BELL 5874-5S

Hubbell 5874-5S Bell Cover and GFCI Receptacle Weatherproof Box Instruction Manual

മോഡൽ: 5874-5S

1. ഉൽപ്പന്നം കഴിഞ്ഞുview

The BELL 5874-5S is a 1-gang complete flip cover kit designed for outdoor electrical installations. It includes a self-test GFCI (Ground Fault Circuit Interrupter) receptacle, a weatherproof box, and a flip cover, all in a gray finish. This unit provides enhanced safety by protecting against electrical shocks in wet or damp സ്ഥാനങ്ങൾ.

പ്രധാന സവിശേഷതകൾ:

  • Self-test GFCI for continuous safety monitoring.
  • Rugged die-cast construction for durability.
  • State-of-the-art powder coat finish for maximum weatherability and scratch resistance.
  • Self-closing lids ensure weatherproof protection when the receptacle is not in use.
  • Includes gasket and mounting hardware for easy installation.
Hubbell 5874-5S Bell Cover and GFCI Receptacle Weatherproof Box, Grey, with cover open showing GFCI outlet

ചിത്രം 1: മുൻഭാഗം view of the Hubbell 5874-5S Weatherproof Box with the cover open, revealing the integrated GFCI receptacle.

2 സുരക്ഷാ വിവരങ്ങൾ

മുന്നറിയിപ്പ്: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that power is off before wiring! This device must be installed by a qualified electrician in accordance with all national and local electrical codes.

  • ഇൻസ്റ്റാളേഷൻ അല്ലെങ്കിൽ സർവീസ് ചെയ്യുന്നതിന് മുമ്പ് എല്ലായ്പ്പോഴും വൈദ്യുതി വിച്ഛേദിക്കുക.
  • Do not use if the product appears damaged.
  • എല്ലാ കണക്ഷനുകളും സുരക്ഷിതവും ശരിയായി ഇൻസുലേറ്റ് ചെയ്തതുമാണെന്ന് ഉറപ്പാക്കുക.
  • This product is designed for outdoor use and must be installed in a location protected from direct water spray, as per local codes.
  • പ്രൊപ്പോസിഷൻ 65 മുന്നറിയിപ്പ്: ഈ ഉൽപ്പന്നത്തിൽ കാലിഫോർണിയ സംസ്ഥാനത്തിന് ക്യാൻസറിനും ജനന വൈകല്യങ്ങൾക്കും അല്ലെങ്കിൽ മറ്റ് പ്രത്യുൽപാദന വൈകല്യങ്ങൾക്കും കാരണമാകുന്ന രാസവസ്തുക്കൾ അടങ്ങിയിരിക്കാം.

3. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

  1. ഇൻസ്റ്റലേഷൻ സൈറ്റ് തയ്യാറാക്കുക: Ensure the electrical box or mounting surface is clean, dry, and free of debris. Turn off power at the main circuit breaker.
  2. Mount the Weatherproof Box: Position the weatherproof box over the existing electrical box or mounting surface. Use the included mounting hardware to securely fasten the box. Ensure the gasket is properly seated between the box and the mounting surface to maintain a watertight seal.
  3. Wire the GFCI Receptacle: Connect the electrical wires to the GFCI receptacle terminals. Refer to the wiring diagram on the GFCI unit itself. Typically, the "LINE" terminals connect to the incoming power from the circuit breaker, and the "LOAD" terminals (if used) connect to downstream receptacles or devices that also require GFCI protection. Ensure proper polarity (hot, neutral, ground).
    തിരികെ view of the GFCI receptacle showing LINE and LOAD terminals

    ചിത്രം 2: പിൻഭാഗം view of the GFCI receptacle, indicating LINE and LOAD terminals for wiring.

  4. Install the GFCI into the Box: Carefully fold the wires and insert the GFCI receptacle into the weatherproof box opening. Secure it with the provided screws.
  5. Close the Flip Cover: Ensure the self-closing flip cover operates smoothly and provides a tight seal when closed.
  6. പവർ പുന ore സ്ഥാപിക്കുക: Turn on power at the main circuit breaker.

4. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

The integrated GFCI receptacle is designed for user safety. It continuously monitors the electrical current and will trip (shut off power) if it detects a ground fault, preventing electrical shock.

GFCI Self-Test Function:

This GFCI features an automatic self-test function. It periodically performs an internal test to ensure it is functioning correctly. If the GFCI fails the self-test, the indicator light will turn RED, and the unit will trip, indicating it needs replacement.

മാനുവൽ പരിശോധനയും പുനഃസജ്ജീകരണവും:

  • ടെസ്റ്റ് ബട്ടൺ: Press the "TEST" button (usually black or red) to manually trip the GFCI. This should cause the power to the receptacle to shut off.
  • റീസെറ്റ് ബട്ടൺ: After testing or if the GFCI has tripped, press the "RESET" button (usually red or white) to restore power. If the GFCI does not reset, or trips immediately, there may be a ground fault or wiring issue that needs to be addressed.

Self-Closing Lids:

The flip cover features self-closing lids that automatically close when a plug is removed. This ensures continuous weatherproof protection for the receptacle when it is not in use.

5. പരിപാലനം

  • പതിവ് വൃത്തിയാക്കൽ: Periodically clean the exterior of the weatherproof box with a damp തുണി. ഉരച്ചിലുകളുള്ള ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
  • Monthly GFCI Test: It is recommended to manually test the GFCI monthly by pressing the "TEST" button and then the "RESET" button. This verifies its proper operation.
  • കേടുപാടുകൾക്കായി പരിശോധിക്കുക: Regularly inspect the box and cover for any signs of physical damage, cracks, or wear. Replace the unit if any damage is observed.

6. പ്രശ്‌നപരിഹാരം

  • GFCI Will Not Reset:

    സാധ്യമായ കാരണം: A ground fault exists in the circuit or connected appliance. The GFCI is faulty. Power is off to the circuit.

    പരിഹാരം: Unplug all appliances from the GFCI and any downstream outlets. Try to reset. If it resets, plug appliances back in one by one to identify the faulty appliance. If it still won't reset, check the circuit breaker. If the breaker is on and no appliances are connected, the GFCI may be faulty and needs replacement. Observe the indicator light: if it's RED, replacement is necessary.

  • No Power to Receptacle:

    സാധ്യമായ കാരണം: GFCI is tripped. Circuit breaker is off. Loose wiring connection.

    പരിഹാരം: Press the "RESET" button on the GFCI. Check the circuit breaker in your electrical panel. Ensure all wiring connections are secure (only perform if power is off and you are qualified).

7 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
ഉൽപ്പന്ന തരം1-Gang, Complete Flip Cover Kit, Self Test GFCI, Flip Cover, Box, Receptacle
മോഡൽ നമ്പർ5874-5എസ്
ബ്രാൻഡ്ബെൽ
നിർമ്മാതാവ്ഹബ്ബൽ
നിറംചാരനിറം
മെറ്റീരിയൽഡൈ കാസ്റ്റ്
ഉൽപ്പന്ന അളവുകൾ3.14 x 7 x 8.5 ഇഞ്ച്
ഇനത്തിൻ്റെ ഭാരം5.44 ഔൺസ്
അനുയോജ്യമായ ഉപകരണങ്ങൾAll (standard electrical plugs)
പവർ പ്ലഗ് തരംType A - 2 pin (North American)
GFCI receptacle with dimensions indicating 4.3 inches or 10 cm in height

Figure 3: Dimensions of the GFCI receptacle component.

8. വാറൻ്റിയും പിന്തുണയും

This BELL product is manufactured by Hubbell and is designed for durability and performance. For specific warranty information or technical support, please refer to the documentation included with your purchase or visit the official BELL/Hubbell webസൈറ്റ്. വാറൻ്റി ക്ലെയിമുകൾക്കായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.

For further assistance, you may contact BELL customer service through their official channels.

അനുബന്ധ രേഖകൾ - 5874-5എസ്

പ്രീview Subaru Bell 412EPX Helicopter Specifications
Detailed specifications for the Subaru Bell 412EPX helicopter, including performance data, dimensions, avionics, and engine information. Explore the capabilities of this versatile aircraft.
പ്രീview Bell 407GXi 5G Radar Altimeter Filter Kit Installation Technical Bulletin
Technical Bulletin detailing the installation of the 5G Radar Altimeter Filter Retrofit Kit (407-704-039-101) for Bell 407GXi helicopters, ensuring compliance with FAA AD 2023-11-07.
പ്രീview Bell Smart Home Simon XT Battery Replacement Guide
Step-by-step instructions for replacing the battery in your Bell Smart Home Simon XT alarm system, including disposal and safety information.
പ്രീview ബെൽ 8025247 കോർഡ്‌ലെസ് ടെലിഫോൺ ഉപയോക്തൃ മാനുവൽ
ബെൽ 8025247 കോർഡ്‌ലെസ് ടെലിഫോണിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ മാനുവൽ, സജ്ജീകരണം, പ്രവർത്തനം, സവിശേഷതകൾ, ട്രബിൾഷൂട്ടിംഗ് എന്നിവ ഉൾക്കൊള്ളുന്നു. നിങ്ങളുടെ ബെൽ ഫോൺ എങ്ങനെ ഇൻസ്റ്റാൾ ചെയ്യാമെന്നും ഉപയോഗിക്കാമെന്നും പരിപാലിക്കാമെന്നും മനസ്സിലാക്കുക. സവിശേഷതകൾ ENERGY STAR® സർട്ടിഫിക്കേഷൻ (www.energystar.gov).
പ്രീview Bell Streamer Quick Start Guide
A quick start guide for the Bell Streamer, detailing its contents, remote control functions, setup instructions, and troubleshooting tips.
പ്രീview Guide de Création de Demandes DUSS pour Bell-Télébec
Ce guide détaillé explique le processus de création de demandes DUSS pour l'utilisation des structures de soutènement par Bell-Télébec, couvrant les procédures aériennes et souterraines.