1. ആമുഖവും അവസാനവുംview
This manual provides essential instructions for the safe and effective use of your BriskHeat Full-Coverage Drum Heater, Model FGDHC55120D. This industrial-grade heater is designed for 55-gallon drums, offering solutions for viscosity control, freeze protection, temperature maintenance, and heating contents to a desired temperature. Its robust construction, high wattage, and efficient insulation ensure reliable performance.

Image 1: BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D) installed on a drum. This image illustrates the heater's full-coverage design and integrated control box.
2 സുരക്ഷാ വിവരങ്ങൾ
Read and understand all safety warnings and instructions before operating this drum heater. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- ഇലക്ട്രിക്കൽ സുരക്ഷ: Ensure the power source matches the heater's voltage (120 Volts). Do not operate with damaged cords or plugs. Always connect to a grounded outlet.
- കത്തുന്ന വസ്തുക്കൾ: Do not use this heater with drums containing highly flammable liquids or in environments with explosive atmospheres unless specifically rated for such use. Consult material safety data sheets (MSDS) for contents.
- അമിത ചൂടാക്കൽ: Do not cover the heater's control unit or restrict airflow around the drum. Monitor the temperature to prevent overheating of drum contents.
- പ്ലേസ്മെൻ്റ്: Ensure the drum and heater are placed on a stable, non-combustible surface. The heater is designed for floor mount applications.
- പരിപാലനം: ഏതെങ്കിലും അറ്റകുറ്റപ്പണികൾ അല്ലെങ്കിൽ വൃത്തിയാക്കൽ നടത്തുന്നതിന് മുമ്പ് വൈദ്യുതി വിച്ഛേദിക്കുക.
3. പാക്കേജ് ഉള്ളടക്കം
പായ്ക്ക് അൺപാക്ക് ചെയ്യുമ്പോൾ എല്ലാ ഇനങ്ങളും ഉണ്ടെന്ന് ഉറപ്പാക്കുക:
- 1 x BriskHeat Full-Coverage Drum Heater (Model FGDHC55120D)
- നിർദ്ദേശ മാനുവൽ (ഈ പ്രമാണം)
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
The BriskHeat Full-Coverage Drum Heater is designed for easy installation on standard 55-gallon drums.
- ഡ്രം തയ്യാറാക്കുക: Ensure the 55-gallon drum is clean, dry, and free from any sharp edges that could damage the heater's fabric.
- ഹീറ്റർ സ്ഥാപിക്കുക: Carefully wrap the heater around the drum, ensuring it covers the drum's circumference evenly. The heater is designed for floor mount applications, so ensure the drum is on a stable surface.
- ഹീറ്റർ സുരക്ഷിതമാക്കുക: Use the integrated fastening system (e.g., straps or buckles) to secure the heater snugly around the drum. Ensure there are no gaps or loose areas that could compromise heating efficiency.
- പവർ ബന്ധിപ്പിക്കുക: Plug the heater's power cord into a grounded 120 Volt electrical outlet. Ensure the outlet can handle the heater's 1600 Watts power consumption.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The BriskHeat drum heater features an integrated control system for temperature management.
- പവർ ഓൺ: Once plugged in, the heater is ready for operation. The control unit will typically display the current temperature or be ready for programming.
- താപനില സജ്ജമാക്കുക: Use the controls on the integrated unit to set the desired temperature for the drum contents. Refer to the specific instructions on the control unit for detailed programming steps.
- മോണിറ്റർ പ്രവർത്തനം: The heater will begin to warm the drum contents. Periodically monitor the temperature and the heater's operation to ensure it is functioning as expected.
- പവർ ഓഫ്: To turn off the heater, either unplug it from the power source or use the power control on the integrated unit, if available.

ചിത്രം 2: ക്ലോസ്-അപ്പ് view of the control box on the BriskHeat Full-Coverage Drum Heater. This box houses the temperature controls and power connection.
6. പരിപാലനം
Proper maintenance ensures the longevity and safe operation of your drum heater.
- വൃത്തിയാക്കൽ: Disconnect power before cleaning. Wipe the exterior of the heater with a damp cloth. Do not immerse the heater in water or use abrasive cleaners.
- പരിശോധന: Regularly inspect the heater for any signs of wear, tear, cuts, or damage to the fabric, power cord, or control unit. Do not operate a damaged heater.
- സംഭരണം: When not in use, store the heater in a clean, dry place, away from direct sunlight and extreme temperatures. Ensure it is properly coiled or folded to prevent damage to internal heating elements.
7. പ്രശ്നപരിഹാരം
If you encounter issues with your BriskHeat drum heater, refer to the following common troubleshooting steps:
- ഹീറ്റർ ഓണാക്കുന്നില്ല:
- പവർ കോർഡ് ഒരു ലൈവ് 120V ഔട്ട്ലെറ്റിൽ സുരക്ഷിതമായി പ്ലഗ് ചെയ്തിട്ടുണ്ടോയെന്ന് പരിശോധിക്കുക.
- Verify that the circuit breaker or fuse for the outlet has not tripped.
- ദൃശ്യമായ എന്തെങ്കിലും കേടുപാടുകൾ ഉണ്ടോയെന്ന് പവർ കോർഡ് പരിശോധിക്കുക.
- Heater Not Reaching Desired Temperature:
- Ensure the temperature setting on the control unit is correct.
- Verify the heater is snugly fitted around the drum to minimize heat loss.
- Check for drafts or cold ambient temperatures that may affect heating efficiency.
- Ensure the drum contents are not excessively cold or require a longer heating time.
- അസാധാരണമായ ദുർഗന്ധം അല്ലെങ്കിൽ പുക: Immediately disconnect power and cease operation. Contact BriskHeat customer support.
8 സ്പെസിഫിക്കേഷനുകൾ
| ആട്രിബ്യൂട്ട് | വിശദാംശങ്ങൾ |
|---|---|
| നിർമ്മാതാവ് | ബ്രിസ്ക്ഹീറ്റ് |
| ഭാഗം നമ്പർ | 2950106 |
| ഇനത്തിൻ്റെ ഭാരം | 25 പൗണ്ട് |
| ഇനം മോഡൽ നമ്പർ | FGDHC55120D |
| വലിപ്പം | Large (for 55-gallon drums) |
| പവർ ഉറവിടം | കോർഡഡ് ഇലക്ട്രിക് |
| വാല്യംtage | 120 വോൾട്ട് |
| വാട്ട്tage | 1600 വാട്ട്സ് |
| ഇനത്തിൻ്റെ പാക്കേജ് അളവ് | 1 |
| മൗണ്ടിംഗ് തരം | ഫ്ലോർ മൗണ്ട് |
| ASIN | B00GE9LSO8 |
| ആദ്യ തീയതി ലഭ്യമാണ് | ഏപ്രിൽ 30, 2015 |
9. വാറൻ്റിയും പിന്തുണയും
For warranty information, technical support, or service inquiries, please contact BriskHeat directly. Keep your purchase receipt and model number (FGDHC55120D) handy when contacting support.
BriskHeat Contact Information:
Please refer to the official BriskHeat webഏറ്റവും പുതിയ കോൺടാക്റ്റ് വിശദാംശങ്ങൾക്കായി സൈറ്റ് അല്ലെങ്കിൽ ഉൽപ്പന്ന പാക്കേജിംഗ്.