Model: LEM-320

1. ആമുഖം

This manual provides essential information for the proper installation, operation, and maintenance of the Notifier LEM-320 Loop Expander Module. The LEM-320 is designed to expand the capacity of compatible fire alarm control panels by providing additional Signaling Line Circuits (SLCs).

2 സുരക്ഷാ വിവരങ്ങൾ

Always observe the following safety precautions during installation, operation, and maintenance of the LEM-320 module:

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Notifier LEM-320 is a Loop Expander Module designed to interface with a compatible Loop Control Module (LCM-320) to extend the system's capacity for addressable devices. It functions as a daughter board, providing additional even-numbered Signaling Line Circuits (SLCs) to the fire alarm control panel.

Notifier LEM-320 Loop Expander Module, top view

ചിത്രം 3.1: മുകളിൽ view of the Notifier LEM-320 Loop Expander Module, showing various integrated circuits and components.

Notifier LEM-320 Loop Expander Module, angled view

ചിത്രം 3.2: കോണാകൃതിയിലുള്ളത് view of the Notifier LEM-320 module, highlighting the component layout and connection points.

Notifier LEM-320 Loop Expander Module, bottom view

ചിത്രം 3.3: താഴെ view of the Notifier LEM-320 module, showing the circuit board traces and mounting points.

4. ഇൻസ്റ്റലേഷൻ

The LEM-320 module is designed to be mounted as a daughter board onto a compatible Notifier LCM-320 Loop Control Module. Follow these steps for proper installation:

  1. തയ്യാറാക്കൽ: Ensure all power to the fire alarm control panel is disconnected. Refer to the LCM-320 manual for specific power-down procedures.
  2. മൗണ്ടിംഗ് സ്ഥാനം കണ്ടെത്തുക: Identify the designated mounting headers on the LCM-320 board for the LEM-320 daughter board.
  3. Align Module: Carefully align the connectors on the LEM-320 with the corresponding headers on the LCM-320. Ensure correct orientation to prevent damage.
  4. സുരക്ഷിത മൊഡ്യൂൾ: Gently press the LEM-320 into place until it is firmly seated. Use any provided standoffs or screws to secure the module to the LCM-320, if applicable.
  5. കണക്ഷനുകൾ പരിശോധിക്കുക: Double-check that all connections are secure and that the module is properly seated.
  6. പവർ അപ്പ്: Restore power to the fire alarm control panel according to the manufacturer's instructions.
  7. സിസ്റ്റം കോൺഫിഗറേഷൻ: Configure the fire alarm control panel to recognize the newly installed LEM-320 module and its associated SLCs. Refer to the control panel's programming manual for detailed instructions.

കുറിപ്പ്: Improper installation can lead to system malfunction or damage. Always consult the specific documentation for the LCM-320 and the main fire alarm control panel.

5. ഓപ്പറേഷൻ

The Notifier LEM-320 Loop Expander Module operates as an integral part of the fire alarm control panel system. Once properly installed and configured with the LCM-320, it extends the system's capacity by providing additional Signaling Line Circuits (SLCs).

No direct user interaction is typically required with the LEM-320 module itself after initial installation and system configuration. Its function is to provide the necessary hardware expansion for the fire alarm system.

6. പരിപാലനം

The Notifier LEM-320 module is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection and adherence to general electronic component care practices are recommended:

ജാഗ്രത: Do not attempt to repair the module yourself. Refer all servicing to qualified Notifier service personnel.

7. പ്രശ്‌നപരിഹാരം

If the fire alarm system experiences issues related to SLC communication or device recognition after the LEM-320 installation, consider the following troubleshooting steps:

If issues persist, contact Notifier technical support or a certified fire alarm technician.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
മോഡൽ നമ്പർLEM-320 (Part Number: NLEM320)
നിർമ്മാതാവ്അറിയിപ്പ്
ഫംഗ്ഷൻLoop Expander Module for LCM-320
മൗണ്ടിംഗ്Daughter board to LCM-320
ഇനത്തിൻ്റെ ഭാരം2 പൗണ്ട്
ബാറ്ററികൾ ആവശ്യമാണ്ഇല്ല
ബാറ്ററികൾ ഉൾപ്പെടുത്തിയിട്ടുണ്ട്ഇല്ല
പാക്കേജ് അളവ്1

9. വാറൻ്റിയും പിന്തുണയും

For warranty information regarding the Notifier LEM-320 Loop Expander Module, please refer to the official Notifier warranty statement provided with your product or available on the Notifier webസൈറ്റ്. വാറന്റി നിബന്ധനകൾ സാധാരണയായി സാധാരണ ഉപയോഗത്തിലുള്ള മെറ്റീരിയലുകളിലെയും ജോലികളിലെയും വൈകല്യങ്ങൾ ഉൾക്കൊള്ളുന്നു.

For technical support, service, or to report issues, please contact your authorized Notifier distributor or Notifier technical support directly. Ensure you have your product model number (LEM-320) and any relevant system information ready when contacting support.

Notifier Contact Information:
Please visit the official Notifier webഏറ്റവും പുതിയ കോൺടാക്റ്റ് വിശദാംശങ്ങൾക്കും പിന്തുണാ ഉറവിടങ്ങൾക്കുമുള്ള സൈറ്റ്. www.notifier.com