Astralpool 65562

ആസ്ട്രൽ പൂൾ 65562 വിക്ടോറിയ പ്ലസ് സൈലന്റ് 1 സിവി സിംഗിൾ-ഫേസ് ഫിൽട്രേഷൻ പമ്പ് യൂസർ മാനുവൽ

1. ആമുഖം

1.1 ഉൽപ്പന്നം കഴിഞ്ഞുview

The Astral Pool Victoria Plus Silent pump, model 65562, is a high-performance, self-priming filtration pump designed for swimming pools. Engineered with thermoplastic materials, this pump offers enhanced durability and protection. Its design focuses on ease of use and maintenance, while operating at a reduced noise level, typically between 61 dBA and 70 dBA. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your pump.

Astral Pool Victoria Plus Silent pump, side view

ചിത്രം 1: വശം view of the Astral Pool Victoria Plus Silent pump.

1.2 സുരക്ഷാ വിവരങ്ങൾ

Before installing, operating, or performing maintenance on this pump, please read and understand all safety instructions. Failure to follow these instructions could result in serious injury or property damage.

  • ഇലക്ട്രിക്കൽ സുരക്ഷ: Always disconnect power to the pump before servicing. Electrical work should only be performed by a qualified electrician.
  • ജല സുരക്ഷ: Ensure proper water flow and avoid running the pump dry, as this can cause damage.
  • രാസ സുരക്ഷ: Be aware of pool chemicals and their interaction with pump components.
  • കുട്ടികൾ: പമ്പിൽ നിന്നും വൈദ്യുതി കണക്ഷനുകളിൽ നിന്നും കുട്ടികളെ അകറ്റി നിർത്തുക.

2. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

2.1 പമ്പ് പ്ലേസ്മെന്റ്

Position the pump on a solid, level surface, as close to the pool as possible to minimize friction losses in the suction line. Ensure adequate ventilation around the pump for cooling and easy access for maintenance.

2.2 പ്ലംബിംഗ് കണക്ഷനുകൾ

Connect the pump to your pool's filtration system using appropriate plumbing fittings. Ensure all connections are watertight to prevent leaks and maintain prime. Use thread sealant on all threaded connections.

2.3 ഇലക്ട്രിക്കൽ കണക്ഷൻ

This pump operates on 230V single-phase power. All electrical wiring must comply with local codes and regulations and should be performed by a licensed electrician. Ensure the pump is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD).

3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

3.1 പമ്പ് പ്രൈമിംഗ്

Before initial startup or after the pump has been drained, it must be primed. Open the pre-filter lid, fill the basket with water until it overflows, then replace the lid securely. Ensure all valves are open to allow water flow from the pool to the pump.

3.2 പമ്പ് ആരംഭിക്കുന്നു

Once primed, turn on the power to the pump. The pump should start drawing water and expel air from the system. If the pump does not prime within a few minutes, turn it off, re-prime, and check for air leaks in the suction line.

3.3 പ്രതിദിന പ്രവർത്തനം

Operate the pump for a sufficient duration each day to ensure proper filtration of your pool water. The exact duration depends on pool size, bather load, and environmental conditions. Consult your pool professional for recommended run times.

4. പരിപാലനം

4.1 Cleaning the Pre-Filter Basket

Regularly inspect and clean the pre-filter basket to remove debris. A clogged basket reduces pump efficiency and can lead to damage.

  1. പമ്പ് ഓഫ് ചെയ്ത് വൈദ്യുതി വിച്ഛേദിക്കുക.
  2. Close any necessary valves to prevent water flow from the pool.
  3. Unscrew the pre-filter lid.
  4. കൊട്ട നീക്കം ചെയ്ത് അവശിഷ്ടങ്ങൾ നീക്കം ചെയ്യുക.
  5. കൊട്ട നന്നായി വെള്ളത്തിൽ കഴുകുക.
  6. Inspect the lid O-ring for damage and lubricate if necessary.
  7. Replace the basket and secure the lid tightly.
  8. Re-prime the pump if necessary before restarting.
മുകളിൽ view of the Astral Pool Victoria Plus Silent pump showing the pre-filter lid

ചിത്രം 2: മുകളിൽ view showing the pre-filter lid for cleaning access.

4.2 ശീതകാലം

In regions subject to freezing temperatures, the pump must be properly winterized to prevent damage. Drain all water from the pump and plumbing lines. Store the pump in a dry, frost-free location if possible, or follow manufacturer guidelines for in-place winterization.

5. പ്രശ്‌നപരിഹാരം

This section addresses common issues you might encounter with your pump. For problems not listed here, or if solutions do not resolve the issue, contact a qualified service technician.

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
പമ്പ് ആരംഭിക്കുന്നില്ലNo power; tripped breaker; motor issueCheck power supply, reset breaker; consult electrician.
Pump runs but does not prime or loses primeLow water level; air leak in suction line; clogged pre-filter; closed valveCheck pool water level; inspect suction line for leaks; clean pre-filter basket; ensure all valves are open.
കുറഞ്ഞ ഒഴുക്ക് നിരക്ക്Clogged pre-filter; dirty main filter; restricted plumbingClean pre-filter basket; backwash or clean main filter; check plumbing for obstructions.
അമിതമായ ശബ്ദം അല്ലെങ്കിൽ വൈബ്രേഷൻAir leak; cavitation; worn bearings; loose mountingCheck for air leaks; ensure proper water flow; contact service for worn parts; tighten mounting bolts.

6 സ്പെസിഫിക്കേഷനുകൾ

Technical data for the Astral Pool Victoria Plus Silent 1 CV Single-Phase Filtration Pump, Model 65562:

ഫീച്ചർസ്പെസിഫിക്കേഷൻ
ബ്രാൻഡ്ആസ്ട്രൽപൂൾ
മോഡൽ നമ്പർ65562
വാല്യംtagഇ (വി)230
പവർ (സിവി)1
Capacity (l/h)16,000
Nominal Flow Rate (m³/h)16
മെറ്റീരിയൽപ്ലാസ്റ്റിക് (തെർമോപ്ലാസ്റ്റിക്)
പാക്കേജ് അളവുകൾ69 x 40 x 28 സെ.മീ
ഇനത്തിൻ്റെ ഭാരം10 കി.ഗ്രാം (22.05 പൗണ്ട്)
പവർ ഉറവിടംഎസി ഇലക്ട്രിക്

7. വാറൻ്റിയും പിന്തുണയും

Specific warranty details for the Astral Pool 65562 Victoria Plus Silent pump are not provided in this manual. For warranty information, please refer to the documentation included with your purchase or contact Astral Pool directly or your authorized dealer. For technical support or spare parts, please reach out to your supplier or an authorized service center.

അനുബന്ധ രേഖകൾ - 65562

പ്രീview AstralPool Niagara Pool Shower Installation Guide
Step-by-step instructions for installing the AstralPool Niagara outdoor shower, including parts, assembly diagrams, and technical specifications.
പ്രീview Astralpool Rousillon Automatic Pool Cover Installation and Maintenance Manual
A comprehensive guide for the installation and maintenance of the Astralpool Rousillon automatic pool cover, detailing components, civil engineering requirements, assembly steps, electrical installation, and safety features.
പ്രീview AstralPool E Series Saltwater Chlorinator Installation Manual
Comprehensive installation, operation, and maintenance guide for the AstralPool E Series Saltwater Chlorinator (E25/E35). Covers safety warnings, system overview, plumbing, electrical connections, water chemistry, operation modes, electrode maintenance, winterizing, and troubleshooting.
പ്രീview Astralpool Adjustable Bottom Nozzle Installation and Maintenance Manual
Comprehensive guide for installing and maintaining the Astralpool Adjustable Bottom Nozzle, covering product features, step-by-step installation, assembly, start-up, and technical specifications for optimal swimming pool cleaning.
പ്രീview ആസ്ട്രൽപൂൾ വിന്ററൈസർ കോപ്പർ ഫ്രീ: പൂൾ മെയിന്റനൻസ് ഗൈഡ്
ശൈത്യകാല പൂളിന്റെ പൂർണ്ണമായ അറ്റകുറ്റപ്പണികൾക്കായി ആസ്ട്രൽപൂൾ വിന്ററൈസർ കോപ്പർ ഫ്രീ ഉപയോഗിക്കുന്നതിനുള്ള സമഗ്ര ഗൈഡ്, ആൽഗകളുടെയും ബാക്ടീരിയകളുടെയും വളർച്ച തടയുന്നു. ഉൽപ്പന്ന ഗുണങ്ങൾ, സവിശേഷതകൾ, നിർദ്ദേശങ്ങൾ, ഡോസേജ് ശുപാർശകൾ എന്നിവ ഇതിൽ ഉൾപ്പെടുന്നു.
പ്രീview ASTRALPOOL INVERLONG: Winter Pool Maintenance Guide
Comprehensive guide to ASTRALPOOL INVERLONG, a winter pool maintenance product designed to keep water clear, prevent algae, and prepare your pool for the next season. Includes instructions, dosage, and properties.