1. ആമുഖം
This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of the Legrand 412544 CX3 Contactor. Please read this manual thoroughly before installation and use, and retain it for future reference. This device is designed for controlling electrical circuits, typically for switching loads in residential, commercial, or industrial applications.
2 സുരക്ഷാ വിവരങ്ങൾ
മുന്നറിയിപ്പ്: Electrical installation and maintenance should only be performed by qualified and authorized personnel. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Always disconnect power at the main circuit breaker or fuse box before installing, servicing, or removing the contactor.
- എല്ലാ വയറിംഗും പ്രാദേശിക, ദേശീയ വൈദ്യുത കോഡുകൾ പാലിക്കുന്നുണ്ടെന്ന് ഉറപ്പാക്കുക.
- വോളിയം പരിശോധിക്കുകtage and current ratings of the contactor are suitable for the intended application.
- കോൺടാക്റ്റർ കേടായതായി തോന്നിയാൽ അത് പ്രവർത്തിപ്പിക്കരുത്.
- ഇൻസ്റ്റാളേഷൻ, അറ്റകുറ്റപ്പണികൾ എന്നിവയ്ക്കിടെ ഉചിതമായ വ്യക്തിഗത സംരക്ഷണ ഉപകരണങ്ങൾ (പിപിഇ) ഉപയോഗിക്കുക.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Legrand 412544 CX3 Contactor is a modular device designed for DIN rail mounting. It features two Normally Open (NO) contacts and is rated for 25 Amperes at 230-250 Volts AC. The contactor includes a manual override function for testing or temporary operation.

ചിത്രം 1: Legrand 412544 CX3 Contactor. This image displays the Legrand 412544 CX3 Contactor. Visible features include the 25A rating, 250V operating voltage, and the Legrand brand logo. The front panel shows the manual override lever with 'AUTO' and 'O' (Off) positions, and screw terminals labeled A1, A2 for the coil, and 1, 2, 3, 4 for the main contacts.
പ്രധാന സവിശേഷതകൾ:
- ബന്ധപ്പെടാനുള്ള തരം: 2 Normally Open (NO) contacts
- Rated Current (I max): 25 എ
- ഓപ്പറേറ്റിംഗ് വോളിയംtagഇ (യുഇ): 230-250 വി എസി
- കൺട്രോൾ വോളിയംtage: 230 V എസി
- മൊഡ്യൂളുകളുടെ എണ്ണം: 1 (for DIN rail mounting)
- ഓപ്പറേറ്റിംഗ് മോഡ്: ഓൺ-ഓഫ്
- ടെർമിനൽ തരം: സ്ക്രൂ ടെർമിനലുകൾ
- ആക്യുവേറ്റർ തരം: പിസ്റ്റൺ
- കോൺടാക്റ്റ് മെറ്റീരിയൽ: അലോയ് സ്റ്റീൽ
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Before proceeding, ensure power is disconnected as per Section 2, "Safety Information."
4.1 മൗണ്ടിംഗ്
- Locate an appropriate position on a standard DIN rail within an electrical enclosure.
- Clip the contactor onto the DIN rail. Ensure it is securely fastened.
4.2 വയറിംഗ്
The contactor features screw terminals for secure electrical connections. Refer to the markings on the device for correct wiring.
- Coil Terminals (Control Circuit): നിയന്ത്രണ വോള്യം ബന്ധിപ്പിക്കുകtage (230V AC) to terminals A1 ഒപ്പം A2. A1 is typically for the phase/live wire, and A2 for the neutral.
- Main Contacts (Power Circuit):
- Connect the incoming power supply to terminals 1 ഒപ്പം 3.
- ലോഡ് ടെർമിനലുകളുമായി ബന്ധിപ്പിക്കുക 2 ഒപ്പം 4.
- അയഞ്ഞ കോൺടാക്റ്റുകളും അമിതമായി ചൂടാകുന്നതും തടയാൻ എല്ലാ കണക്ഷനുകളും ഇറുകിയതും സുരക്ഷിതവുമാണെന്ന് ഉറപ്പാക്കുക.
- Double-check all wiring against the electrical diagram of your installation before restoring power.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed and wired correctly, the contactor operates by applying voltage to its control coil (A1-A2).
- യാന്ത്രിക പ്രവർത്തനം: നിയന്ത്രണം വോള്യം എപ്പോൾtage (230V AC) is applied to terminals A1 and A2, the contactor coil energizes, closing the main contacts (1-2 and 3-4). This allows power to flow to the connected load. When the control voltage is removed, the coil de-energizes, and the contacts open, disconnecting the load.
- മാനുവൽ അസാധുവാക്കൽ: The contactor is equipped with a manual override lever on the front panel.
- Move the lever to the 'AUTO' position for normal automatic operation via the control circuit.
- Move the lever to the 'O' (Off) position to manually open the contacts, regardless of the control circuit status. This can be used for maintenance or to ensure the load remains off.
- Some models may also feature a manual 'ON' position for continuous closure of contacts, independent of the control circuit. Refer to the specific markings on your device.
6. പരിപാലനം
The Legrand 412544 CX3 Contactor is designed for reliable, long-term operation with minimal maintenance. However, periodic checks are recommended.
- വിഷ്വൽ പരിശോധന: ശാരീരിക ക്ഷതം, നിറവ്യത്യാസം, അല്ലെങ്കിൽ അയഞ്ഞ കണക്ഷനുകൾ എന്നിവയുടെ ലക്ഷണങ്ങൾക്കായി കോൺടാക്റ്റർ ഇടയ്ക്കിടെ പരിശോധിക്കുക.
- ടെർമിനൽ ടൈറ്റ്നെസ്: Ensure all screw terminals remain tight. Loose connections can lead to overheating and potential failure.
- വൃത്തിയാക്കൽ: If necessary, gently clean the exterior of the contactor with a dry, lint-free cloth. Do not use liquids or abrasive cleaners.
- പ്രവർത്തനക്ഷമത പരിശോധന: With power disconnected from the load circuit, test the manual override function to ensure smooth operation.
പ്രധാനപ്പെട്ടത്: ഏതെങ്കിലും അറ്റകുറ്റപ്പണികൾ നടത്തുന്നതിന് മുമ്പ് എല്ലായ്പ്പോഴും വൈദ്യുതി വിച്ഛേദിക്കുക.
7. പ്രശ്നപരിഹാരം
If the contactor is not functioning as expected, consider the following common issues and solutions:
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| കോൺടാക്റ്റർ ഊർജ്ജസ്വലമാക്കുന്നില്ല (കോൺടാക്റ്റുകൾ അടയ്ക്കുന്നില്ല) |
|
|
| കോൺടാക്റ്റർ ഊർജ്ജസ്വലമാക്കുന്നു, പക്ഷേ ലോഡിന് പവർ ലഭിക്കുന്നില്ല. |
|
|
| Contactor makes humming noise |
|
|
If problems persist after attempting these solutions, contact a qualified electrician or Legrand customer support.
8 സ്പെസിഫിക്കേഷനുകൾ
| ബ്രാൻഡ് | ലെഗ്രാൻഡ് |
| മോഡൽ നമ്പർ | 412544 |
| Rated Current (I max) | 25 എ |
| ഓപ്പറേറ്റിംഗ് വോളിയംtagഇ (യുഇ) | 230-250 വി എസി |
| കൺട്രോൾ വോളിയംtage | 230 V എസി |
| ബന്ധപ്പെടാനുള്ള തരം | 2 സാധാരണയായി തുറക്കുക (ഇല്ല) |
| മൊഡ്യൂളുകളുടെ എണ്ണം | 1 |
| ഓപ്പറേറ്റിംഗ് മോഡ് | ഓൺ-ഓഫ് |
| ടെർമിനൽ തരം | സ്ക്രൂ ടെർമിനലുകൾ |
| സർക്യൂട്ട് തരം | 2-വഴി |
| ആക്യുവേറ്റർ തരം | പിസ്റ്റൺ |
| കോൺടാക്റ്റ് മെറ്റീരിയൽ | അലോയ് സ്റ്റീൽ |
| മൗണ്ടിംഗ് | DIN റെയിൽ |
9. വാറൻ്റിയും പിന്തുണയും
For information regarding product warranty, technical support, or service, please refer to the official Legrand website or contact your local Legrand distributor. Keep your purchase receipt as proof of purchase.
ലെഗ്രാൻഡ് Webസൈറ്റ്: www.legrand.com