VOLTCRAFT VC-55 LCD

VOLTCRAFT VC-55 LCD 2-Pole Voltagഇ ടെസ്റ്റർ ഇൻസ്ട്രക്ഷൻ മാനുവൽ

Brand: VOLTCRAFT | Model: VC-55 LCD

1. ആമുഖം

This manual provides essential information for the safe and effective use of your VOLTCRAFT VC-55 LCD 2-Pole Voltage Tester. This device is designed for reliable voltage testing, continuity checks, unipolar phase testing, and rotating field testing. It features both an LCD and LED display for clear readings and is built to meet EN 61243-3 and VDE0682 standards, ensuring high safety and performance.

2 സുരക്ഷാ വിവരങ്ങൾ

WARNING: Electrical testing can be hazardous. Always follow safety precautions to prevent injury or damage.

  • Always inspect the tester for damage before use. Do not use if the housing, test leads, or probes are damaged.
  • Ensure the device is rated for the voltage and current levels you intend to measure. This tester is rated CAT III 1000 V and CAT IV 600 V.
  • Never touch live conductors with bare hands. Use appropriate personal protective equipment (PPE).
  • Do not use the tester in wet conditions or in explosive atmospheres.
  • Verify the tester's functionality on a known live source before and after each use.
  • If you are unsure about any procedure, consult a qualified electrician.

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

പ്രധാന സവിശേഷതകൾ

  • CAT III 1000 V, CAT IV 600 V സുരക്ഷാ റേറ്റിംഗ്
  • LCD and LED voltage display (12 V to 690 V)
  • Continuity test with acoustic and visual indication
  • Unipolar phase test
  • Rotating field test
  • Integrated measurement point illumination (flashlight)
VOLTCRAFT VC-55 LCD 2-Pole Voltagഇ ടെസ്റ്റർ

Figure 1: The VOLTCRAFT VC-55 LCD 2-Pole Voltage Tester, showing its main body, test leads, and display.

4. സജ്ജീകരണം

4.1 ബാറ്ററി ഇൻസ്റ്റാളേഷൻ

The VC-55 LCD requires 2 AAA batteries (included) for operation. To install or replace batteries:

  1. ഉപകരണത്തിന്റെ പിൻഭാഗത്ത് ബാറ്ററി കമ്പാർട്ട്മെന്റ് കവർ കണ്ടെത്തുക.
  2. Use a suitable tool (e.g., a small screwdriver) to open the cover.
  3. ശരിയായ പോളാരിറ്റി (+/-) ഉറപ്പാക്കിക്കൊണ്ട് 2 AAA ബാറ്ററികൾ ഇടുക.
  4. ബാറ്ററി കമ്പാർട്ട്മെന്റ് കവർ സുരക്ഷിതമായി അടയ്‌ക്കുക.

4.2 Probe Preparation

The test probes come with protective caps and interchangeable tips. For most applications, the standard tips are suitable. For testing in sockets with child protection, screw-on round tips are provided.

Close-up of VOLTCRAFT VC-55 LCD probes and interchangeable tips

ചിത്രം 2: ക്ലോസപ്പ് view of the test probes and the included interchangeable tips for various testing scenarios.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1 വോളിയംtagഇ മെഷർമെന്റ് (എസി/ഡിസി)

വോളിയം അളക്കാൻtage:

  1. Connect both test probes to the circuit or component you wish to measure.
  2. വോളിയംtage value will be displayed on the LCD screen.
  3. Corresponding LEDs will illuminate to indicate the voltage range (12V, 24V, 50V, 120V, 230V, 400V, 690V).
  4. The device automatically detects AC or DC voltage.
VOLTCRAFT VC-55 LCD in use measuring voltagഒരു ഇലക്ട്രിക്കൽ പാനലിലെ ഇ

Figure 3: The VC-55 LCD tester actively measuring voltage within an electrical control panel, displaying readings on its screen.

5.2 തുടർച്ച പരിശോധന

ഒരു തുടർച്ച പരിശോധന നടത്താൻ:

  1. Ensure the circuit is de-energized before testing for continuity.
  2. Touch the two test probes to the ends of the circuit or component you want to test.
  3. If continuity exists (low resistance), an acoustic signal will sound, and a dedicated LED will illuminate.

5.3 Unipolar Phase Test

To test for phase (live wire) in AC circuits:

  1. Hold the main body of the tester firmly.
  2. Touch only one test probe to the conductor you suspect is live.
  3. If the conductor is live, the phase indicator (usually an 'R' or similar symbol) on the display will light up.

5.4 Rotating Field Test

To determine the phase sequence in three-phase systems:

  1. Connect the test probes to two phases of the three-phase system.
  2. The tester will indicate the direction of the rotating field (e.g., 'L' for left, 'R' for right, or arrows).
VOLTCRAFT VC-55 LCD in use testing a wall socket

Figure 4: The VC-55 LCD tester being used to safely check the voltage and presence of live wires in a standard wall socket.

6. പരിപാലനം

  • വൃത്തിയാക്കൽ: Clean the device regularly with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
  • സംഭരണം: Store the tester in a dry, cool place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
  • ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ: Replace batteries when the low battery indicator appears on the LCD.

7. പ്രശ്‌നപരിഹാരം

  • ഡിസ്പ്ലേ ഇല്ല/പവർ ഇല്ല: ബാറ്ററി ഇൻസ്റ്റാളേഷൻ പരിശോധിച്ച് ബാറ്ററികൾ തീർന്നിട്ടില്ലെന്ന് ഉറപ്പാക്കുക. ആവശ്യമെങ്കിൽ മാറ്റിസ്ഥാപിക്കുക.
  • കൃത്യമല്ലാത്ത വായനകൾ: Ensure probes are making good contact with the test points. Verify the tester on a known voltagഇ ഉറവിടം.
  • No Continuity Indication: സർക്യൂട്ട് ഡീ-എനർജൈസ്ഡ് ആണെന്ന് ഉറപ്പാക്കുക. തുറന്ന സർക്യൂട്ടുകൾ അല്ലെങ്കിൽ ഉയർന്ന പ്രതിരോധം പരിശോധിക്കുക.
  • Tester Not Responding: Remove batteries, wait a few seconds, and reinsert them. If the issue persists, contact customer support.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്വോൾട്രാഫ്റ്റ്
മോഡൽ നമ്പർVC-55 LCD
അളക്കൽ തരം2-Pole Voltagഇ ടെസ്റ്റർ
സുരക്ഷാ റേറ്റിംഗ്CAT III 1000V, CAT IV 600V
വാല്യംtagഇ ഡിസ്പ്ലേLCD and LED (12 V to 690 V)
അനുയോജ്യമായ സ്പെസിഫിക്കേഷനുകൾEN 61243-3/VDE0682
പവർ ഉറവിടംBattery Powered (2 AAA - included)
മിനി. പ്രവർത്തന വോളിയംtage12 വോൾട്ട്
Max. Rated Temperature71 ഡിഗ്രി സെൽഷ്യസ്
നിറംകറുപ്പും വെളുപ്പും
ഇനത്തിൻ്റെ അളവുകൾ30.7 x 19 x 4.2 സെ.മീ
ഇനത്തിൻ്റെ ഭാരം9.07 ഗ്രാം
സ്പെയർ പാർട്സ് ലഭ്യത1 വർഷം

9. വാറൻ്റിയും പിന്തുണയും

This VOLTCRAFT product is designed for durability and reliability. For information regarding warranty coverage, spare parts availability, or technical support, please refer to the documentation included with your purchase or visit the official VOLTCRAFT website. For specific inquiries, you may also contact the seller directly.

അനുബന്ധ രേഖകൾ - VC-55 LCD

പ്രീview VOLTCRAFT VC292 Digitalmultimeter Bedienungsanleitung und Technische Daten
Umfassende Bedienungsanleitung für das VOLTCRAFT VC292 Digitalmultimeter und den Stromzangenwandler CLA60, inklusive Sicherheitshinweisen, Messanleitungen und technischen Spezifikationen.
പ്രീview VOLTCRAFT ഡിജിറ്റൽ മൾട്ടിമീറ്ററുകൾ VC-7060BT & VC-7200BT ഉപയോക്തൃ മാനുവൽ
VOLTCRAFT VC-7060BT, VC-7200BT ഡിജിറ്റൽ മൾട്ടിമീറ്ററുകൾക്കായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, സുരക്ഷ, പ്രവർത്തനം, പ്രവർത്തനങ്ങൾ, അളക്കൽ ട്യൂട്ടോറിയലുകൾ, ട്രബിൾഷൂട്ടിംഗ്, സാങ്കേതിക സവിശേഷതകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview VOLTCRAFT VC-7060BT & VC-7200BT ഡിജിറ്റൽ മൾട്ടിമീറ്റർ ക്വിക്ക് ഗൈഡ്
VOLTCRAFT VC-7060BT, VC-7200BT ഡിജിറ്റൽ മൾട്ടിമീറ്ററുകൾക്കായുള്ള സമഗ്രമായ ക്വിക്ക് ഗൈഡ്. സുരക്ഷ, പ്രവർത്തനം, അളവുകൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവയെക്കുറിച്ച് അറിയുക.
പ്രീview VOLTCRAFT VC891 Multimetro Digitale: Istruzioni per l'uso e Specifiche Tecniche
Manuale d'uso completo per il multimetro digitale VOLTCRAFT VC891. Include istruzioni dettagliate su utilizzo, misurazioni, funzioni aggiuntive, manutenzione e specifiche tecniche. Ideale per professionisti e hobbisti.
പ്രീview VOLTCRAFT VC-BT300PRO OBDII + Batterietester Bedienungsanleitung
Umfassende Bedienungsanleitung für den VOLTCRAFT VC-BT300PRO, ein Diagnosewerkzeug für OBD-II und Batterietests. Enthält Funktionen, Sicherheitshinweise und technische Daten.
പ്രീview VOLTCRAFT MT-52 5-in-1 Digital Multimeter User Manual
This document provides comprehensive operating instructions, safety guidelines, and technical specifications for the VOLTCRAFT MT-52 5-in-1 Digital Multimeter. Learn how to measure voltage, current, resistance, temperature, humidity, light, and sound levels.