1. ആമുഖം
This manual provides essential information for the safe and effective use of the Greisinger GMH 3451 Conductivity Meter. This device is designed for precise measurement of conductivity, specific resistance, salinity, Total Dissolved Solids (TDS), and temperature. It features a robust design with an integrated 4-pole measuring cell and a data logger for comprehensive analysis.

ചിത്രം 1: മുൻഭാഗം view of the Greisinger GMH 3451 Conductivity Meter.
2. ഉൽപ്പന്ന സവിശേഷതകൾ
The Greisinger GMH 3451 offers a range of features for accurate and convenient measurements:
- അളക്കൽ പ്രവർത്തനങ്ങൾ: Conductivity, specific resistance, salinity, TDS, and temperature.
- Integrated Measuring Cell: 4-pole measuring cell with graphite electrode and epoxy shaft, fixed to the device with approximately 1 meter of cable.
- ഡാറ്റ ലോഗർ: Built-in data logging capabilities for recording measurement values.
- Automatic OFF Function: ബാറ്ററി ലൈഫ് സംരക്ഷിക്കുന്നു.
- ഹോൾഡ് പ്രവർത്തനം: Freezes the current measurement display.
- MIN/MAX Memory: Stores minimum and maximum measured values.
- അലാറം പ്രവർത്തനം: Configurable minimum and maximum alarms.
- തത്സമയ ക്ലോക്ക്: For accurate time-stamping of logged data.
- Cell Correction: 0.800 മുതൽ 1200 സെൻ്റീമീറ്റർ വരെ ക്രമീകരിക്കാവുന്നതാണ്-1, manually or automatically via selectable reference solutions.
- താപനില നഷ്ടപരിഹാരം: Deactivatable, with non-linear, linear, or no compensation options.
- ഇൻ്റർഫേസ്: Serial interface for data transfer.
- വൈദ്യുതി വിതരണം: Operates with batteries (replacement message available) and supports an external power adapter.
- സംരക്ഷണ തരം: IP65, offering protection against dust and low-pressure water jets.

Figure 2: Greisinger GMH 3451 Conductivity Meter showing the attached electrode.
3. സജ്ജീകരണം
- അൺപാക്ക് ചെയ്യുന്നു: Carefully remove the device and all accessories from the packaging. Inspect for any visible damage.
- വൈദ്യുതി വിതരണം: The device can be powered by batteries or an external power adapter. If using batteries, ensure they are correctly inserted. The device will display a message when battery replacement is needed.
- ഇലക്ട്രോഡ് കണക്ഷൻ: The 4-pole measuring cell is permanently connected to the device via a 1-meter cable. Ensure the cable is not damaged or kinked.
- പ്രാരംഭ പവർ ഓൺ: Press the power button to turn on the device. The display should illuminate.
- അടിസ്ഥാന ക്രമീകരണങ്ങൾ: Refer to the operating instructions for initial configuration, such as setting the real-time clock and preferred measurement units.
4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
കൃത്യമായ അളവുകൾക്കായി ഈ ഘട്ടങ്ങൾ പാലിക്കുക:
- പവർ ഓൺ: അമർത്തുക ഓൺ/ഓഫ് ഉപകരണം ഓണാക്കാനുള്ള ബട്ടൺ.
- അളക്കൽ മോഡ് തിരഞ്ഞെടുക്കുക: Use the mode selection buttons (if available, not explicitly detailed in source but implied by multiple functions) to choose between conductivity, specific resistance, salinity, TDS, or temperature measurement.
- Calibration (Cell Correction):
- For accurate readings, perform cell correction regularly.
- The cell constant can be adjusted manually (0.800 - 1200 cm-1) or automatically using selectable reference solutions. Consult the device's on-screen menu for calibration procedures.
- താപനില നഷ്ടപരിഹാരം: Ensure the appropriate temperature compensation setting is selected (non-linear, linear, or none) based on your application. This function can be deactivated if not required.
- ഒരു അളവ് എടുക്കൽ: ഇലക്ട്രോഡ് s-ൽ മുക്കുക.ample solution. Ensure the electrode is fully submerged and free of air bubbles. Wait for the reading to stabilize on the digital display.
- ഹോൾഡ് പ്രവർത്തനം: അമർത്തുക പിടിക്കുക button to freeze the current display value. Press again to release.
- MIN/MAX Values: Access the MIN/MAX memory function to view the lowest and highest recorded values during a measurement session.
- ഡാറ്റ ലോഗിംഗ്: Utilize the data logger function to record measurements over time. Refer to the device's menu for setting logging intervals and retrieving data via the serial interface.
- പവർ ഓഫ്: അമർത്തിപ്പിടിക്കുക ഓൺ/ഓഫ് button to switch off the device. The automatic OFF function will also power down the device after a period of inactivity.
5. പരിപാലനം
Proper maintenance ensures the longevity and accuracy of your Greisinger GMH 3451:
- ഇലക്ട്രോഡ് ക്ലീനിംഗ്: After each use, rinse the graphite electrode and epoxy shaft with distilled or deionized water to prevent residue buildup. For stubborn deposits, use a soft brush or a mild cleaning solution recommended by the manufacturer.
- ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ: When the low battery indicator appears, replace the batteries promptly. Ensure the device is off before opening the battery compartment. Dispose of old batteries according to local regulations.
- സംഭരണം: Store the device in a clean, dry place at temperatures within the specified operating range (-5 to +80 °C). Protect the electrode from physical damage.
- കാലിബ്രേഷൻ: Regular calibration (cell correction) is crucial for maintaining measurement accuracy. Perform calibration according to your application's requirements and industry standards.
- ഭവന വൃത്തിയാക്കൽ: പരസ്യം ഉപയോഗിച്ച് ഉപകരണ ഭവനം വൃത്തിയാക്കുകamp തുണി. ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
6. പ്രശ്നപരിഹാരം
നിങ്ങൾ നേരിട്ടേക്കാവുന്ന പൊതുവായ പ്രശ്നങ്ങളെ ഈ വിഭാഗം അഭിസംബോധന ചെയ്യുന്നു:
- ഉപകരണം ഓണാകുന്നില്ല:
- Check if batteries are correctly inserted and charged. Replace if necessary.
- If using an external power adapter, ensure it is properly connected and functional.
- കൃത്യമല്ലാത്ത വായനകൾ:
- Perform a cell correction (calibration) using fresh reference solutions.
- Clean the electrode thoroughly.
- Ensure the electrode is fully submerged and free of air bubbles during measurement.
- Verify that the temperature compensation setting is appropriate for your sample.
- No Data Logging:
- Check the device's memory capacity. Delete old data if full.
- Ensure data logging is activated and configured correctly in the device settings.
- ഡിസ്പ്ലേ പ്രശ്നങ്ങൾ:
- If the display is faint, replace the batteries.
- If the display shows error codes, consult the full manufacturer's manual for specific error interpretations.
For issues not covered here, please contact Greisinger customer support or refer to the comprehensive manufacturer's documentation.
7 സ്പെസിഫിക്കേഷനുകൾ
| പരാമീറ്റർ | മൂല്യം |
|---|---|
| ഉൽപ്പന്ന തരം | Combined Measurement Device |
| അളക്കൽ പ്രവർത്തനങ്ങൾ | Conductivity, Specific Resistance, Salinity, TDS, Temperature |
| Conductivity Measurement Range | 0.0 µS - 400.0 mS |
| Specific Resistance Range | 0.005 - 100.0 kΩ/cm |
| Salinity Measurement Range | 0.0 - 70.0 g/kg |
| TDS Measurement Range | 0 - 1999 mg/l |
| താപനില അളക്കൽ ശ്രേണി | -5 °C മുതൽ +100 °C വരെ |
| പ്രവർത്തന താപനില | -5 °C മുതൽ +80 °C വരെ |
| ഓട്ടോമാറ്റിക് താപനില നഷ്ടപരിഹാരം | അതെ |
| ഡിസ്പ്ലേ തരം | ഡിജിറ്റൽ |
| ഇലക്ട്രോഡ് മെറ്റീരിയൽ | Graphite (electrode), Epoxy (shaft) |
| ഇലക്ട്രോഡ് അളവുകൾ | Length approx. 120 mm, Ø approx. 12 mm |
| Cable Length (Electrode) | Approx. 1 meter (fixed connection) |
| ഇൻ്റർഫേസ് | സീരിയൽ |
| സംരക്ഷണ തരം | IP65 |
| അളവുകൾ (L x W x H) | 142 mm (H) x 71 mm (W) x 26 mm (D) |
| ഭാരം | 230 ഗ്രാം |
| നിർമ്മാതാവിൻ്റെ റഫറൻസ് | 603924 |
8. വാറൻ്റിയും പിന്തുണയും
Specific warranty details are not provided in the product data. For warranty claims, technical support, or service inquiries, please contact your retailer or the official Greisinger customer service directly. Keep your purchase receipt as proof of purchase.
നിർമ്മാതാവ്: ഗ്രീസിംഗർ
ASIN: B00UTKDSH8
Amazon.com.be-ൽ ആദ്യം ലഭ്യമായ തീയതി: മെയ് 7, 2022