1. ഉൽപ്പന്നം കഴിഞ്ഞുview
The APC Smart-UPS X SMX120RMBP2U is a high-quality external battery backup unit designed to provide clean and reliable network-grade power, protecting critical data and equipment from power problems. This unit offers extended run options, making it ideal for servers, storage, and networks with varying load consumption. It features legendary reliability, manageability, and high efficiency across low, medium, and high load levels.

Figure 1: APC Smart-UPS X SMX120RMBP2U External Battery Backup Unit
2 സുരക്ഷാ വിവരങ്ങൾ
Always read and understand all instructions before installing or operating this unit. Failure to do so may result in injury or equipment damage. This unit contains sealed lead-acid batteries. Do not open or mutilate batteries. Released electrolyte is harmful to skin and eyes. It may be toxic. Always ensure the unit is unplugged from the main power source before performing any maintenance or battery replacement. Refer to local regulations for proper disposal of batteries.
3. പാക്കേജ് ഉള്ളടക്കം
അൺപാക്ക് ചെയ്യുമ്പോൾ എല്ലാ ഘടകങ്ങളും ഉണ്ടെന്ന് ഉറപ്പാക്കുക:
- APC Smart-UPS X SMX120RMBP2U External Battery Backup Unit
- ഉപയോക്തൃ മാനുവൽ (ഈ പ്രമാണം)
- Necessary connection cables
4. സജ്ജീകരണം
4.1 പ്രാരംഭ ബാറ്ററി കണക്ഷൻ
Upon receiving your UPS, the internal battery may be disconnected for safety during shipping. You will need to connect the battery before initial use. Refer to the instructions below for proper connection.
വീഡിയോ 1: കഴിഞ്ഞുview of APC UPS for SmartHome Devices. This video demonstrates the general concept of UPS usage for home devices, including initial setup considerations.
4.2 Connecting to Power and Devices
- Plug the UPS power cord directly into a properly grounded wall outlet. Avoid using extension cords.
- Connect your critical equipment (servers, network devices) to the battery backup outlets (typically labeled). These outlets provide power during outages.
- Connect non-critical equipment to the surge-only outlets. These outlets provide surge protection but no battery backup.
- For automatic computer shutdown during extended power outages, connect the provided data cable from the UPS data port to your computer. Install the APC PowerChute software (available from the manufacturer's webസൈറ്റ്) നിങ്ങളുടെ കമ്പ്യൂട്ടറിൽ.
5. ഓപ്പറേഷൻ
5.1 ഓൺ/ഓഫ് ചെയ്യുന്നു
- To turn on the UPS: Press and hold the power button until the display illuminates.
- To turn off the UPS: Press and hold the power button until the display turns off.
5.2 വിവരങ്ങൾ പ്രദർശിപ്പിക്കുക
The front panel display provides real-time information about the UPS status:
- ഓൺ ലൈനിൽ: Indicates the UPS is receiving utility power.
- ലോഡ്: ശതമാനം കാണിക്കുന്നുtage of connected load.
- ബാറ്ററി ചാർജ്: നിലവിലെ ബാറ്ററി ചാർജ് നില പ്രദർശിപ്പിക്കുന്നു.
- കണക്കാക്കിയ പ്രവർത്തന സമയം: Provides an estimate of how long the UPS can power connected devices during an outage.
- ഇൻപുട്ട്/ഔട്ട്പുട്ട് വോളിയംtage: Shows the current input and output voltage.
6. പരിപാലനം
6.1 ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ
The internal batteries are maintenance-free, sealed lead-acid. They are hot-swappable, meaning they can be replaced without shutting down connected equipment. However, for safety, it is recommended to disconnect the UPS from the main power source before replacement.
- Ensure the UPS is disconnected from the wall outlet.
- Locate the battery access panel, typically on the side or front of the unit.
- Remove any retaining screws or latches securing the panel.
- Carefully slide out the old battery pack. Note the orientation and connection points.
- Disconnect the battery cables (red and black) from the old battery.
- Connect the new battery cables to the new battery, ensuring correct polarity (red to red, black to black).
- Slide the new battery pack into the unit, ensuring it is securely seated.
- Replace the access panel and any retaining screws/latches.
- Reconnect the UPS to the wall outlet.
7. പ്രശ്നപരിഹാരം
7.1 യുപിഎസ് തുടർച്ചയായി ബീപ്പ് ചെയ്യുന്നു
- കാരണം: The battery may be disconnected or improperly installed.
- പരിഹാരം: Ensure the battery is correctly connected and seated. For new units, the battery might be shipped upside down or disconnected. Follow the battery installation steps in Section 6.1.
7.2 പവർ ഔട്ട്പുട്ട് ഇല്ല
- കാരണം: UPS is off, battery is depleted, or circuit breaker tripped.
- പരിഹാരം: Turn on the UPS. Check the battery charge level. Reset the circuit breaker on the back of the unit if it has tripped.
7.3 Short Run Time
- കാരണം: Overload, aging battery, or insufficient charge.
- പരിഹാരം: Reduce the connected load. Allow the battery to fully charge (up to 3 hours). If the battery is old, consider replacing it.
8 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| ഉൽപ്പന്ന അളവുകൾ | 33 x 24 x 10 ഇഞ്ച് |
| ഇനത്തിൻ്റെ ഭാരം | 140 പൗണ്ട് |
| നിർമ്മാതാവ് | SCHNEIDER ELECTRIC IT - CONTAINER |
| ഇനം മോഡൽ നമ്പർ | SMX120RMBP2U |
| ബാറ്ററികൾ ആവശ്യമാണ് | 1 ഉൽപ്പന്നത്തിന് പ്രത്യേക ബാറ്ററികൾ ആവശ്യമാണ്. |
| ബാറ്ററി സെൽ കോമ്പോസിഷൻ | ലെഡ് ആസിഡ് |
| വാല്യംtage | 120 വോൾട്ട് |
| നിറം | കറുപ്പ് |
| മെറ്റീരിയൽ | ലോഹം |
| Load Capacity (VA) | 1000 വി.എ |
| Load Capacity (Watt) | 800 W |
| റാക്ക് ഉയരം | 2U |
| പാത്രങ്ങൾ | 8 x NEMA 5-15R |
| Hot Swappable Batteries | അതെ |
| Maximum Battery Recharge Time | 3 മണിക്കൂർ |
9. വാറൻ്റിയും പിന്തുണയും
വാറന്റി വിവരങ്ങൾക്കും ഉപഭോക്തൃ പിന്തുണയ്ക്കും, ദയവായി ഔദ്യോഗിക ഷ്നൈഡർ ഇലക്ട്രിക് കാണുക. website or contact their customer service directly. You can also find additional support resources through the provided customer support link.