ആമുഖം
This manual provides instructions for the installation, operation, and maintenance of the Altronix OLS120 Power Supply/Charger. The OLS120 is designed to provide regulated 12VDC or 24VDC power at 4 amps, with integrated AC and battery monitoring capabilities, utilizing a 115VAC input.
പ്രധാനപ്പെട്ട സുരക്ഷാ നിർദ്ദേശങ്ങൾ
- Installation and servicing should only be performed by qualified service personnel.
- To reduce the risk of electric shock, disconnect AC power before servicing.
- അമിതമായി ചൂടാക്കുന്നത് തടയാൻ ശരിയായ വായുസഞ്ചാരം ഉറപ്പാക്കുക.
- മഴയോ ഈർപ്പമോ യൂണിറ്റ് തുറന്നുകാട്ടരുത്.
- Use only recommended battery types for backup power.
ഉൽപ്പന്നം കഴിഞ്ഞുview
The Altronix OLS120 is a robust power supply/charger unit engineered for reliable performance in various applications requiring stable DC power and battery backup.
പ്രധാന സവിശേഷതകൾ
- Selectable 12VDC or 24VDC output.
- 4 amp continuous supply current.
- Integrated AC and battery monitoring.
- 115VAC input for power.
ഘടകം തിരിച്ചറിയൽ

This image displays the Altronix OLS120 circuit board, highlighting various components essential for its operation. Familiarize yourself with these components before installation.
പ്രധാന ഘടകങ്ങൾ:
- വാല്യംtagഇ സെലക്ടർ സ്വിച്ച്: Located at the top right, labeled "OFF 24VDC ON 12VDC". This switch allows selection between 12VDC and 24VDC output.
- AC Input Terminals: Positioned at the bottom left, marked for 115VAC input connections.
- DC ഔട്ട്പുട്ട് ടെർമിനലുകൾ: Located at the bottom right, these terminals are for connecting devices that require 12VDC or 24VDC power.
- ബാറ്ററി ടെർമിനലുകൾ: Found at the bottom right, near the PTCs, for connecting backup batteries.
- AC Fail Indicator (LED): An LED near the "AC FAL" label, which illuminates upon loss of AC power.
- Low Battery Indicator (LED): An LED near the "LOW BAT" label, indicating a low battery condition.
- ട്രാൻസ്ഫോർമർ: A central component, often labeled with part numbers like "P POL-30030", responsible for stepping down the AC voltage.
- കപ്പാസിറ്ററുകൾ: Large cylindrical components (e.g., "C2", "C29A") used for filtering and energy storage.
- Fuses/PTCs: Overcurrent protection devices (e.g., "PTC1", "PTC2") to safeguard the circuit.
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
ഘട്ടം 1: മൗണ്ടിംഗ്
Securely mount the OLS120 in a suitable enclosure or location, ensuring adequate ventilation to prevent heat buildup.
ഘട്ടം 2: വാല്യംtagഇ സെലക്ഷൻ
വോളിയം കണ്ടെത്തുകtage selector switch (labeled "OFF 24VDC ON 12VDC") on the circuit board. Set the switch to the desired output voltage (12VDC or 24VDC) before connecting any power.
Step 3: AC Power Connection
Connect the 115VAC input power to the designated AC input terminals. Ensure proper polarity and secure connections. Refer to local electrical codes for wiring practices.
Step 4: DC Output Connection
Connect your devices requiring DC power to the DC output terminals. Observe correct polarity to prevent damage to the connected equipment.
Step 5: Battery Connection (Optional)
For battery backup functionality, connect a suitable rechargeable battery to the battery terminals. Ensure correct polarity. The OLS120 will charge the battery and automatically switch to battery power upon AC failure.
ഓപ്പറേഷൻ
പവർ ചെയ്യുന്നു
Once all connections are secure and verified, apply 115VAC power to the unit. The unit will power on and begin providing regulated DC output.
സ്റ്റാറ്റസ് സൂചകങ്ങൾ
- AC Fail (LED): This indicator illuminates when the AC input power is lost, signaling that the unit is operating on battery backup (if connected).
- Low Bat (LED): This indicator illuminates when the connected battery voltage drops below a pre-set threshold, indicating that the battery requires charging or replacement.
മെയിൻ്റനൻസ്
ജനറൽ കെയർ
Keep the unit clean and free from dust accumulation. Ensure that all ventilation openings are not obstructed to maintain optimal operating temperature.
ബാറ്ററി പരിപാലനം
If a backup battery is used, periodically check its condition and charge level. Replace the battery as recommended by the battery manufacturer or when its performance degrades.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| ഡിസി ഔട്ട്പുട്ട് ഇല്ല | എസി ഇൻപുട്ട് പവർ ഇല്ല | Check AC power source and connections. |
| ഡിസി ഔട്ട്പുട്ട് ഇല്ല | തെറ്റായ വോളിയംtagഇ സെലക്ഷൻ | വോളിയം പരിശോധിക്കുകtage selector switch is set correctly (12VDC or 24VDC). |
| AC Fail LED On | Loss of AC power | Restore AC power. |
| Low Bat LED On | ഡിസ്ചാർജ് ചെയ്തതോ തകരാറുള്ളതോ ആയ ബാറ്ററി | Check battery charge and condition; replace if necessary. |
| ഇടവിട്ടുള്ള ഔട്ട്പുട്ട് | അയഞ്ഞ കണക്ഷനുകൾ | Secure all wiring connections. |
For issues not listed above, or if troubleshooting steps do not resolve the problem, please contact Altronix technical support for further assistance.
സ്പെസിഫിക്കേഷനുകൾ
- ഉൽപ്പന്ന അളവുകൾ: 8.4 x 5.7 x 2.9 ഇഞ്ച്
- ഇനത്തിൻ്റെ ഭാരം: 1.2 പൗണ്ട്
- Putട്ട്പുട്ട് വോളിയംtage: 12VDC or 24VDC (selectable)
- ഔട്ട്പുട്ട് കറൻ്റ്: 4 amp
- ഇൻപുട്ട് വോളിയംtage: 115VAC
- നിർമ്മാതാവ്: ആൾട്രോണിക്സ്
- മോഡൽ നമ്പർ: OLS120D2X ന്റെ സവിശേഷതകൾ
- ആദ്യം ലഭ്യമായ തീയതി: ജൂലൈ 31, 2010
വാറന്റിയും സാങ്കേതിക പിന്തുണയും
Altronix products are backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the official Altronix webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ വാങ്ങലിൽ ഉൾപ്പെടുത്തിയിരിക്കുന്ന ഡോക്യുമെന്റേഷൻ.
For technical assistance, product inquiries, or support, please contact Altronix customer service directly. Contact information can typically be found on the manufacturer's webസൈറ്റ്.
Manufacturer: Altronix Corp.