1. പ്രധാന സുരക്ഷാ നിർദ്ദേശങ്ങൾ
Read all instructions carefully before installation and use. Failure to follow these instructions may result in serious injury or property damage. Keep this manual for future reference.
- Installation must be performed by qualified personnel in accordance with local safety regulations.
- Ensure the power supply is disconnected before performing any maintenance or repair work.
- Do not allow children to play near the gate opener or its controls.
- Keep hands and clothing clear of the gate's moving parts.
- Regularly inspect the gate opener for signs of wear or damage.
- The photo cells must be installed and maintained correctly to ensure proper safety operation.
2. ഉൽപ്പന്നം കഴിഞ്ഞുview
The Beninca Bull 424R is a robust 24VDC operator designed for intensive use with sliding gates. It features advanced electronic settings for precise control and reliable performance.
- Silent, Powerful, and Reliable: Engineered for consistent operation.
- LCD ഡിസ്പ്ലേ: Facilitates easy programming and configuration.
- Internal Limit-Switches: Provides accurate gate positioning.
- Easy Access to Board: Simplifies maintenance and adjustments.
- Multiple Feature Electronic Setting: Allows for customized operation.
- Digital Adjusting for Torque & Timing: Ensures smooth and safe gate movement.

Image 2.1: The complete Beninca Bull 424R gate opener kit, including the motor unit, gear racks, remote controls, receiver, photo cell, and warning light.
3. പാക്കേജ് ഉള്ളടക്കം
താഴെ പട്ടികപ്പെടുത്തിയിരിക്കുന്ന എല്ലാ ഘടകങ്ങളും നിങ്ങളുടെ പാക്കേജിൽ ഉണ്ടെന്ന് ഉറപ്പാക്കുക:
- 1x Beninca Bull 424R Gate Opener Motor Unit
- 1x റിസീവർ
- 2x റിമോട്ട് കൺട്രോളുകൾ
- 5x Gear Racks (39 inches each)
- 1x Photo Cell Set (Transmitter and Receiver)
- Mounting Hardware and Fasteners (not explicitly listed but implied for installation)

ചിത്രം 3.1: ക്ലോസ്-അപ്പ് view of the receiver unit and two remote controls, typically included in the kit.
4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Installation of the Beninca Bull 424R gate opener requires technical expertise. It is highly recommended that installation be performed by a qualified professional to ensure proper function and safety.
4.1. പ്രീ-ഇൻസ്റ്റലേഷൻ പരിശോധനകൾ
- Ensure the gate moves freely and smoothly without obstruction.
- Verify that the gate structure is sound and capable of supporting the opener's weight and forces.
- Confirm availability of a suitable power supply (24VDC).
4.2. Mounting the Motor Unit
- Position the motor unit on a stable, level concrete base adjacent to the gate.
- Secure the motor unit using appropriate anchor bolts.
- Ensure the motor's output pinion aligns correctly with the gate's gear rack.
4.3. Installing Gear Racks
- Attach the gear racks along the length of the gate, ensuring they are level and parallel to the gate's movement.
- Maintain a small clearance (approximately 1-2mm) between the rack and the motor pinion to allow for gate movement.
- Connect the 39-inch rack sections securely.
4.4. Wiring and Electrical Connections
- Connect the motor unit to the control board according to the wiring diagram provided in the full technical manual.
- Install the photo cells at appropriate heights and positions to detect obstructions. Wire them to the control board.
- Connect the receiver unit to the control board.
- എല്ലാ വൈദ്യുത കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും ഇൻസുലേറ്റ് ചെയ്തിട്ടുണ്ടെന്നും ഉറപ്പാക്കുക.
4.5. Programming the Remote Controls
The receiver unit allows for programming of the remote controls. Refer to the specific instructions for the receiver model (MRMINI1E or SLIM2E) for detailed programming steps.

Image 4.1: A Beninca remote control, used for operating the gate opener.
5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed and programmed, the Beninca Bull 424R gate opener is designed for straightforward operation.
5.1. Opening/Closing the Gate
- Press the programmed button on your remote control once. The gate will begin to open or close.
- Pressing the button again during movement will typically stop the gate. A third press will reverse its direction.
- The photo cells will detect any obstruction in the gate's path and automatically stop or reverse the gate's movement for safety.
5.2. മാനുവൽ റിലീസ്
In case of power failure or malfunction, the gate can be operated manually:
- Locate the manual release mechanism on the motor unit (refer to the full technical manual for exact location).
- Insert the provided key or handle and turn it to disengage the motor.
- ഗേറ്റ് ഇനി കൈകൊണ്ട് നീക്കാം.
- To re-engage, reverse the manual release procedure.
6. പരിപാലനം
പതിവ് അറ്റകുറ്റപ്പണികൾ നിങ്ങളുടെ ഗേറ്റ് ഓപ്പണറിന്റെ ദീർഘായുസ്സും സുരക്ഷിതമായ പ്രവർത്തനവും ഉറപ്പാക്കുന്നു.
- പ്രതിമാസ: Inspect the gate's movement for any stiffness or obstruction. Clean the gear rack and motor pinion.
- ത്രൈമാസിക: Check all mounting bolts and fasteners for tightness. Verify the proper functioning of the photo cells by obstructing their beam.
- വാർഷികം: Have a qualified technician inspect the entire system, including electrical connections, motor, and safety features.
- Keep the area around the gate opener clear of debris, vegetation, and water.
7. പ്രശ്നപരിഹാരം
If you encounter issues with your gate opener, consult the following common troubleshooting steps:
- Gate does not respond to remote:
- റിമോട്ട് കൺട്രോൾ ബാറ്ററി പരിശോധിക്കുക.
- Ensure the receiver is powered and correctly connected.
- Reprogram the remote control if necessary.
- Gate stops or reverses unexpectedly:
- ഗേറ്റിന്റെ പാതയിൽ തടസ്സങ്ങളുണ്ടോയെന്ന് പരിശോധിക്കുക.
- Clean photo cell lenses and ensure they are aligned.
- Inspect the gate for mechanical binding or damage.
- Motor runs but gate does not move:
- Verify the manual release mechanism is fully engaged.
- Inspect the gear rack and motor pinion for damage or misalignment.
- No power to the unit:
- മെയിൻ പവർ സപ്ലൈയും സർക്യൂട്ട് ബ്രേക്കറും പരിശോധിക്കുക.
- Inspect all electrical connections for loose wires.
If problems persist, contact a qualified technician or BENINCA customer support.
8 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | വിശദാംശങ്ങൾ |
|---|---|
| നിർമ്മാതാവ് | ബെനിൻക |
| ഭാഗം നമ്പർ | Beninca Bull 424R |
| മോഡൽ നമ്പർ | Beninca Bull 424R |
| വൈദ്യുതി വിതരണം | 24VDC (for intensive use) |
| നിയന്ത്രണ ബോർഡ് | എൽസിഡി ഡിസ്പ്ലേയുമായി സംയോജിപ്പിച്ചിരിക്കുന്നു |
| പരിധി സ്വിച്ചുകൾ | ആന്തരികം |
| റിമോട്ട് കൺട്രോൾ ഫ്രീക്വൻസി | 433 MHz (typical for MRMINI1E receiver) |
| ബാറ്ററികൾ ഉൾപ്പെടുത്തിയിട്ടുണ്ട് | ഇല്ല |
| ബാറ്ററികൾ ആവശ്യമാണ് | No (for main unit, remotes require small batteries) |
| ആദ്യം ലഭ്യമായ തീയതി | മെയ് 10, 2016 |
9. വാറൻ്റിയും പിന്തുണയും
For specific warranty information, please refer to the documentation provided with your purchase or contact BENINCA directly. Keep your proof of purchase for warranty claims.
For technical support, installation assistance, or spare parts, please contact your authorized BENINCA dealer or visit the official BENINCA webബന്ധപ്പെടാനുള്ള വിവരങ്ങൾക്കുള്ള സൈറ്റ്.