ആമുഖം
The Intermatic DT101 Digital Time Switch is designed to provide precise, automated control over electrical circuits. This electronic time switch offers advanced features compared to traditional mechanical timers, including up-to-the-minute programming, battery backup for power outages, and automatic Daylight Saving Time adjustments. It supports up to 28 programmable events and operates on a standard 24-hour cycle, making it ideal for daily repeating schedules.

ചിത്രം 1: മുൻഭാഗം view of the Intermatic DT101 Digital Time Switch, showing the digital display, control buttons, and battery compartment.
പ്രധാനപ്പെട്ട സുരക്ഷാ വിവരങ്ങൾ
മുന്നറിയിപ്പ്: തീപിടുത്തമോ വൈദ്യുതാഘാതമോ ഉണ്ടാകാനുള്ള സാധ്യത. Installation and servicing of this product must be performed by a qualified electrician in accordance with all national and local electrical codes. Always disconnect power at the circuit breaker or disconnect switch before installing or servicing the unit. This enclosure does not provide grounding between conduit connections. If metal conduit is used, you must also install grounding type bushings and jumper wires.
- ഈ ഉപകരണം ഇൻസ്റ്റാൾ ചെയ്യുന്നതിനോ ഉപയോഗിക്കുന്നതിനോ മുമ്പായി എല്ലാ നിർദ്ദേശങ്ങളും വായിക്കുക.
- വൈദ്യുതി വിതരണം വോള്യവുമായി പൊരുത്തപ്പെടുന്നുണ്ടെന്ന് ഉറപ്പാക്കുകtage requirements of the timer (120-277 VAC, 50/60 Hz).
- Do not exceed the maximum load ratings of the switch.
- This device is intended for indoor use only unless installed in a suitable outdoor enclosure.

Figure 2: The Intermatic DT101 unit with its cover open, revealing the internal components, wiring terminals, and printed safety warnings on the inside of the door.
സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Proper installation is critical for the safe and effective operation of your DT101 Digital Time Switch. Follow these steps carefully:
- പവർ വിച്ഛേദിക്കുക: Before beginning any installation, ensure that power to the circuit where the timer will be installed is completely disconnected at the main circuit breaker or fuse box. Verify with a voltagഇ ടെസ്റ്റർ.
- മൗണ്ടിംഗ്: Mount the timer enclosure securely to a wall or suitable surface using appropriate fasteners. Ensure it is level and accessible for wiring and programming.
- ബാറ്ററി ഇൻസ്റ്റാളേഷൻ: Install the two (2) AAA batteries (required, not included) into the battery compartment. This provides backup power for settings during power outages.
- വയറിംഗ്: Connect the electrical wires to the appropriate terminals inside the timer. The DT101 supports 120-277 VAC. Refer to the wiring diagram printed inside the unit's door for correct connections (Line 1, Load 1, Neutral, Ground). Ensure all connections are tight and secure.
- പ്രാരംഭ പവർ-അപ്പ്, റീസെറ്റ്: After wiring, close the enclosure door. Restore power to the circuit. The unit should power on. If the display is blank or unresponsive, or if the AUTO function does not work as expected, perform a reset. To reset, press the പുനഃസജ്ജമാക്കുക button. Some users have reported needing to press പ്രവേശിക്കുക ഒപ്പം പുനഃസജ്ജമാക്കുക simultaneously if the unit does not function correctly after initial power-up. Ensure the device is ON before connecting the main power.
- വാല്യംtagഇ തിരഞ്ഞെടുക്കൽ: If applicable, ensure the selector switch inside the unit is set to the correct input voltage (120V, 208V, 240V, or 277V) matching your electrical supply.

ചിത്രം 3: ക്ലോസപ്പ് view of the internal wiring and circuit board of the Intermatic DT101, illustrating the connection points for electrical installation.
പ്രവർത്തന നിർദ്ദേശങ്ങൾ
The DT101 allows for flexible programming of up to 28 ON/OFF events. Follow these steps to set the time and program schedules:
നിലവിലെ സമയവും തീയതിയും ക്രമീകരിക്കുന്നു
- അമർത്തുക മോഡ് button repeatedly until "SET CLOCK" appears on the display.
- ഉപയോഗിക്കുക + ഒപ്പം - മണിക്കൂർ ക്രമീകരിക്കാൻ ബട്ടണുകൾ അമർത്തുക, തുടർന്ന് നൽകുക/അടുത്തത്.
- മിനിറ്റ് ക്രമീകരിക്കുക, തുടർന്ന് അമർത്തുക നൽകുക/അടുത്തത്.
- Adjust the year, then press നൽകുക/അടുത്തത്.
- Adjust the month, then press നൽകുക/അടുത്തത്.
- Adjust the day, then press നൽകുക/അടുത്തത്.
- The display will return to the current time. The DT101 automatically adjusts for Daylight Saving Time.
Programming ON/OFF Events
- അമർത്തുക മോഡ് button repeatedly until "SET PROGRAM" appears.
- The display will show "PROG 1 ON". Use + ഒപ്പം - to set the desired ON time for the first event. Press നൽകുക/അടുത്തത്.
- Select the days of the week for this ON event (e.g., MO TU WE TH FR SA SU for everyday, or specific days). Press നൽകുക/അടുത്തത്.
- The display will show "PROG 1 OFF". Set the desired OFF time for the first event. Press നൽകുക/അടുത്തത്.
- Select the days of the week for this OFF event. Press നൽകുക/അടുത്തത്.
- Repeat steps 2-5 for additional ON/OFF events (up to 28 total). To exit programming, press മോഡ്.
മാനുവൽ അസാധുവാക്കൽ
The DT101 allows for temporary or permanent manual override of the programmed schedule:
- താൽക്കാലിക അസാധുവാക്കൽ: അമർത്തുക ഓൺ/ഓഫ് button once. The output will switch to the opposite state (ON if OFF, OFF if ON) until the next programmed event.
- Permanent Override: അമർത്തിപ്പിടിക്കുക ഓൺ/ഓഫ് button for 3 seconds. The output will remain in its current state, ignoring all programmed events, until the button is pressed and held again for 3 seconds to return to automatic mode.
മെയിൻ്റനൻസ്
The Intermatic DT101 Digital Time Switch is designed for minimal maintenance. However, periodic checks can ensure its longevity and reliable operation:
- ബാറ്ററി മാറ്റിസ്ഥാപിക്കൽ: The two AAA batteries provide backup for settings during power outages. Replace them every 3-5 years, or if a low battery indicator appears on the display. Always replace batteries with the unit powered off at the circuit breaker.
- വൃത്തിയാക്കൽ: Clean the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- കണക്ഷൻ പരിശോധന: Periodically, with power disconnected, inspect the wiring connections to ensure they remain tight and free from corrosion.
ട്രബിൾഷൂട്ടിംഗ്
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Display is blank or unit is unresponsive. | No power to the unit; incorrect wiring; dead batteries. | Check circuit breaker. Verify wiring connections. Replace AAA batteries. |
| Timer does not follow programmed schedule (stays ON/OFF). | Unit is in permanent manual override mode; incorrect initial setup sequence; programming error. | അമർത്തിപ്പിടിക്കുക ഓൺ/ഓഫ് button for 3 seconds to return to AUTO mode. Ensure batteries were installed and unit was ON before connecting main power. Perform a full reset (പുനഃസജ്ജമാക്കുക ബട്ടൺ, അല്ലെങ്കിൽ പ്രവേശിക്കുക + പുനഃസജ്ജമാക്കുക if needed) and re-program. Double-check programmed times and days. |
| സമയമോ തീയതിയോ തെറ്റാണ്. | Time not set correctly; power outage without battery backup. | Re-set current time and date. Ensure batteries are installed and functional. |
| Cannot program events. | Unit not in programming mode; maximum events reached. | അമർത്തുക മോഡ് until "SET PROGRAM" appears. The unit supports up to 28 events. |
സ്പെസിഫിക്കേഷനുകൾ
- മോഡൽ നമ്പർ: DT101D89
- ഇൻപുട്ട് വോളിയംtage: 120-277 VAC, 50/60 Hz (selectable)
- സ്വിച്ച് തരം: SPST (സിംഗിൾ പോൾ സിംഗിൾ ത്രോ)
- Ampകോപം: 20 Amp
- Number of Events: Up to 28 ON/OFF events
- ബാറ്ററി ബാക്കപ്പ്: 2 x AAA ബാറ്ററികൾ (ഉൾപ്പെടുത്തിയിട്ടില്ല)
- അളവുകൾ: 3.2"D x 8"W x 5.4"H (8.1 സെ.മീ D x 20.3 സെ.മീ W x 13.7 സെ.മീ H)
- ഭാരം: 2.4 പൗണ്ട് (1.09 കി.ഗ്രാം)
- നിറം: ചാരനിറം
- ഫീച്ചറുകൾ: To-the-minute accuracy, Temporary/Permanent manual override, Automatic Daylight Saving Time adjustment.
വാറൻ്റിയും പിന്തുണയും
For warranty information and technical support, please contact Intermatic customer service or visit the official Intermatic webവാറന്റി ക്ലെയിമുകൾക്കുള്ള വാങ്ങലിന്റെ തെളിവായി നിങ്ങളുടെ വാങ്ങൽ രസീത് സൂക്ഷിക്കുക.
ഇൻ്റർമാറ്റിക് Webസൈറ്റ്: www.intermatic.com