ആമുഖം
This instruction manual provides essential information for the proper installation, operation, and maintenance of your SoClean Adapter for ResMed AirSense 10 and AirCurve 10 Series CPAP Machines. The adapter is designed to ensure seamless compatibility between your ResMed CPAP machine's humidifier chamber and your SoClean CPAP Cleaner and Sanitizer system, allowing for effective cleaning without compromising the functionality of your CPAP therapy.
ഉൽപ്പന്നം കഴിഞ്ഞുview
The SoClean Adapter is a specialized lid that replaces the standard lid on the humidifier chamber of ResMed AirSense 10 and AirCurve 10 Series CPAP machines. It features a dedicated port for connecting the SoClean unit's injection hose, facilitating the cleaning process. This adapter is compatible with all SoClean models and is crucial for maintaining the integrity of your CPAP system while using the SoClean cleaner.

Image: The SoClean Adapter for ResMed AirSense 10 and AirCurve 10 Series CPAP Machines. This adapter replaces the standard humidifier chamber lid to allow connection to a SoClean cleaning device.
പാക്കേജ് ഉള്ളടക്കം
- 1 x SoClean Adapter for ResMed AirSense 10 and AirCurve 10 Series CPAP Machines
പ്രധാന കുറിപ്പ്:
The original gasket/seal from your ResMed humidifier chamber lid is required for use with this adapter. It is not included with the SoClean Adapter.
സജ്ജീകരണ നിർദ്ദേശങ്ങൾ
Follow these steps to properly install the SoClean Adapter onto your ResMed AirSense 10 or AirCurve 10 CPAP machine's humidifier chamber:
- Prepare the Humidifier Chamber: Ensure your ResMed CPAP machine is turned off and unplugged. Remove the humidifier chamber from your CPAP machine.
- Remove Original Lid: Carefully open and detach the original lid from your ResMed humidifier chamber.
- Transfer Gasket: Locate the silicone gasket or seal inside the original lid. Gently remove this gasket. This component is essential for a proper seal and must be transferred to the SoClean Adapter.
- Install Gasket into Adapter: Place the transferred gasket securely into the designated groove within the SoClean Adapter lid. Ensure it is seated correctly and evenly to prevent leaks.
- Attach Adapter to Chamber: Position the SoClean Adapter lid onto the humidifier chamber, ensuring it clicks firmly into place. Verify that the lid is fully closed and sealed.
- Connect to SoClean Unit: Connect the injection hose from your SoClean CPAP Cleaner and Sanitizer unit to the port on the newly installed SoClean Adapter lid. Ensure a snug connection.
- Reinsert Chamber: Place the humidifier chamber with the installed adapter back into your ResMed CPAP machine.
Your ResMed CPAP machine is now ready for use with the SoClean system.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once the SoClean Adapter is installed, the operation of your ResMed CPAP machine and SoClean cleaner will proceed as follows:
- ദിവസേനയുള്ള വെള്ളം നിറയ്ക്കൽ: To refill the humidifier chamber with water, remove the chamber from the CPAP machine. You do not need to remove the SoClean Adapter lid. Simply open the small access flap on the adapter lid, fill the chamber with distilled water, and close the flap securely. Reinsert the chamber into the CPAP machine.
- CPAP Machine Operation: Operate your ResMed CPAP machine as you normally would. The adapter does not interfere with the CPAP machine's therapeutic function.
- SoClean Operation: Follow the instructions provided with your SoClean CPAP Cleaner and Sanitizer for its operation. The adapter facilitates the delivery of the cleaning agent into the humidifier chamber and CPAP system.
മെയിൻ്റനൻസ്
Proper maintenance of your SoClean Adapter ensures its longevity and continued performance:
- Cleaning the Adapter: Periodically wipe the exterior of the adapter with a damp cloth. Do not submerge the adapter in water or use harsh chemical cleaners, as this may damage the material or affect its sealing properties.
- ഗാസ്കറ്റ് പരിശോധന: Regularly inspect the silicone gasket for any signs of wear, cracking, or damage. A compromised gasket can lead to air leaks. If the gasket is damaged, it may need to be replaced. Refer to your ResMed CPAP machine's manual for information on obtaining replacement gaskets, as they are typically part of the original humidifier chamber.
- കണക്ഷൻ പരിശോധന: Ensure the connection between the SoClean hose and the adapter port remains secure and free of debris.
ട്രബിൾഷൂട്ടിംഗ്
If you encounter issues while using the SoClean Adapter, consider the following:
- Air Leaks from Humidifier Chamber:
- Ensure the silicone gasket is correctly seated within the adapter lid.
- Verify that the adapter lid is securely closed and latched onto the humidifier chamber.
- Inspect the gasket for any damage or wear that might prevent a proper seal.
- SoClean Unit Not Functioning Correctly:
- Check that the SoClean injection hose is firmly connected to the adapter port.
- Refer to your SoClean unit's instruction manual for specific troubleshooting steps related to the cleaner itself.
- CPAP Machine Performance Issues:
- Ensure the humidifier chamber with the adapter is correctly inserted into the CPAP machine.
- Verify that no parts of the adapter are obstructing airflow within the CPAP system.
- If issues persist, remove the adapter and re-test your CPAP machine with its original humidifier lid to isolate the problem.
For further assistance, consult the user manuals for your ResMed CPAP machine and SoClean cleaner, or contact SoClean customer support.
സ്പെസിഫിക്കേഷനുകൾ
| മോഡൽ നമ്പർ | PNA1210 |
| ഉൽപ്പന്ന അളവുകൾ | 8 x 6 x 8 ഇഞ്ച്; 6.74 ഔൺസ് |
| അനുയോജ്യത | ResMed AirSense 10 Series CPAP Machines, ResMed AirCurve 10 Series CPAP Machines, All SoClean models |
| നിർമ്മാതാവ് | SoClean |
വാറൻ്റിയും പിന്തുണയും
For information regarding product warranty, returns, or technical support, please contact SoClean customer service directly. Specific warranty terms and conditions may vary and are typically provided with your purchase documentation or available on the official SoClean webസൈറ്റ്.