Everbilt UT00801

എവർബിൽറ്റ് 1/6 എച്ച്പി സബ്‌മെഴ്‌സിബിൾ യൂട്ടിലിറ്റി പമ്പ് ഇൻസ്ട്രക്ഷൻ മാനുവൽ

1. ആമുഖം

The Everbilt 1/6 HP Submersible Utility Pump (Model UT00801) is engineered for efficient water removal from various locations. This pump is ideal for draining sinks, tubs, and shallow flooded areas such as basements, floors, and flat roofs. Its submersible design allows it to operate directly in water, effectively reducing water levels down to 1/8 inch.

This manual provides essential information for the safe and effective use of your Everbilt utility pump. Please read all instructions carefully before installation and operation.

Everbilt 1/6 HP Submersible Utility Pump

ചിത്രം 1: Everbilt 1/6 HP Submersible Utility Pump. This image displays the main unit of the pump, highlighting its compact, black plastic housing, the threaded discharge port, and the power cord connection point. A separate threaded adapter is also visible.

2 സുരക്ഷാ വിവരങ്ങൾ

Always prioritize safety when operating electrical equipment, especially near water. Failure to follow these safety guidelines can result in electric shock, fire, personal injury, or property damage.

  • ഇലക്ട്രിക്കൽ സുരക്ഷ: Ensure the pump is connected to a properly grounded outlet. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and wet conditions. Never operate the pump with damaged cords or plugs.
  • സബ്‌മേഴ്‌സിബിൾ ഉപയോഗം മാത്രം: This pump is designed for submersible operation. Do not run the pump dry, as this can cause severe damage to the motor.
  • ജലത്തിൻ്റെ താപനില: Do not use this pump with water temperatures exceeding 104°F (40°C).
  • കത്തുന്ന ദ്രാവകങ്ങൾ: Never pump flammable or corrosive liquids. This pump is intended for water only.
  • കുട്ടികളും വളർത്തുമൃഗങ്ങളും: Keep children and pets away from the pump and any standing water during operation.
  • പരിപാലനം: Always disconnect power before performing any maintenance or cleaning on the pump.

3. പാക്കേജ് ഉള്ളടക്കം

അൺപാക്ക് ചെയ്യുമ്പോൾ എല്ലാ ഘടകങ്ങളും ഉണ്ടെന്നും കേടുപാടുകൾ സംഭവിച്ചിട്ടില്ലെന്നും ഉറപ്പാക്കുക.

  • Everbilt 1/6 HP Submersible Utility Pump (Model UT00801)
  • Threaded Hose Adapter
  • ഇൻസ്ട്രക്ഷൻ മാനുവൽ

4. സജ്ജീകരണം

  1. ഡിസ്ചാർജ് ഹോസ് ഘടിപ്പിക്കുക: Connect a standard garden hose or a suitable discharge pipe to the pump's threaded outlet. The pump includes a removable adapter to accommodate different hose sizes. Ensure a secure, leak-free connection.
  2. പമ്പ് സ്ഥാപിക്കുക: Place the pump on a stable, level surface in the area to be drained. Ensure the intake screen at the bottom of the pump is clear of debris. The pump must be fully submerged in water for proper operation and cooling.
  3. Route Discharge Hose: Extend the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained. Avoid kinks or sharp bends in the hose that could restrict water flow.
  4. പവർ കണക്ഷൻ: Plug the pump's power cord into a grounded 120V AC electrical outlet. The pump will begin operating immediately upon connection to power.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The Everbilt 1/6 HP Submersible Utility Pump is designed for continuous operation once plugged in, provided it remains submerged.

  • യാന്ത്രിക പ്രവർത്തനം: This model operates continuously when plugged in. There is no on/off switch on the unit itself. Operation starts when power is supplied and stops when power is disconnected.
  • ജലനിരപ്പ്: The pump is capable of removing water down to a minimum level of approximately 1/8 inch. For optimal performance, ensure the pump remains submerged during operation.
  • നിരീക്ഷണം: Periodically check the pump's operation and the discharge area to ensure proper water flow and prevent accidental flooding.
  • വിച്ഛേദിക്കൽ: പമ്പ് നിർത്താൻ, ഇലക്ട്രിക്കൽ ഔട്ട്ലെറ്റിൽ നിന്ന് അത് അൺപ്ലഗ് ചെയ്യുക.

6. പരിപാലനം

Regular maintenance ensures the longevity and efficient performance of your pump.

  • Cleaning Intake Screen: Regularly inspect and clean the intake screen at the bottom of the pump to prevent blockages from debris, which can reduce pumping efficiency.
  • സംഭരണം: When not in use, clean the pump thoroughly and store it in a dry, frost-free location. Drain any remaining water from the pump and hose to prevent freezing damage.
  • പരിശോധന: Before each use, inspect the power cord, plug, and pump housing for any signs of damage. Do not use the pump if any damage is observed.

7. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പമ്പ് ആരംഭിക്കുന്നില്ലNo power; tripped circuit breaker; damaged cord/plugCheck power supply; reset breaker; inspect and replace damaged components.
പമ്പ് ഓടുന്നു, പക്ഷേ വെള്ളം പമ്പ് ചെയ്യുന്നില്ലIntake screen clogged; air lock; discharge hose kinked/blocked; pump not submergedClean intake screen; prime pump by submerging fully; clear hose; ensure pump is fully submerged.
ജലപ്രവാഹം കുറഞ്ഞുPartial blockage in intake or hose; low voltageClean intake screen and hose; ensure stable power supply.
പമ്പ് വേഗത്തിൽ ഓണും ഓഫും ആക്കുന്നുInsufficient water level; air in systemEnsure adequate water level for continuous operation; check for air leaks in connections.

If troubleshooting steps do not resolve the issue, contact Everbilt customer support for assistance.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
ബ്രാൻഡ്എവർബിൽറ്റ്
മോഡൽ നമ്പർUT00801
കുതിരശക്തി1 / 6 HP
ഫ്ലോ റേറ്റ്Up to 28 Gallons Per Minute (GPM)
പരമാവധി ലിഫ്റ്റിംഗ് ഉയരം0.13 Inches (Note: This value likely refers to the minimum water level the pump can achieve, not its maximum lift height.)
ഏറ്റവും കുറഞ്ഞ ജലനിരപ്പ്1/8 inch (approx.)
ഇനത്തിൻ്റെ ഭാരം5.71 പൗണ്ട്
ഉൽപ്പന്ന അളവുകൾ7.68 x 6.89 x 10.63 ഇഞ്ച്
പവർ ഉറവിടംAC/DC (Standard 120V AC for typical use)
മെറ്റീരിയൽപ്ലാസ്റ്റിക്
ശൈലിമുങ്ങിപ്പോകാവുന്ന

9. വാറൻ്റിയും പിന്തുണയും

The Everbilt 1/6 HP Submersible Utility Pump comes with a 1-വർഷ പരിമിത വാറൻ്റി. For warranty claims, technical support, or replacement parts, please contact Everbilt customer service directly. Keep your purchase receipt as proof of purchase.

For further assistance, refer to the official Everbilt webസൈറ്റ് അല്ലെങ്കിൽ അവരുടെ ഉപഭോക്തൃ പിന്തുണാ ലൈനുമായി ബന്ധപ്പെടുക.

അനുബന്ധ രേഖകൾ - UT00801

പ്രീview എവർബിൽറ്റ് സബ്‌മേഴ്‌സിബിൾ സംപ് പമ്പ് ഉപയോഗവും പരിചരണ ഗൈഡും
എവർബിൽറ്റ് സബ്‌മെർസിബിൾ സംപ് പമ്പുകളുടെ സുരക്ഷിതവും ഫലപ്രദവുമായ ഉപയോഗത്തിനും പരിപാലനത്തിനുമുള്ള അവശ്യ വിവരങ്ങൾ ഈ ഗൈഡ് നൽകുന്നു. SP03302VD, SP05002VD, PSSP07501VD, PSSP10001VD എന്നിവയുൾപ്പെടെയുള്ള മോഡലുകളുടെ പ്രകടന സവിശേഷതകൾ, സുരക്ഷാ മുൻകരുതലുകൾ, ഇൻസ്റ്റാളേഷൻ ഘട്ടങ്ങൾ, പ്രവർത്തനം, പരിപാലനം, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview Everbilt Submersible Sump Pump Use and Care Guide | SP03302EP, SP05002VD
This comprehensive guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models SP03302EP and SP05002VD. Learn about performance specifications, assembly, operation, troubleshooting, and warranty details.
പ്രീview എവർബിൽറ്റ് സബ്‌മേഴ്‌സിബിൾ സംപ് പമ്പ് ഉപയോഗവും പരിചരണ ഗൈഡും (PSSP10001EP, PSSP07501VD)
എവർബിൽറ്റ് സബ്‌മെർസിബിൾ സംപ് പമ്പുകളുടെ സുരക്ഷിതവും ഫലപ്രദവുമായ ഉപയോഗം, പരിചരണം, പരിപാലനം എന്നിവയ്ക്കുള്ള അവശ്യ വിവരങ്ങൾ ഈ ഗൈഡ് നൽകുന്നു, മോഡലുകൾ PSSP10001EP, PSSP07501VD. ഇതിൽ സ്പെസിഫിക്കേഷനുകൾ, അസംബ്ലി നിർദ്ദേശങ്ങൾ, പ്രവർത്തന വിശദാംശങ്ങൾ, ട്രബിൾഷൂട്ടിംഗ് നുറുങ്ങുകൾ എന്നിവ ഉൾപ്പെടുന്നു.
പ്രീview എവർബിൽറ്റ് സബ്‌മേഴ്‌സിബിൾ സംപ് പമ്പ് ഉപയോഗവും പരിചരണ ഗൈഡും
Comprehensive use and care guide for Everbilt submersible sump pumps (models SP03302EP, SP05002VD), covering installation, operation, safety, and troubleshooting.
പ്രീview എവർബിൽറ്റ് സബ്‌മേഴ്‌സിബിൾ സംപ് പമ്പ് ഉപയോഗവും പരിചരണ ഗൈഡും | SBA025BC, SBA033BC, SBA033V1, SBA050BC
SBA025BC, SBA033BC, SBA033V1, SBA050BC മോഡലുകളുടെ ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, സുരക്ഷാ വിവരങ്ങൾ, അറ്റകുറ്റപ്പണി, ട്രബിൾഷൂട്ടിംഗ് എന്നിവയുൾപ്പെടെ എവർബിൽറ്റ് സബ്‌മെർസിബിൾ സംപ് പമ്പുകളുടെ സമഗ്രമായ ഉപയോഗ, പരിചരണ ഗൈഡ്. ബന്ധപ്പെടാനുള്ള വിവരങ്ങളും സവിശേഷതകളും കണ്ടെത്തുക.
പ്രീview Everbilt Submersible Sump Pump Use and Care Guide (Model ECD50V-HDC)
This guide provides essential information for the safe installation, operation, maintenance, and troubleshooting of the Everbilt Submersible Sump Pump, Model ECD50V-HDC. Learn about safety precautions, performance specifications, and common issues to ensure optimal pump performance.