനത്തിൻ്റെ ഭാരം3.4 പൗണ്ട്
Max ON/OFF Operations per Day12
Minimum ON/OFF Time1 മണിക്കൂർ
Heater Protection Circuit10-Amps, 240-Volt max
യു.പി.സി078275000063

10. വാറൻ്റിയും പിന്തുണയും

Intermatic products are manufactured to high quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official Intermatic webസൈറ്റ്. വാറന്റി ക്ലെയിമുകൾക്കായി നിങ്ങളുടെ വാങ്ങലിന്റെ തെളിവ് സൂക്ഷിക്കുക.

For technical support or further assistance, please contact Intermatic Customer Service. Contact details can typically be found on the manufacturer's webസൈറ്റ് അല്ലെങ്കിൽ ഉൽപ്പന്ന പാക്കേജിംഗിൽ.

ഓൺലൈൻ ഉറവിടങ്ങൾ: www.intermatic.com

അനുബന്ധ രേഖകൾ - ടി101ആർ201

പ്രീview ഫയർമാൻ സ്വിച്ചുള്ള ഇന്റർമാറ്റിക് T101P201/T101R201 24-മണിക്കൂർ സമയ സ്വിച്ച്
പൂൾ ഹീറ്ററുകൾക്കുള്ള ഫയർമാൻ സ്വിച്ച് പ്രവർത്തനക്ഷമതയുള്ള ഇന്റർമാറ്റിക് T101P201 (പ്ലാസ്റ്റിക്), T101R201 (മെറ്റൽ) 24 മണിക്കൂർ ഡയൽ ടൈം സ്വിച്ചുകൾക്കുള്ള വിശദമായ ഗൈഡ്. വയറിംഗ്, പ്രോഗ്രാമിംഗ്, പ്രവർത്തന നിർദ്ദേശങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview ഇന്റർമാറ്റിക് ഇലക്ട്രോണിക് 7-ദിവസത്തെ വാട്ടർ ഹീറ്റർ സമയ സ്വിച്ചുകൾ EH10 EH40 ഉപയോക്തൃ മാനുവൽ
ഇന്റർമാറ്റിക് EH10, EH40 ഇലക്ട്രോണിക് 7-ദിവസ വാട്ടർ ഹീറ്റർ സമയ സ്വിച്ചുകൾക്കായുള്ള സമഗ്ര നിർദ്ദേശ മാനുവൽ. ഇൻസ്റ്റാളേഷൻ, പ്രോഗ്രാമിംഗ്, സ്പെസിഫിക്കേഷനുകൾ, സുരക്ഷ, വാറന്റി വിവരങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview ഇന്റർമാറ്റിക് സ്പ്രിംഗ് വുണ്ട് ഇന്റർവെൽ ടൈമർ ഇൻസ്റ്റാളേഷനും ഓപ്പറേഷൻ ഗൈഡും
ഇന്റർമാറ്റിക് സ്പ്രിംഗ് വൌണ്ട് ഇന്റർവെൽ ടൈമറുകൾക്ക് (FF, FD മോഡലുകൾ) വിശദമായ ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, ആപ്ലിക്കേഷൻ ഗൈഡ്. സ്വിച്ച് റേറ്റിംഗുകൾ, വയറിംഗ് ഡയഗ്രമുകൾ, വാറന്റി വിവരങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview ഇന്റർമാറ്റിക് T105 24-മണിക്കൂർ ഡയൽ ടൈം സ്വിച്ച്: ഇൻസ്റ്റാളേഷൻ, വയറിംഗ്, ഓപ്പറേഷൻ ഗൈഡ്
ഇന്റർമാറ്റിക് T105 24-മണിക്കൂർ മെക്കാനിക്കൽ ഡയൽ ടൈം സ്വിച്ചിനായുള്ള സമഗ്ര ഗൈഡ്. മോഡൽ സ്പെസിഫിക്കേഷനുകൾ, സുരക്ഷാ മുന്നറിയിപ്പുകൾ, വിവിധ കോൺഫിഗറേഷനുകൾക്കുള്ള വയറിംഗ് നിർദ്ദേശങ്ങൾ (SPNO, SPNC, SPDT), പ്രോഗ്രാമിംഗ് നടപടിക്രമങ്ങൾ, മാനുവൽ പ്രവർത്തനം എന്നിവ ഉൾക്കൊള്ളുന്നു. ഇലക്ട്രിക്കൽ റേറ്റിംഗുകളുടെയും വയർ ഗേജ് ശുപാർശകളുടെയും വിശദമായ പട്ടിക ഉൾപ്പെടുന്നു.
പ്രീview ഇന്റർമാറ്റിക് ET270 സീരീസ് ET279C ഇലക്ട്രോണിക് 7-ഡേ ടൈം സ്വിച്ച് മാനുവൽ
ഇന്റർമാറ്റിക് ET270 സീരീസ് ET279C ഇലക്ട്രോണിക് 7-ഡേ ടൈം സ്വിച്ചിനായുള്ള സമഗ്രമായ ഉടമസ്ഥ, ഇൻസ്റ്റാളർ നിർദ്ദേശ മാനുവൽ. സ്പെസിഫിക്കേഷനുകൾ, സുരക്ഷാ വിവരങ്ങൾ, ഇൻസ്റ്റാളേഷൻ, പ്രോഗ്രാമിംഗ്, ട്രബിൾഷൂട്ടിംഗ്, വാറന്റി വിശദാംശങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview ഇന്റർമാറ്റിക് T103 24-മണിക്കൂർ ഡയൽ ടൈം സ്വിച്ച്: ഇൻസ്റ്റാളേഷനും പ്രവർത്തന മാനുവലും
ഇന്റർമാറ്റിക് T103 24-മണിക്കൂർ ഡയൽ ടൈം സ്വിച്ചിനായുള്ള വിശദമായ ഗൈഡ്, സ്പെസിഫിക്കേഷനുകൾ, സുരക്ഷാ മുന്നറിയിപ്പുകൾ, വയറിംഗ് നിർദ്ദേശങ്ങൾ, പ്രോഗ്രാമിംഗ്, പ്രവർത്തനം എന്നിവ ഉൾക്കൊള്ളുന്നു. 120/208/240 VAC പവർ ഉള്ള ഇൻഡോർ ഉപയോഗത്തിന് അനുയോജ്യം.