KAYSUN KSWP-80 Hn

Kaysun Aquatix 8 kW Pool Heat Pump KSWP-80 Hn User Manual

Model: KSWP-80 Hn

1. ആമുഖം

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Kaysun Aquatix 8 kW Pool Heat Pump, model KSWP-80 Hn. Please read this manual thoroughly before installation or use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2 സുരക്ഷാ വിവരങ്ങൾ

പ്രധാനപ്പെട്ട സുരക്ഷാ നിർദ്ദേശങ്ങൾ:

3. ഉൽപ്പന്നം കഴിഞ്ഞുview

The Kaysun Aquatix 8 kW Pool Heat Pump is designed to efficiently heat swimming pool water, extending your swimming season. It utilizes ambient air to transfer heat to your pool, offering an energy-efficient heating solution.

Kaysun Aquatix 8 kW Pool Heat Pump KSWP-80 Hn

Figure 1: Kaysun Aquatix 8 kW Pool Heat Pump KSWP-80 Hn. This image shows the compact, rectangular outdoor unit of the heat pump, typically white or light grey, with a fan grille on one side and a control panel on the front. Water inlet/outlet connections are usually located on the side or back.

പ്രധാന ഘടകങ്ങൾ:

4. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

Professional installation by a certified technician is highly recommended to ensure safety and optimal performance.

  1. സ്ഥാനം: Choose a well-ventilated outdoor location, away from direct sunlight, with sufficient clearance around the unit for airflow (typically 50cm on all sides and 100cm above). Avoid enclosed spaces or areas where exhaust air can be recirculated.
  2. മൗണ്ടിംഗ്: Place the unit on a solid, level base that can support its weight and minimize vibration.
  3. പ്ലംബിംഗ് കണക്ഷനുകൾ: Connect the heat pump to your pool's filtration system after the filter and before any chemical feeders. Ensure proper water flow direction. Use appropriate PVC fittings and sealants.
  4. ഇലക്ട്രിക്കൽ കണക്ഷനുകൾ: Connect the unit to a dedicated electrical circuit with appropriate overcurrent protection (circuit breaker) as specified in the technical specifications. All wiring must comply with local electrical codes.
  5. പ്രാരംഭ ആരംഭം: After all connections are secure and checked, ensure the pool pump is running and water is flowing through the heat pump before turning on the electrical supply to the unit.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Ensure your pool pump is running before operating the heat pump.

6. പരിപാലനം

പതിവ് അറ്റകുറ്റപ്പണികൾ മികച്ച പ്രകടനം ഉറപ്പാക്കുകയും നിങ്ങളുടെ ഹീറ്റ് പമ്പിന്റെ ആയുസ്സ് വർദ്ധിപ്പിക്കുകയും ചെയ്യുന്നു.

7. പ്രശ്‌നപരിഹാരം

ഉപഭോക്തൃ പിന്തുണയുമായി ബന്ധപ്പെടുന്നതിന് മുമ്പ്, വീണ്ടുംview ഈ പൊതുവായ പ്രശ്നങ്ങളും പരിഹാരങ്ങളും:

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
ഹീറ്റ് പമ്പ് ഓണാകുന്നില്ലNo power; tripped circuit breaker; unit switch off.Check power supply, reset breaker, ensure unit switch is on.
Pool not heating sufficientlyLow ambient temperature; dirty coils; insufficient run time; low water flow.Ensure coils are clean, allow more time, check pool pump and filter, verify water flow.
പിശക് കോഡ് പ്രദർശിപ്പിച്ചുപ്രത്യേക ആന്തരിക തകരാറ്.Note the error code and consult the full technical manual or contact a qualified technician.
അസാധാരണമായ ശബ്ദംDebris in fan; loose components; compressor issue.Turn off power, inspect for debris, tighten loose parts. If noise persists, contact service.

For issues not listed here or if solutions do not resolve the problem, please contact a qualified service technician.

8 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
ബ്രാൻഡ്കെയ്‌സുൻ
മോഡൽKSWP-80 Hn
ASINB071YNJDKK
നിർമ്മാതാവ്കെയ്‌സുൻ
ചൂടാക്കൽ ശേഷി8 kW
ശുപാർശ ചെയ്യുന്ന പൂൾ വോളിയം40 - 60 മീ³
ആദ്യം ലഭ്യമായ തീയതി21 ഫെബ്രുവരി 2020

9. വാറൻ്റിയും പിന്തുണയും

For warranty information, please refer to the warranty card included with your product or contact your authorized Kaysun dealer or the point of purchase. Keep your proof of purchase for warranty claims.

For technical support or service inquiries, please contact Kaysun customer service or your local distributor. Contact details can typically be found on the manufacturer's official webസൈറ്റ് അല്ലെങ്കിൽ നിങ്ങളുടെ വാങ്ങൽ ഡോക്യുമെന്റേഷനിൽ.

അനുബന്ധ രേഖകൾ - KSWP-80 Hn

പ്രീview Kaysun Compak Wall Hung Heat Pump Water Heater Installation and Owner's Manual
This manual provides detailed instructions for the installation, operation, and maintenance of Kaysun Compak KHP-08/80 ACS1, KHP-09/100 ACS1, and KHP-09/150 ACS1 wall-hung heat pump water heaters. It covers safety precautions, basic operation principles, installation procedures, trial-running, daily operation, troubleshooting common issues, and regular maintenance schedules.
പ്രീview Kaysun Wall-mounted Heat Pump Water Heater Technical Manual
Explore the comprehensive technical manual for Kaysun's Wall-mounted Type Heat Pump Water Heaters. This guide covers detailed specifications, installation, operation, and maintenance for models KHP-08/80 ACS1, KHP-09/100 ACS1, and KHP-09/150 ACS1, ensuring optimal performance and longevity.
പ്രീview Kaysun Aquantia HT HP Large Installation Manual
Comprehensive installation manual for the Kaysun Aquantia HT HP Large series heat pumps, including models KEM-50 DPS6, KEM-60 DPS6, and KEM-70 DPS6. Provides detailed guidance on installation procedures, safety precautions, electrical connections, and system setup for optimal performance.
പ്രീview Kaysun Multi Hybrid HR Outdoor Unit Installation and Owner's Manual
This manual provides comprehensive installation and operation instructions for the Kaysun Multi Hybrid HR Outdoor Unit, including safety precautions, wiring diagrams, and maintenance guidelines. It covers models KAM3HR-52 DR8 and KAM4HR-80 DR8.
പ്രീview Kaysun HR Outdoor Units Multisystem Service Manual
Comprehensive service manual for Kaysun HR Outdoor Units Multisystem, covering model numbers KAM3HR-52 DR8 and KAM4HR-80 DR8. Provides detailed technical information, troubleshooting guides, and maintenance procedures for HVAC professionals.
പ്രീview Kaysun ATW Heat Pump Installation Manual
This installation manual provides comprehensive instructions for the Kaysun ATW Heat Pump, covering safety precautions, unit installation, electrical wiring, controller setup, commissioning, and maintenance. It details procedures for handling flammable refrigerants like R290 and emphasizes safety measures for qualified installers.