The Johnson Controls P70AA-118C is a robust pressure control designed for commercial refrigeration and air conditioning applications. Its primary functions include high pressure cut-out control, head-pressure control, and condenser fan cycling. This control is compatible with most common non-corrosive refrigerants and can also be utilized in other non-corrosive fluid applications. It features a single-pole, single-throw (SPST) switch configuration and is designed for a pressure range of 100 to 400 psi.

Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

Figure 1: Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

The P70AA-118C control unit and its dedicated mounting bracket.

Figure 2: The P70AA-118C control unit and its dedicated mounting bracket.

2 പ്രധാന സവിശേഷതകൾ

  • All-steel case and cover: Provides long-lasting, rugged protection for internal components, ensuring durability in demanding environments.
  • Sight-set calibrated pressure adjustment: Features a visible pressure scale that is fully adjustable through the range without requiring removal of the cover (on NEMA 1 enclosure models), simplifying setup.
  • Manual reset lockout option: Offers a trip-free lockout mechanism that prevents overriding or resetting until the pressure returns to the specified safe level, enhancing system safety.
  • Variety of available pressure connection styles: Allows for greater flexibility during mounting and adaptation of pressure connections to various field application requirements.
Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

Figure 3: Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

3 സ്പെസിഫിക്കേഷനുകൾ

സ്പെസിഫിക്കേഷൻമൂല്യം
മോഡൽ നമ്പർP70AA-118C
ബ്രാൻഡ്ജോൺസൺ കൺട്രോൾസ്
സമ്മർദ്ദ ശ്രേണി100 മുതൽ 400 വരെ psi
കാപ്പിലറി നീളം36 ഇഞ്ച്
Flare Nut Size1/4 ഇഞ്ച്
സ്വിച്ച് തരംSingle-Pole, Single-Throw (SPST)
മെറ്റീരിയൽഉരുക്ക്
ഇനത്തിൻ്റെ ഭാരം1.49 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ10.25 x 2.75 x 4.37 ഇഞ്ച്
ഡിസ്പ്ലേ തരംഅനലോഗ്
നിർമ്മാതാവ്ജോൺസൺ കൺട്രോൾസ്
ആദ്യ തീയതി ലഭ്യമാണ്ഒക്ടോബർ 11, 2012
Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

Figure 4: Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

4. ഇൻസ്റ്റലേഷൻ

Installation of the P70AA-118C control should be performed by a qualified HVAC technician or electrician in accordance with all local and national electrical codes. Ensure the power supply to the system is disconnected before beginning any installation work.

4.1 മൗണ്ടിംഗ്

Mount the control unit in a location that is easily accessible for adjustments and maintenance, yet protected from physical damage and excessive vibration. Use the provided mounting bracket and appropriate fasteners to secure the unit firmly.

അടിവശം view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

ചിത്രം 5: അടിവശം view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

4.2 Capillary Tube Connection

Carefully route the 36-inch capillary tube to the desired pressure sensing point. Avoid sharp bends or kinks that could damage the tube. Connect the 1/4 inch flare nut to the system's pressure port, ensuring a tight, leak-free seal. Do not overtighten.

കോണാകൃതിയിലുള്ളത് view of the P70AA-118C control, highlighting the capillary tube connection.

ചിത്രം 6: കോണാകൃതിയിലുള്ളത് view of the P70AA-118C control, highlighting the capillary tube connection.

Detail of the capillary tube and 1/4 inch flare nut connection.

Figure 7: Detail of the capillary tube and 1/4 inch flare nut connection.

4.3 ഇലക്ട്രിക്കൽ വയറിംഗ്

Refer to the wiring diagram provided with the control unit or the system's specific schematics. Connect the electrical wiring to the appropriate terminals within the control's enclosure. Ensure all connections are secure and properly insulated. The P70AA-118C is a single-pole, single-throw (SPST) control.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Once installed and wired, the P70AA-118C control can be adjusted to the desired operating parameters. The control features a sight-set calibrated pressure adjustment for easy setting.

5.1 Setting Pressure Range

The control allows for adjustment of both the cut-out (high pressure limit) and the differential (the difference between cut-in and cut-out pressures). Use a flat-head screwdriver to adjust the set points visible through the window on the front panel. The scale indicates the pressure in PSI.

5.2 Manual Reset Lockout

If the control is equipped with a manual reset lockout, it will trip and lock the system off if the pressure exceeds a critical threshold. To reset, the pressure must return to a safe level, and then the manual reset button must be pressed. This feature prevents automatic restarts under unsafe conditions.

6. പരിപാലനം

Regular maintenance ensures the longevity and reliable operation of your Johnson Controls P70AA-118C unit. Perform the following checks periodically:

  • വിഷ്വൽ പരിശോധന: Check the control unit, capillary tube, and electrical connections for any signs of wear, corrosion, or damage.
  • ശുചിത്വം: Keep the control unit clean and free from dust, dirt, and debris, which can affect performance.
  • കണക്ഷൻ സമഗ്രത: Ensure all electrical and pressure connections remain tight and secure.
  • പ്രവർത്തനക്ഷമത പരിശോധന: Periodically verify that the control is cycling the fan or cutting out at the set pressure points as expected.

7. പ്രശ്‌നപരിഹാരം

If you encounter issues with your P70AA-118C control, consider the following common troubleshooting steps. For complex issues, always consult a qualified technician.

  • Control Not Cycling Fan:
    • Verify power supply to the control.
    • Check pressure settings; ensure they are within the system's operating range and the control's capabilities.
    • Inspect capillary tube for kinks or leaks.
    • Check electrical connections for looseness or corrosion.
  • കൃത്യമല്ലാത്ത പ്രഷർ റീഡിംഗുകൾ:
    • Ensure the capillary tube is properly connected and not damaged.
    • Verify the system's actual pressure with a calibrated gauge.
  • Control Trips Frequently:
    • Check for system overpressure conditions.
    • Review the set pressure and differential settings.
    • If equipped, ensure the manual reset lockout is not being triggered by transient pressure spikes.

8. വാറൻ്റിയും പിന്തുണയും

For detailed warranty information, please refer to the official documentation provided by Johnson Controls at the time of purchase or visit the Johnson Controls official website. Support for the P70AA-118C control can be obtained through authorized distributors or by contacting Johnson Controls customer service directly.

Product packaging label displaying the model number P70AA-118C and barcode.

Figure 8: Product packaging label displaying the model number P70AA-118C and barcode (UCC/EAN Code 128: 1078502829326).

Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

Figure 9: Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

അനുബന്ധ രേഖകൾ - P70AA-118C

പ്രീview ജോൺസൺ കൺട്രോൾസ് P70, P72, P170 സീരീസ് ഹൈ പ്രഷർ കൺട്രോളുകൾ
വിശദമായി പറഞ്ഞുview ഉയർന്ന മർദ്ദമുള്ള ആപ്ലിക്കേഷനുകൾക്കായുള്ള ജോൺസൺ കൺട്രോൾസ് PENN P70, P72, P170 സീരീസ് ഇലക്ട്രോ മെക്കാനിക്കൽ പ്രഷർ കൺട്രോളുകളുടെ ഒരു ശ്രേണി. റഫ്രിജറേഷൻ, HVAC സിസ്റ്റങ്ങൾക്കായുള്ള സവിശേഷതകൾ, ആപ്ലിക്കേഷനുകൾ, സെലക്ഷൻ ചാർട്ടുകൾ, ക്രോസ്-റഫറൻസുകൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview Johnson Controls Series 100 Single Package Units: Engineering Guide
Comprehensive engineering guide for Johnson Controls Series 100 Single Package Units, covering capacities from 70 to 105 tons. Details features, benefits, application data, nomenclature, and technical specifications for these energy-efficient HVAC units.
പ്രീview Johnson Controls Series 100 Single Package Units Engineering Guide
Comprehensive engineering guide for Johnson Controls Series 100 Single Package Units (70-130 tons). Details features, application data, physical specifications, and cooling performance data for efficient HVAC solutions.
പ്രീview Johnson Controls Controller Tool Help for HVAC Systems
This comprehensive help document provides detailed guidance for the Johnson Controls Controller Tool, covering configuration, simulation, commissioning, and troubleshooting of VAV Single Duct and other HVAC applications. It assists professionals in managing building automation systems effectively.
പ്രീview ഉപയോക്തൃ വിവര മാനുവൽ: ഔട്ട്ഡോർ സ്പ്ലിറ്റ്-സിസ്റ്റം എയർ കണ്ടീഷനിംഗും ഹീറ്റ് പമ്പും
ജോൺസൺ കൺട്രോൾസ് ഡക്റ്റഡ് സിസ്റ്റംസ് ഔട്ട്ഡോർ സ്പ്ലിറ്റ്-സിസ്റ്റം എയർ കണ്ടീഷനിംഗ്, ഹീറ്റ് പമ്പ് യൂണിറ്റുകൾ എന്നിവയ്ക്കുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, പ്രവർത്തനം, സുരക്ഷാ മാർഗ്ഗനിർദ്ദേശങ്ങൾ, സിസ്റ്റം പ്രവർത്തനങ്ങൾ, അറ്റകുറ്റപ്പണികൾ, ട്രബിൾഷൂട്ടിംഗ്, പരിമിതമായ വാറന്റി വിവരങ്ങൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview AHE Series Single Piece Air Handler ECM Motor Flex Coil Models Parts List
Detailed parts list and diagram for Johnson Controls AHE Series Single Piece Air Handler with Standard ECM Motor and Flex Coil Models (Style A). Includes component descriptions and part numbers for various models.