The Sterling BB1260-12 Pro Batt Ultra Battery to Battery Charger is designed to efficiently charge your auxiliary battery bank while driving. This DC-powered smart charger is ideal for vehicles such as campers, boats, or vans, providing a significantly faster charge rate compared to a standalone alternator. It intelligently calculates the charging needs of the house bank and ensures optimal charging without risking the discharge of your starter battery.
The unit features a 4-stage battery charging process and offers 9 preset output charge profiles, with the option for a user-customizable profile to suit specific battery types and requirements.
2 പ്രധാന സവിശേഷതകൾ
- വിപുലമായ 4-എസ്tagഇ ചാർജിംഗ്: Charges batteries 5-20 times faster than a standard alternator.
- OEM Lock Function: Allows the installer to lock the unit's settings, preventing tampതെറ്റും ദുരുപയോഗവും.
- Automatic Regenerative Braking Friendly: The default mode does not require an ignition feed to operate.
- No Starter Battery Discharge Risk: Current is not drawn from the input battery to the output battery, except during the low voltage timer for regenerative braking mode.
- Versatile Battery Profiles: Includes 9 preset output charge profiles and a user-customizable option.
3 സുരക്ഷാ വിവരങ്ങൾ
WARNING: This product may contain materials cautioned by California Proposition 65. Always ensure proper ventilation and follow all local electrical codes during installation and operation.
Always disconnect power before making or breaking any electrical connections. Ensure all wiring is correctly sized for the current draw and properly fused. Do not expose the unit to water or excessive moisture.
4. ഇൻസ്റ്റലേഷൻ
The BB1260-12 charger is designed for simple connection between a starting battery and a house bank. It is crucial to ensure proper wiring and adequate ventilation for optimal performance and longevity.
അടിസ്ഥാന കണക്ഷൻ:
- Connect the input terminals of the BB1260-12 to your vehicle's starting battery.
- Connect the output terminals to your auxiliary (house) battery bank.
- എല്ലാ കണക്ഷനുകളും സുരക്ഷിതവും ശരിയായി ഇൻസുലേറ്റ് ചെയ്തതുമാണെന്ന് ഉറപ്പാക്കുക.
- Install the included temperature sensor (if applicable) on the house battery for accurate charging.

ചിത്രം 4.1: View of the Sterling BB1260-12 charger showing the input/output terminals and the overall robust casing.

Figure 4.2: Close-up of the temperature sensor and its connection, an important component for optimal battery charging.
സജീവമാക്കൽ മോഡുകൾ: The unit supports various activation modes:
- Automatic (Default): Operates on input voltage (13.3V / 26V on) and compensates for regenerative braking with a low voltagഇ ടൈമർ. ഇഗ്നിഷൻ ഫീഡ് ആവശ്യമില്ല.
- Ignition Feed: Requires an ignition feed to operate. Input voltage must be 13.3V and above.
- കുറഞ്ഞ വോളിയംtage (Regenerative Braking): Does not require an ignition feed. The unit stays on indefinitely, providing input voltage ഒരു നിശ്ചിത താഴ്ന്ന പരിധിക്ക് മുകളിൽ നിൽക്കുന്നു.
The OEM lock feature allows the installer to prevent tampering and misuse of the product by operators. By locking the BB, all previous settings are secured.
5. സജ്ജീകരണവും കോൺഫിഗറേഷനും
The BB1260-12 offers a user-friendly interface for selecting battery types and monitoring charge progress. The control panel features 'SETUP', 'ENTER', and 'SELECT' buttons.

ചിത്രം 5.1: മുൻഭാഗം view of the Sterling BB1260-12 charger, displaying the control panel with 'SETUP', 'ENTER', 'SELECT' buttons and the 'Preset Battery Options' table.

ചിത്രം 5.2: കോണാകൃതിയിലുള്ളത് view of the Sterling BB1260-12 charger, showing the top control panel with battery charge progress LEDs and configuration buttons.
Preset Battery Options:
The charger comes with 9 preset output charge profiles. These settings are designed to provide optimal charging for various battery chemistries. You can also set your own custom profile.
| ഓപ്ഷനുകൾ | Charge Volts | Boost Max (Mins) | Float Volts | Boost Max (Mins) |
|---|---|---|---|---|
| 1) GEL I | 14.10 | 120 | 13.70 | 480 |
| 2) AGM I | 14.40 | 120 | 13.70 | 480 |
| 3) Sealed | 14.40 | 120 | 13.70 | 480 |
| 4) GEL II | 14.20 | 120 | 13.70 | 480 |
| 5) AGM II | 14.60 | 120 | 13.70 | 480 |
| 6) തുറക്കുക | 14.80 | 120 | 13.70 | 480 |
| 7) De-sulfation | 15.50 | 30 | 13.80 | 240 |
| 8) LiFePO4 | 14.20 | 120 | 13.50 | 480 |
| 9) Custom | ഉപയോക്താവ് നിർവചിച്ചു | ഉപയോക്താവ് നിർവചിച്ചു | ഉപയോക്താവ് നിർവചിച്ചു | ഉപയോക്താവ് നിർവചിച്ചു |
Note: These settings are to be used as a guide. Always refer to your battery manufacturer's specifications for precise charging requirements. Incorrect settings can damage batteries.
കോൺഫിഗറേഷൻ ഘട്ടങ്ങൾ:
- Press the 'SETUP' button to enter configuration mode.
- Use the 'SELECT' button to cycle through the available battery profiles.
- Press 'ENTER' to confirm your selection.
- For custom profiles, follow the on-screen prompts to set specific voltage and time parameters.
6. ഓപ്പറേഷൻ
Once installed and configured, the BB1260-12 operates automatically. When your vehicle's alternator is running, the smart charger will begin charging the auxiliary battery bank. It will transition to float voltage once the battery is full, preventing overcharging.
The unit is designed to be 'Automatic Regenerative Braking Friendly', meaning it can operate effectively in modern vehicles with regenerative braking systems without requiring a separate ignition feed in its default mode.
7. പരിപാലനം
The Sterling BB1260-12 is designed for durability and requires minimal maintenance. To ensure optimal performance and longevity:
- യൂണിറ്റ് വൃത്തിയായി സൂക്ഷിക്കുക, പൊടിയും അവശിഷ്ടങ്ങളും ഒഴിവാക്കുക.
- എല്ലാ വയറിംഗ് കണക്ഷനുകളും സുരക്ഷിതമാണെന്നും തുരുമ്പെടുക്കലിൽ നിന്ന് മുക്തമാണെന്നും ഉറപ്പാക്കാൻ ഇടയ്ക്കിടെ പരിശോധിക്കുക.
- Ensure the unit has adequate ventilation to prevent overheating. The unit features thermal power reduction to manage heat.
- The unit is housed in a 100% safe plastic box, providing robust protection.
8. പ്രശ്നപരിഹാരം
If you encounter issues with your BB1260-12 charger, consider the following:
- പൊരുത്തമില്ലാത്ത ചാർജിംഗ്: Ensure all connections are tight and clean. Verify that the input voltage from the starter battery is sufficient (above 13.3V for automatic mode). If using an ignition feed, confirm the ignition signal is present.
- Unit Beeping: Refer to the LED status indicators on the unit. A beeping sound often indicates a warning or fault condition. Consult the detailed diagram for specific LED patterns and their meanings.
- Fan Running Continuously: The fan operates to cool the unit. If it runs for extended periods after the vehicle is off, check for proper ventilation around the unit. Ensure the unit is not in an excessively hot environment.
- No Output/Charging: Verify that the input battery is charged and providing sufficient voltage. Check all fuses in the charging circuit. Ensure the correct battery profile is selected for your auxiliary battery.
- Starter Battery Drain: The BB1260-12 is designed to prevent starter battery discharge. If this occurs, immediately check wiring for incorrect connections or short circuits. The unit should only draw current from the input battery during the low voltage timer for regenerative braking mode.

Figure 8.1: Detailed diagram from the Sterling BB1260-12 manual, illustrating activation modes, safety features, charging characteristics, and a comprehensive specification table.
9 സ്പെസിഫിക്കേഷനുകൾ
| സ്പെസിഫിക്കേഷൻ | മൂല്യം |
|---|---|
| ഉൽപ്പന്ന അളവുകൾ | 4.5 x 8 x 8 ഇഞ്ച് (4.5"D x 8"W x 8"H) |
| ഇനത്തിൻ്റെ ഭാരം | 1 പൗണ്ട് |
| Putട്ട്പുട്ട് വോളിയംtage | 12 വോൾട്ട് (DC) |
| നിറം | ചുവപ്പ്, വെള്ള |
| നിർമ്മാതാവ് | സ്റ്റെർലിംഗ് പവർ |
| ആദ്യ തീയതി ലഭ്യമാണ് | 6 മാർച്ച് 2018 |
| DC In (V) | DC Out (A) | ഭാരം (കിലോ) | L*W*H Dims | കോഡ് | |
|---|---|---|---|---|---|
| 12V | 30A ഇൻപുട്ട് | 1.2 | 190 x 160 x 50 | BB1230 | |
| 12V | 60A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB1260 | |
| 12V | 70A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB1270 | |
| 12V | 36V | 70A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB123670 |
| 12V | 48V | 70A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB124870 |
| 24V | 24V | 35A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB242435 |
| 24V | 12V | 35A ഇൻപുട്ട് | 1.4 | 190 x 160 x 70 | BB241235 |
| Remote w/ 10m cable | BBURC |
10. വാറൻ്റിയും പിന്തുണയും
For warranty information and technical support, please contact Sterling Power directly. Details can typically be found on their official webസൈറ്റ് അല്ലെങ്കിൽ ഉൽപ്പന്നം വാങ്ങിയ റീട്ടെയിലർ വഴി.
Please note that any extended protection plans offered by retailers (e.g., 2-Year or 3-Year Protection Plans) are separate from the manufacturer's warranty and are managed by the respective plan providers.