1. ആമുഖം
The Astralpool Micro pH Pacific is an automatic peristaltic dosing pump designed for precise pH regulation in swimming pools. This device helps maintain optimal water balance by automatically adding pH minus solution, ensuring a clean and safe swimming environment. It is suitable for pools up to 100 m³. This manual provides essential information for the safe and effective installation, operation, and maintenance of your pH regulator.
2 സുരക്ഷാ വിവരങ്ങൾ
Please read all safety instructions carefully before installing or operating the device. Failure to follow these instructions may result in injury or damage to the equipment.
- Ensure the power supply is disconnected before any installation or maintenance work.
- Handle pH solutions with care. Always wear appropriate personal protective equipment, such as gloves and eye protection.
- Keep the device and chemicals out of reach of children and pets.
- Install the unit in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
- ഏതെങ്കിലും ഇൻസ്റ്റാളേഷൻ ഘട്ടങ്ങളെക്കുറിച്ച് നിങ്ങൾക്ക് ഉറപ്പില്ലെങ്കിൽ, യോഗ്യതയുള്ള ഒരു പ്രൊഫഷണലിനെ സമീപിക്കുക.
3. പാക്കേജ് ഉള്ളടക്കം
ഇൻസ്റ്റാളേഷനുമായി മുന്നോട്ടുപോകുന്നതിനുമുമ്പ് എല്ലാ ഘടകങ്ങളും പാക്കേജിൽ ഉണ്ടെന്ന് ഉറപ്പാക്കുക.

ചിത്രം 3.1: കഴിഞ്ഞുview of the Astralpool Micro pH Pacific regulator and its complete set of accessories.
- Peristaltic Dosing Pump Micro pH Pacific (Main Unit)
- pH അന്വേഷണം
- സക്ഷൻ സ്ട്രൈനർ
- ഡിസ്ചാർജ് ട്യൂബ്
- സക്ഷൻ ട്യൂബ്
- പ്രോബ് ഹോൾഡർ
- വാൾ മൗണ്ടിംഗ് കിറ്റ്
- ഇഞ്ചക്ഷൻ വാൽവ്
- pH Calibration Solutions
- Clamp Collars (x2, Ø50)

ചിത്രം 3.2: The main unit of the Astralpool Micro pH Pacific regulator.

ചിത്രം 3.3: The pH probe, essential for measuring water acidity.

ചിത്രം 3.4: Bottle of pH calibration solution for accurate sensor readings.

ചിത്രം 3.5: Components of the wall mounting kit for securing the unit.

ചിത്രം 3.6: Suction tube for drawing pH minus solution.

ചിത്രം 3.7: Discharge tube for injecting pH minus solution into the pool.

ചിത്രം 3.8: Injection valve for controlled release of solution.

ചിത്രം 3.9: രണ്ട് clamp collars (Ø50) for securing tubes.
4 സ്പെസിഫിക്കേഷനുകൾ
| ഫീച്ചർ | സ്പെസിഫിക്കേഷൻ |
|---|---|
| ഉൽപ്പന്ന തരം | പെരിസ്റ്റാൽറ്റിക് ഡോസിംഗ് പമ്പ് |
| നിയന്ത്രണ തരം | pH Minus Only |
| പരമാവധി പൂൾ വോളിയം | 100 m³ |
| Casing സംരക്ഷണം | IP65 |
| അളവുകൾ (L x H x D) | 115 x 183 x 109 മിമി |
| വൈദ്യുതി വിതരണം | 230V |
| പരമാവധി ഫ്ലോ റേറ്റ് | 1.6 l/h |
| പരമാവധി മർദ്ദം | 1 ബാർ |
| അളക്കൽ ശ്രേണി | 0 മുതൽ 9.90 വരെ pH |
| കാലിബ്രേഷൻ തരം | സെമി ഓട്ടോമാറ്റിക് |
| മോഡൽ നമ്പർ | 500425 |
5. സജ്ജീകരണവും ഇൻസ്റ്റാളേഷനും
Follow these steps carefully to install your Astralpool Micro pH Pacific regulator.
- Mounting the Regulator: Install the Micro pH Pacific regulator on a wall using the provided wall mounting kit. Choose a location that is dry, easily accessible, and close to the pool's filtration system.
- ബന്ധിപ്പിക്കുന്ന ട്യൂബുകൾ:
- Connect the suction strainer to one end of the suction tube. Place the strainer into the container of pH minus solution.
- Connect the other end of the suction tube to the inlet port of the dosing pump.
- Connect the discharge tube to the outlet port of the dosing pump.
- Install the injection valve into the pool's return line (after the filter and heater, if applicable) using one of the Ø50 clamp collars. Connect the discharge tube to this injection valve.
- pH Probe Installation:
- Attach the probe holder to the pool's circulation pipe using the second Ø50 clamp കോളർ.
- Carefully insert the pH probe into the probe holder, ensuring it is immersed in the pool water flow according to recommended depth guidelines.
- Connect the pH probe cable to the designated port on the Micro pH Pacific unit.
- പവർ കണക്ഷൻ: Connect the dosing pump to a 230V power supply. Ensure the connection is secure and protected from moisture.
- പ്രാരംഭ കാലിബ്രേഷൻ: Before first use, the pH probe must be calibrated.
- Refer to the detailed calibration instructions in the operating section of this manual.
- Use the provided pH calibration solutions for accurate calibration.
6. പ്രവർത്തന നിർദ്ദേശങ്ങൾ
Once installed and calibrated, the Astralpool Micro pH Pacific operates semi-automatically to maintain your pool's pH level.
- പവർ ഓൺ: Turn on the power to the dosing pump. The LED display will show the current pH reading.
- Setting the Desired pH: Use the "SET" button on the unit to adjust your desired pH level. The recommended pH range for swimming pools is typically between 7.0 and 7.4.
- Monitoring pH: The unit continuously monitors the pool's pH level. If the pH rises above your set point, the pump will automatically inject pH minus solution until the desired level is reached.
- Calibration Procedure (Semi-Automatic):
- Prepare the pH calibration solutions (e.g., pH 7.0 and pH 4.0).
- Remove the pH probe from the pool water and rinse it with distilled water.
- Immerse the probe in the first calibration solution (e.g., pH 7.0). Press the "CAL" button and follow the on-screen prompts. Wait for the unit to stabilize and confirm the reading.
- Rinse the probe again and immerse it in the second calibration solution (e.g., pH 4.0). Repeat the calibration process.
- Once calibration is complete, return the probe to the pool water.
- Regular calibration (e.g., monthly or as recommended by the manufacturer) is crucial for accurate pH readings.
- Refilling pH Minus Solution: Regularly check the level of your pH minus solution container. Refill as needed to ensure continuous operation.
7. പരിപാലനം
Regular maintenance ensures the longevity and accurate performance of your pH regulator.
- pH Probe Cleaning: Periodically clean the pH probe to remove any deposits or algae that may affect its accuracy. Use a soft brush and a mild cleaning solution specifically designed for pH probes. Rinse thoroughly with distilled water after cleaning.
- ട്യൂബ് പരിശോധന: Inspect the suction and discharge tubes for any signs of wear, cracks, or blockages. Replace them if necessary.
- Peristaltic Pump Tube: The peristaltic pump tube (inside the main unit) is a wear part and may need replacement over time, depending on usage. Consult the manufacturer's guidelines for replacement intervals.
- പൊതുവായ ശുചീകരണം: Keep the exterior of the dosing pump clean and free from dust and chemical spills.
- ശീതകാലം: If you winterize your pool, ensure the dosing pump and probe are properly drained, cleaned, and stored in a frost-free environment.
8. പ്രശ്നപരിഹാരം
This section addresses common issues you might encounter with your pH regulator.
| പ്രശ്നം | സാധ്യമായ കാരണം | പരിഹാരം |
|---|---|---|
| Inaccurate pH Readings |
|
|
| Pump Not Dosing |
|
|
| pH Level Not Changing |
|
|
9. വാറൻ്റിയും പിന്തുണയും
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. AstralPool products are designed for reliability, but should you encounter any issues not covered in this manual, please contact AstralPool customer support or your authorized service center for assistance.
ബ്രാൻഡ്: ആസ്ട്രൽപൂൾ
മോഡൽ: Micro pH Pacific (500425)