പെന്റെയർ 59002400

Pentair 59002400 D.E. Filter Grid Assembly Instruction Manual

മോഡൽ: 59002400

1. ആമുഖം

This manual provides essential information for the proper installation, operation, and maintenance of your Pentair 59002400 24-Inch Large Full Grid Assembly. This component is designed for use with Pentair FNS, FNS Plus, Nautilus, and Nautilus Plus 48 square feet D.E. filters. Please read these instructions thoroughly before proceeding to ensure safe and efficient use of your pool or spa filtration system.

സുരക്ഷാ അറിയിപ്പ്:

Always turn off the pool pump and relieve all pressure from the filter system before performing any maintenance or installation. Failure to do so can result in serious injury or property damage. Consult a qualified pool professional if you are unsure about any steps.

2. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Pentair 59002400 is a large, 24-inch full grid assembly designed as a replacement part for specific Pentair D.E. (Diatomaceous Earth) filters. It is crucial for the filtration process, holding the D.E. powder that traps microscopic particles from your pool or spa water.

  • അനുയോജ്യത: Specifically designed for Pentair FNS, FNS Plus, Nautilus, and Nautilus Plus 48 square feet D.E. filters.
  • പ്രവർത്തനം: Forms the internal structure of the D.E. filter, supporting the D.E. media for effective water purification.
  • വലിപ്പം: Measures 24 inches in height.
Pentair 59002400 24-Inch Large Full Grid Assembly

Figure 2.1: The Pentair 59002400 24-inch large full grid assembly. This image shows the complete white grid assembly, which is a critical component for D.E. pool and spa filters, responsible for holding the diatomaceous earth filtration media.

3. Installation (Replacement)

This section outlines the general procedure for replacing a D.E. filter grid assembly. Always refer to your specific Pentair filter model's manual for detailed instructions, as procedures may vary slightly.

  1. സിസ്റ്റം തയ്യാറാക്കുക:
    • Turn off the pool pump and any automatic controls.
    • Open the air relief valve on top of the filter to release any trapped air.
    • Open the filter drain plug to drain the water from the filter tank.
  2. Open the Filter Tank:
    • Remove the filter tank clamp or band, following your filter model's instructions.
    • Carefully lift the top half of the filter tank off.
  3. Remove Old Grid Assembly:
    • Lift out the entire grid assembly from the bottom tank.
    • Inspect the manifold and grids for any damage or wear.
  4. Install New Grid Assembly:
    • Ensure the new Pentair 59002400 grid assembly is clean and free of debris.
    • Carefully lower the new grid assembly into the bottom filter tank, ensuring it seats correctly on the standpipe.
  5. Reassemble Filter Tank:
    • Replace the filter tank O-ring (lubricate if necessary) and position the top half of the tank.
    • Secure the filter tank clamp or band, ensuring it is properly tightened according to manufacturer specifications.
    • Close the filter drain plug.
  6. സ്റ്റാർട്ടപ്പ്:
    • എയർ റിലീഫ് വാൽവ് തുറക്കുക.
    • പൂൾ പമ്പ് ഓണാക്കുക.
    • Once a steady stream of water emerges from the air relief valve, close it.
    • Add the appropriate amount of D.E. powder to the skimmer, as specified by your filter manufacturer.

Video 3.1: This video, provided by Cryspool, demonstrates the replacement process for D.E. filter grids compatible with models like Pentair FNS Plus 48, Jandy DEL/DEV 48, and Pro-Grid DE4820. It illustrates the general steps involved in disassembling and reassembling a D.E. filter to replace the grid elements.

4. Operation (D.E. Filter System)

Once the grid assembly is installed and the filter is reassembled, the D.E. filter system operates by coating the grids with diatomaceous earth powder. This powder acts as the primary filter medium.

  • D.E. Powder Addition: After initial setup or backwashing, D.E. powder must be added to the skimmer. The pump draws the D.E. into the filter tank, where it coats the grids.
  • ഫിൽട്രേഷൻ സൈക്കിൾ: Water passes through the D.E. coated grids, trapping impurities. Clean water is returned to the pool.
  • പ്രഷർ മോണിറ്ററിംഗ്: Regularly monitor the filter pressure gauge. An increase in pressure indicates that the D.E. grids are becoming clogged with debris and require cleaning.

5. പരിപാലനം

Proper maintenance of your D.E. filter grid assembly ensures optimal filtration performance and extends the life of your filter system.

  1. ബാക്ക് വാഷിംഗ്:
    • Backwash your D.E. filter when the pressure gauge reads 8-10 PSI above its clean starting pressure.
    • Follow your filter's specific backwashing procedure, which typically involves reversing water flow to dislodge D.E. and debris.
    • After backwashing, always add new D.E. powder to recoat the grids.
  2. Chemical Cleaning (Annual):
    • At least once a year, or more frequently if needed, the grid assembly should be removed and chemically cleaned.
    • Soak the grids in a specialized filter cleaning solution to remove oils, scale, and other stubborn deposits that backwashing cannot eliminate.
    • Rinse thoroughly after chemical cleaning.
  3. പരിശോധന:
    • During annual cleaning, inspect the grids for tears, holes, or damage to the fabric.
    • Check the manifold for cracks or broken elements.
    • Replace any damaged components immediately to prevent D.E. from returning to the pool or compromising filtration.

6. പ്രശ്‌നപരിഹാരം

This section addresses common issues related to D.E. filter grid assemblies.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
D.E. returning to poolTorn or damaged filter grids; improperly seated grid assembly; cracked manifold.Inspect and replace damaged grids or manifold. Ensure grid assembly is correctly seated.
Poor water clarityInsufficient D.E. powder; clogged grids; damaged grids allowing debris bypass.Add correct amount of D.E. Backwash and chemically clean grids. Inspect and replace damaged grids.
ഉയർന്ന ഫിൽട്ടർ മർദ്ദംClogged grids due to debris or scale buildup.Backwash the filter. If pressure remains high, perform a chemical cleaning of the grids.

7 സ്പെസിഫിക്കേഷനുകൾ

  • മോഡൽ നമ്പർ: 59002400
  • ഉൽപ്പന്ന തരം: Full Grid Assembly Replacement
  • വലിപ്പം: 24-ഇഞ്ച്
  • അനുയോജ്യത: Pentair FNS, FNS Plus, Nautilus, Nautilus Plus 48 square feet D.E. filters
  • അളവുകൾ: Approximately 6 x 4 x 6 inches (packaging/shipping dimensions)
  • ഇനത്തിൻ്റെ ഭാരം: ഏകദേശം 2 പൗണ്ട്
  • നിർമ്മാതാവ്: പെൻ്റയർ

8. വാറൻ്റിയും പിന്തുണയും

For warranty information and technical support regarding your Pentair 59002400 D.E. Filter Grid Assembly, please refer to the official Pentair website or contact Pentair customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

You can visit the official Pentair store for more information: Pentair Store on Amazon

അനുബന്ധ രേഖകൾ - 59002400

പ്രീview Pentair FNS Plus Vertical Grid D.E. Filter Maintenance Guide
Detailed maintenance instructions for the Pentair FNS Plus Vertical Grid D.E. Filter, covering manual cleaning procedures and steps for systems with separation tanks.
പ്രീview Pentair FNS Plus Vertical Grid D.E. Filter: Installation and User's Guide
Comprehensive guide for the installation, operation, and maintenance of the Pentair FNS Plus Vertical Grid D.E. Filter. Includes safety instructions, troubleshooting, and technical data.
പ്രീview പെന്റെയർ ക്ലീൻ ആൻഡ് ക്ലിയർ പ്ലസ് കാട്രിഡ്ജ് ഫിൽട്ടർ: ഇൻസ്റ്റാളേഷനും ഉപയോക്തൃ ഗൈഡും
പെന്റെയർ ക്ലീൻ ആൻഡ് ക്ലിയർ പ്ലസ് കാട്രിഡ്ജ് ഫിൽട്ടറിനായുള്ള സമഗ്രമായ ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, പരിപാലന ഗൈഡ്. സുരക്ഷാ നിർദ്ദേശങ്ങൾ, ട്രബിൾഷൂട്ടിംഗ്, സാങ്കേതിക ഡാറ്റ, മാറ്റിസ്ഥാപിക്കൽ ഭാഗങ്ങൾ എന്നിവയുടെ വിവരങ്ങൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview Pentair T40-FN Automatic Pool Filler for Vanishing Edge Pools - Installation Guide
Learn about the Pentair T40-FN Automatic Pool Filler, designed for vanishing edge pools. This guide provides installation details and safety warnings for ensuring proper integration with catch basins and rebar.
പ്രീview Pentair Clean and Clear Plus Cartridge Filter Installation and User's Guide
Comprehensive installation, operation, and maintenance guide for the Pentair Clean and Clear Plus Cartridge Filter, including safety instructions, troubleshooting, and technical specifications.
പ്രീview Pentair Clean & Clear RP Filters Replacement Parts List
Detailed replacement parts list for Pentair Clean & Clear RP Filters, including part numbers and descriptions for components such as lids, O-rings, cartridges, unions, and relief valves. Features an exploded view ഡയഗ്രം വിവരണം.