1. ആമുഖം
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo JSWm 1AX-N self-priming electric water pump. Please read these instructions carefully before using the pump and keep this manual for future reference.
The Pedrollo JSWm 1AX-N is a self-priming electric pump designed for pumping water. This model is an updated version of the JSWM/1A series.
2 സുരക്ഷാ വിവരങ്ങൾ
മുന്നറിയിപ്പ്: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death.
- Always disconnect the pump from the power supply before performing any maintenance or installation.
- Ensure the electrical supply matches the pump's specifications (220-230V, 50Hz).
- The pump must be properly grounded to prevent electric shock.
- Do not operate the pump with damaged cables or plugs.
- Do not pump flammable, explosive, or corrosive liquids. This pump is designed for water only.
- പമ്പ് പ്രവർത്തിപ്പിക്കുമ്പോൾ കുട്ടികളെയും അനധികൃത വ്യക്തികളെയും അതിൽ നിന്ന് അകറ്റി നിർത്തുക.
- Install the pump in a well-ventilated area, protected from direct sunlight and freezing temperatures.
3. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Pedrollo JSWm 1AX-N is a robust self-priming pump. Key features include:
- Self-priming capability.
- Power: 0.75 kW (0.85 HP).
- Maximum flow rate: 55 liters/minute.
- Maximum head: 43 meters.
- Constructed with Noryl material.

Figure 1: Pedrollo JSWm 1AX-N Self-Priming Electric Water Pump. This image shows the overall view of the blue electric pump with its motor and pump housing.

Figure 2: Pedrollo JSWm 1AX-N Pump Rating Plate. This image displays the technical specifications label on the pump, including model number, power, voltage, frequency, and flow rates.
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
പമ്പിന്റെ പ്രകടനത്തിനും ദീർഘായുസ്സിനും ശരിയായ ഇൻസ്റ്റാളേഷൻ നിർണായകമാണ്.
- മൗണ്ടിംഗ്: Securely mount the pump on a stable, level surface. Ensure adequate ventilation around the motor.
- സക്ഷൻ ലൈൻ: Connect a rigid, airtight suction pipe to the pump's inlet. The suction line should be as short and straight as possible, with a foot valve at the end submerged in the water source. The pump can draw water from depths up to 9 meters.
- Delivery Line: Connect the delivery pipe to the pump's outlet. Install a check valve if the delivery line is long or has significant vertical lift.
- പ്രൈമിംഗ്: Before first use, or if the pump runs dry, fill the pump body completely with water through the priming port until it overflows. Replace the priming plug securely.
- ഇലക്ട്രിക്കൽ കണക്ഷൻ: Connect the pump to a dedicated 220-230V, 50Hz power supply. Ensure proper grounding. A qualified electrician should perform the electrical connection.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
- പ്രാരംഭ ആരംഭം: After priming, switch on the power supply. The pump should start drawing water and build pressure.
- തുടർച്ചയായ പ്രവർത്തനം: Monitor the pump for unusual noises or vibrations. Ensure a continuous water supply to prevent dry running.
- ഷട്ട് ഡൗൺ: Turn off the power supply to stop the pump.
കുറിപ്പ്: The pump is designed for continuous duty (thermally protected).
6. പരിപാലനം
Regular maintenance ensures optimal performance and extends the pump's lifespan.
- വൃത്തിയാക്കൽ: Periodically clean the pump exterior to prevent dirt buildup.
- ശീതകാലം: In freezing temperatures, drain all water from the pump and pipes to prevent damage. Store the pump in a frost-free environment.
- പരിശോധന: Regularly check for leaks, damaged cables, or unusual wear. Address any issues promptly.
- കാൽ വാൽവ്: Ensure the foot valve at the end of the suction line is clear of debris.
7. പ്രശ്നപരിഹാരം
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| പമ്പ് ആരംഭിക്കുന്നില്ല | No power supply; Motor overload; Damaged capacitor. | Check power connection and circuit breaker; Allow motor to cool; Consult a qualified technician. |
| പമ്പ് ഓടുന്നു, പക്ഷേ വെള്ളം ലഭിക്കുന്നില്ല. | Pump not primed; Air leak in suction line; Suction lift too high; Foot valve blocked. | Re-prime the pump; Check suction line for leaks; Reduce suction lift; Clean foot valve. |
| കുറഞ്ഞ ഒഴുക്ക് അല്ലെങ്കിൽ മർദ്ദം | Partial blockage in suction/delivery line; Worn impeller; Air in system. | Check and clear lines; Consult technician for impeller replacement; Re-prime pump. |
| അമിതമായ ശബ്ദം അല്ലെങ്കിൽ വൈബ്രേഷൻ | Cavitation (air in pump); Loose mounting; Worn bearings. | Ensure pump is fully primed and suction line is airtight; Secure mounting bolts; Consult a technician. |
8 സ്പെസിഫിക്കേഷനുകൾ
| സ്പെസിഫിക്കേഷൻ | മൂല്യം |
|---|---|
| മോഡൽ | JSWm 1AX-N |
| ബ്രാൻഡ് | Pedrollo |
| പവർ (എച്ച്പി) | 0.75 HP (P2 0.55 kW) |
| വാല്യംtage | 220-230 വി |
| ആവൃത്തി | 50 Hz |
| നിലവിലെ (ഇൻ) | 3.6 എ |
| Max Flow Rate (Q) | 55 l/min |
| Max Head (H) | 43 മീ |
| മെറ്റീരിയൽ | നോറിൽ |
| ഭാരം | 10 കി.ഗ്രാം (22.05 പൗണ്ട്) |
| സംരക്ഷണ ക്ലാസ് | IP X4 |
| ഇൻസുലേഷൻ ക്ലാസ് | F |
| പരമാവധി ദ്രാവക താപനില | 40 °C |
| ഡ്യൂട്ടി സൈക്കിൾ | Continuous duty (Thermally protected) |
9. വാറൻ്റിയും പിന്തുണയും
For warranty information and technical support, please refer to the official Pedrollo website or contact your authorized Pedrollo dealer. Keep your purchase receipt as proof of purchase.
Pedrollo is a manufacturer based in San Bonifacio (VR) Italy. Contact information may be available on the product's rating plate or official documentation.
കുറിപ്പ്: ഉൽപ്പന്ന വിശദാംശങ്ങളിൽ സ്പെയർ പാർട്സ് ലഭ്യത വിവരങ്ങൾ നൽകിയിട്ടില്ല.