NEC BE116506

NEC SL1100/SL2100 BE116506 Digital/Analog Station Card User Manual

മോഡൽ: BE116506

ബ്രാൻഡ്: എൻ‌ഇസി

1. ഉൽപ്പന്നം കഴിഞ്ഞുview

The NEC BE116506 Digital/Analog Station Card is designed for use with NEC SL1100 and SL2100 communication systems. This card provides essential interfaces for various station types and auxiliary functions, enhancing the versatility of your PBX system.

NEC BE116506 Digital/Analog Station Card

ചിത്രം 1.1: The NEC BE116506 Digital/Analog Station Card. This image displays the green circuit board with various electronic components, connectors, and the black faceplate with labeled ports for Trunks, ESI (1-4, 5-8), SLI (1-2), and RL/Audio connections.

പ്രധാന സവിശേഷതകൾ:

  • Provides interface for 8 digital stations and 2 analog stations.
  • Includes interfaces for Music-on-Hold or Background Music sources.
  • Supports External Paging Zone functionality.
  • Equipped with four 8-conductor interface jacks.
  • Two jacks for 8 digital stations.
  • One jack for 2 analog stations or Doorboxes.
  • One jack for Music-on-Hold/Background Music input, External Paging Zone output, and two relay circuit connections.
  • Relay circuits support Door-strike control (when analog ports are used for Doorboxes), control for Music-on-Hold/Background Music sources, and control of External Paging Equipment.
  • Installs in universal slots 1-3 of Main or Expansion Chassis.
  • Allows addition of one 3-Port CO Trunk Daughter Board (3COIDB) or one PRI Daughter Board (1PRDB).
  • Maximum of 3 cards per Main or Expansion Chassis.
  • Maximum of 9 cards per system.

2. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും

This section provides guidelines for the proper installation of the BE116506 Digital/Analog Station Card into your NEC SL1100 or SL2100 system. Ensure the system is powered off before beginning installation.

2.1. Card Placement

  • The BE116506 card must be installed in universal slots 1-3 of either the Main Chassis or an Expansion Chassis.
  • A maximum of three BE116506 cards can be installed per Main or Expansion Chassis.
  • The total number of BE116506 cards across the entire system should not exceed nine.

2.2. Daughter Board Installation (Optional)

The BE116506 card supports the addition of a daughter board for expanded functionality:

  • One 3-Port CO Trunk Daughter Board (3COIDB) can be added.
  • Alternatively, one PRI Daughter Board (1PRDB) can be added.
  • Refer to the specific daughter board's manual for detailed installation instructions.

2.3. കേബിളുകൾ ബന്ധിപ്പിക്കുന്നു

The card is equipped with four 8-conductor interface jacks on its faceplate. Connect your system's cabling as follows:

  • Digital Stations: Use the two dedicated jacks for connecting up to 8 digital stations.
  • Analog Stations/Doorboxes: Use the single dedicated jack for connecting up to 2 analog stations or Doorboxes.
  • Auxiliary Connections: The remaining jack is for Music-on-Hold/Background Music input, External Paging Zone output, and relay circuit connections.

Warning: Ensure all connections are secure and correctly aligned to prevent damage to the card or connected equipment. Consult a qualified technician if you are unsure about any installation steps.

3. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

Once the BE116506 card is installed and the system is powered on, its interfaces become active. Configuration of specific features will typically be done through the PBX system's programming interface.

3.1. Digital and Analog Station Usage

  • Digital stations connected to the card will function according to your system's programming for digital extensions.
  • Analog stations (e.g., single-line phones, fax machines) or Doorboxes connected will operate based on their assigned extension numbers and system configurations.

3.2. Music-on-Hold / Background Music

Connect your Music-on-Hold or Background Music source to the designated input jack. The system's programming will determine when and how this audio is played to callers or internal users.

3.3. External Paging Zone

Connect your external paging equipment to the designated output jack. The PBX system's programming will allow users to initiate pages through this zone.

3.4. Relay Circuit Control

The two relay circuit connections provide control for external devices:

  • Door-strike Control: If Doorboxes are connected to the analog ports, these relays can be programmed to control door-strike mechanisms, allowing users to remotely open doors.
  • Music-on-Hold/Background Music Source Control: The relays can be used to activate or deactivate the external audio source connected for Music-on-Hold or Background Music.
  • External Paging Equipment Control: Control external paging amplifiers or other equipment related to the paging zone.

Refer to your NEC SL1100/SL2100 system's programming manual for detailed instructions on configuring these features.

4. പരിപാലനം

The NEC BE116506 Digital/Analog Station Card is designed for reliable operation with minimal maintenance. Adhering to the following guidelines can help ensure its longevity:

  • പരിസ്ഥിതി: Ensure the PBX system chassis, where the card is installed, is kept in a clean, dry, and temperature-controlled environment. Avoid excessive dust, humidity, and extreme temperatures.
  • വൃത്തിയാക്കൽ: Periodically inspect the card and chassis for dust accumulation. If necessary, gently clean with compressed air. Do not use liquid cleaners directly on the card.
  • കണക്ഷനുകൾ: Ensure all cable connections to the card remain secure. Loose connections can lead to intermittent service or performance issues.
  • ഫേംവെയർ: Keep your NEC SL1100/SL2100 system firmware updated as recommended by NEC. This ensures optimal compatibility and performance of all installed components, including the station card.

Caution: Do not attempt to repair the card yourself. Unauthorized repairs can void the warranty and may cause further damage.

5. പ്രശ്‌നപരിഹാരം

If you encounter issues with your BE116506 Digital/Analog Station Card, consider the following basic troubleshooting steps:

  • No Dial Tone/Service:
    • Verify the card is properly seated in its slot.
    • Check all connected cables for secure connections.
    • Confirm the station is correctly programmed in the PBX system.
    • Test with a known working phone or device.
  • Music-on-Hold/Paging Not Working:
    • Ensure the audio source is connected and functioning.
    • Verify the external paging equipment is powered on and connected.
    • Check the PBX system's programming for Music-on-Hold/Paging settings.
  • Relay Circuits Not Activating:
    • Confirm the external device (e.g., door-strike, amplifier) is correctly wired to the relay contacts.
    • Verify the relay control is properly programmed within the PBX system.
  • സിസ്റ്റം പിശകുകൾ: If the PBX system displays errors related to the card, consult your system administrator or NEC technical support.

For complex issues, it is recommended to contact a certified NEC technician or your system vendor for assistance.

6 സ്പെസിഫിക്കേഷനുകൾ

ഫീച്ചർവിശദാംശങ്ങൾ
ഉൽപ്പന്ന അളവുകൾ10 x 2 x 6 ഇഞ്ച്
ഇനത്തിൻ്റെ ഭാരം1 പൗണ്ട്
ASINB072Q75ZRQ
ഇനം മോഡൽ നമ്പർBE116506
നിർമ്മാതാവ്NEC
ആദ്യ തീയതി ലഭ്യമാണ്ജൂൺ 3, 2017
അനുയോജ്യതNEC SL1100, NEC SL2100 PBX Systems
Station Interfaces8 Digital Stations, 2 Analog Stations
ഓക്സിലറി ഇന്റർഫേസുകൾMusic-on-Hold/Background Music Input, External Paging Zone Output, 2 Relay Circuits
Slot RequirementUniversal slots 1-3 (Main or Expansion Chassis)
Daughter Board Support1x 3-Port CO Trunk Daughter Board (3COIDB) or 1x PRI Daughter Board (1PRDB)
Max per Chassis3
Max per System9

7. പ്രധാനപ്പെട്ട വിവരങ്ങൾ

7.1. Legal Disclaimer (Proposition 65 Warning)

ഈ ഉൽപ്പന്നത്തിൽ കാൻസർ, ജനന വൈകല്യങ്ങൾ അല്ലെങ്കിൽ മറ്റ് പ്രത്യുൽപാദന തകരാറുകൾ എന്നിവയ്ക്ക് കാരണമാകുന്ന കാലിഫോർണിയ സംസ്ഥാനത്തിന് അറിയപ്പെടുന്ന രാസവസ്തുക്കൾ അടങ്ങിയിരിക്കുന്നു.

8. വാറൻ്റിയും പിന്തുണയും

8.1. വാറൻ്റി വിവരങ്ങൾ

Specific warranty details for the NEC BE116506 Digital/Analog Station Card are typically provided at the point of purchase or through official NEC documentation. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the documentation included with your product or contact your NEC dealer.

8.2. സാങ്കേതിക പിന്തുണ

For technical assistance, installation support, or troubleshooting beyond the scope of this manual, please contact your authorized NEC dealer or a certified PBX system technician. You may also visit the official NEC webപിന്തുണാ ഉറവിടങ്ങൾക്കും ബന്ധപ്പെടാനുള്ള വിവരങ്ങൾക്കുമുള്ള സൈറ്റ്.

NEC Official Webസൈറ്റ്: www.nec.com

അനുബന്ധ രേഖകൾ - BE116506

പ്രീview Setting Time and Date on NEC SL2100/SL1100 Phones
A guide on how to set the time and date using the phone keypad on NEC SL2100 and SL1100 phone systems.
പ്രീview NEC SL2100 മൾട്ടിലൈൻ ടെർമിനൽ ഉപയോക്തൃ ഗൈഡ്
NEC SL2100 മൾട്ടിലൈൻ ടെർമിനലിനായുള്ള സമഗ്രമായ ഉപയോക്തൃ ഗൈഡ്, ഇൻസ്റ്റാളേഷൻ, പ്രവർത്തനം, കോൾ കൈകാര്യം ചെയ്യൽ, വോയ്‌സ് മെയിൽ, സിസ്റ്റം അഡ്മിനിസ്ട്രേഷൻ സവിശേഷതകൾ എന്നിവ ഉൾക്കൊള്ളുന്നു.
പ്രീview NEC DSX-80/160 ഹാർഡ്‌വെയർ മാനുവൽ - സാങ്കേതിക ഗൈഡ്
NEC DSX-80/160 ടെലിഫോൺ സിസ്റ്റത്തിനായുള്ള സമഗ്രമായ ഹാർഡ്‌വെയർ മാനുവൽ, സർവീസ് ഉദ്യോഗസ്ഥർക്കും ഉപയോക്താക്കൾക്കുമുള്ള ഘടകങ്ങൾ, ഇൻസ്റ്റാളേഷൻ, കോൺഫിഗറേഷൻ, സ്പെസിഫിക്കേഷനുകൾ എന്നിവ വിശദമായി പ്രതിപാദിക്കുന്നു.
പ്രീview NEC SL2100 മൾട്ടി-ലൈൻ ടെർമിനൽ ക്വിക്ക് യൂസർ ഗൈഡ് | പ്ലെക്സസ് കമ്മ്യൂണിക്കേഷൻസ്
പ്ലെക്സസ് കമ്മ്യൂണിക്കേഷൻസിൽ നിന്നുള്ള കോളുകൾ വിളിക്കൽ, കോളുകൾ കൈകാര്യം ചെയ്യൽ, വോയ്‌സ്‌മെയിൽ, ഹാൻഡ്‌സെറ്റ് സവിശേഷതകൾ എന്നിവയെക്കുറിച്ചുള്ള നിർദ്ദേശങ്ങൾ നൽകുന്ന NEC SL2100 മൾട്ടി-ലൈൻ ടെർമിനലിനായുള്ള ഒരു ദ്രുത ഉപയോക്തൃ ഗൈഡ്.
പ്രീview NEC ഇലക്ട്ര എലൈറ്റ് IPK സവിശേഷതകളും സ്പെസിഫിക്കേഷനുകളും മാനുവൽ - സമഗ്ര ഗൈഡ്
NEC ഇലക്ട്ര എലൈറ്റ് IPK ടെലികമ്മ്യൂണിക്കേഷൻ സിസ്റ്റത്തിന്റെ സമഗ്രമായ സവിശേഷതകളും വിശദമായ സ്പെസിഫിക്കേഷനുകളും പര്യവേക്ഷണം ചെയ്യുക. ബിസിനസുകൾക്കായുള്ള ഇൻസ്റ്റാളേഷൻ, പ്രോഗ്രാമിംഗ്, പ്രവർത്തന വശങ്ങൾ എന്നിവ ഈ മാനുവലിൽ ഉൾക്കൊള്ളുന്നു.
പ്രീview NEC SL2100 Quick Install Guide for Multiline IP Terminals
This guide provides step-by-step instructions for the installation, configuration, and basic operation of NEC SL2100 Multiline IP Terminals, including models IP7WW-8IPLD-C1, ITY-6D, and ITY-8LDX.